Majestic Appliances 3100, 3112, 3111 General Information, Vent Free Features, Unpack the Stove

Page 5

Vermont Castings Jefferson Vent Free Gas Heater

General Information

Vent Free Features

The JUVS Gas Heater is an unvented gas appliance tested and listed to the ANSI standard Z21.11.2.2000. The Vent Free Gas Heater is configured to use Natural Gas, (JUVSRN, JUVSMN ) or Propane (JUVSRP, JUVSMP). Because these heaters are clean-burning and highly energy-efficient, no venting system is required.

The JUVS is shipped fully assembled with the exception of the log set. The log set is assembled during installation.

The JUVS is equipped with a Honeywell control valve that allows thermostatic control, on/off switch or a remote switch (not supplied).

The JUVS model incorporates variable regulators that allow you to adjust burner heat output between HIGH, (28,000 BTU), and LOW, (20,000 BTU). See the Operation Section for details.

The standing pilot incorporates an Oxygen Depletion System (ODS/pilot) which shuts off gas flow to the burner in the event that sufficient fresh air becomes unavailable for continued safe operation.

Safety

Screen

Rear Log

Bracket

Pilot Hood &

Pilot

Rheostat

Bracket

OFF/ON/Pilot

Control Knob

Piezo Ignitor

Variable

Supply

 

Regulator

Line Inlet

 

 

Gas Valve

ST100

Fig. 2 JUVS gas heater. Valve may be different.

Unpack the Stove

Remove the stove assembly from the shipping carton and inspect it for loose or damaged parts. Do not install this appliance if any parts are loose or if there is any visual or suspected damage resulting from shipping or handling. Report damage to your dealer/distributor immediately. The log set is packaged in the box shipped inside the firebox.

To remove the packaged log set from the firebox:

Lift the stove front up and then swing the bottom out and away to disengage it from the stove body. (Fig. 3) Cut the wire tie securing the screen.

Remove the screen frame. (Fig. 4)

Remove box and set aside.

Contact your dealer if the burner is loose or damaged in any way.

ST229b

Fig. 3 Remove stove front.

Screen Hooks

ST208b

Fig. 4 Lift screen from firebox.

5

Image 5
Contents Jefferson Table of Contents Accessories Juvs SpecificationsCarbon Monoxide Poisoning MAY Lead to Death Safety InformationHigh Altitude Derating General Information Vent Free FeaturesUnpack the Stove To remove the packaged log set from the fireboxProvide for Adequate Ventilation Installation RequirementsUnusually Tight Construction Determine If You Have a Confined or Unconfined SpaceSupplementing ventilation air Hearth Requirements Minimum Clearances to Combustible MaterialsOptional Fan Kit Installation 2960/FK28 Assembly ProceduresAged Logs Install the Log SetConnect the Gas Supply Line Thermostat Connection optional Install ON/OFF SwitchPilot and Burner Inspection OperationYour First Fire Correct Pilot Flame. *JUVSM pilots do not have Thermopile What to do if YOU Smell GAS To Turn Off Gas To HeaterFirebox Cleaning and Inspection MaintenanceCleaning Procedure Care of Cast IronIgnitor Electrode sparks, but Pilot does not light TroubleshootingNo spark at pilot when Ignitor is operated Flame goes out while in operation Pilot lights but Main Burner does notMain Burner shuts off and Pilot Models Only Odor During OperationJefferson Vent Free Gas Heater Juvs Warranty Vermont Castings Majestic Products Company