Majestic Appliances 3105, 3112 Minimum Clearances to Combustible Materials, Hearth Requirements

Page 8

Vermont Castings Jefferson Vent Free Gas Heater

Clearance Requirements

Minimum Clearances to

Combustible Materials

Maintain clearance, (empty space), between combus- tible materials and the heater as specified.

Alcove Clearances

 

B

B

D

 

 

A

ST103

C

A: Ceiling .................. 27Z\x” C:

Rear Wall ................... 4”

B: Side Wall .............. 4” D: Max. Alcove Depth ..... 48”

Fig. 6

Minimum wall clearances.

 

Hearth Requirements

The JUVS must be installed on rigid flooring. If the appliance is installed on any combustible surface other than wood flooring, such as carpet or tile, a metal or wood panel must be installed to extend the full length and width of the unit.

W A R N I N G

Do not install this heater in a bathroom or bedroom.

Installation of this heater must conform with Local Codes or in the absence of Local Codes, with the National Fuel Gas Code, ANSI Z223.1.

This heater creates warm air currents. These currents move heat to wall surfaces next to the heater. Installing the heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air such as tobacco smoke exist, may discolor walls.

Do not use a blower insert, heat exchanger insert or other accessory not approved with this heater.

Mantel Clearance

12”

10”

8”

12” 6” 10”

4”

Wall

8”

6” 2”

4” 1” 2”

1”

Stove

FP599b

Fig. 7 Mantel clearance at 45°.

NOTE: Mantel clearances will apply to an alcove installation.

8

Image 8
Contents Jefferson Table of Contents Juvs Specifications AccessoriesCarbon Monoxide Poisoning MAY Lead to Death Safety InformationHigh Altitude Derating Vent Free Features General InformationUnpack the Stove To remove the packaged log set from the fireboxInstallation Requirements Provide for Adequate VentilationUnusually Tight Construction Determine If You Have a Confined or Unconfined SpaceSupplementing ventilation air Minimum Clearances to Combustible Materials Hearth RequirementsAssembly Procedures Optional Fan Kit Installation 2960/FK28Aged Logs Install the Log SetConnect the Gas Supply Line Install ON/OFF Switch Thermostat Connection optionalPilot and Burner Inspection OperationYour First Fire Correct Pilot Flame. *JUVSM pilots do not have Thermopile To Turn Off Gas To Heater What to do if YOU Smell GASMaintenance Firebox Cleaning and InspectionCleaning Procedure Care of Cast IronIgnitor Electrode sparks, but Pilot does not light TroubleshootingNo spark at pilot when Ignitor is operated Flame goes out while in operation Pilot lights but Main Burner does notMain Burner shuts off and Pilot Odor During Operation Models OnlyJefferson Vent Free Gas Heater Juvs Warranty Vermont Castings Majestic Products Company