Vermont Castings Jefferson Vent Free Gas Heater
Operation
Your First Fire
Read these instructions carefully and familiarize yourself with the burner controls of this heater.
The JUVSR uses a Honeywell control valve that allows thermostatic, on/off switch regulation and has a sepa- rate Piezo ignition button. (Fig. 19 or 20)
The JUVSM is equipped with an SIT control valve for manual use only.
Locate the Pilot assembly to the right behind the burner. (Fig. 21) Follow the lighting instructions on page 14 exactly.
For the first fire, allow the stove to operate continuously for six hours without using the fan. During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within a few hours or so, however, you can open a window to provide plenty of fresh air to alleviate this condition.
Pilot and Burner Inspection
Each time you light your heater, check that the pilot flame and burner flame pattern are as shown in Figures 23 and 24. If flame patterns are incorrect, turn the heater off. See Troubleshooting, page 16.
Do not operate the heater until the pilot flame is correct.
Follow regular maintenance procedures as described on page 15.
|
| Piezo Ignitor |
| |
|
|
|
| TH |
|
|
| PILOT | OFF |
|
|
| TP | |
| I | L |
| |
|
|
| ||
| H O | ON | TPTH | |
|
|
| ||
|
|
|
| PILOT ADJ |
|
| Regulator |
|
|
|
| Control Knob |
| Gas |
HV104 |
|
|
| |
|
|
| Control Knob | |
Fig. 19 | Valve controls. |
|
|
Piezo Ignitor
LO
PILOT
OFF
HI
ST573
Fig. 20 SIT control valve.
| Natural Pilot |
| LP Pilot |
| ST232 |
Fig. 21 | Pilot assembly location. |
12