Majestic Appliances 3107, 3112, 3111, 3101 Install ON/OFF Switch, Thermostat Connection optional

Page 11

Vermont Castings Jefferson Vent Free Gas Heater

 

5

 

4

 

ST224

 

Lava Rock

Fig. 15

Install lava rock and upper logs.

 

ST225

Fig. 16

Completed log installation.

Install ON/OFF Switch

(R Models only)

The switch assembly parts are found in the parts bag.

1.Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud. (Fig. 17)

2.Run wires down back of stove, under bottom of rear shroud to valve.

3.Attach wires to valve terminals. (Fig. 18)

Switch

Existing

Assem-

Holes

bly

 

Screws

 

 

ST315

Fig. 17 Attach switch assembly to rear shroud.

 

TH

TP

TPTH

ST228

Fig. 18 Attach switch wires to valve.

Thermostat Connection (optional)

(R Models only)

Use only a thermostat rated for 500 millivolts. Do not use low voltage (24V) thermostats.

Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation.

Thermostat Wire / Gauge

Maximum Run

18

40 feet

20

25 feet

22

16 feet

1.Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors.

2.Connect the thermostat wires to the valve. (Fig. 18)

11

Image 11
Contents Jefferson Table of Contents Accessories Juvs SpecificationsCarbon Monoxide Poisoning MAY Lead to Death Safety InformationHigh Altitude Derating To remove the packaged log set from the firebox Vent Free FeaturesGeneral Information Unpack the StoveDetermine If You Have a Confined or Unconfined Space Installation RequirementsProvide for Adequate Ventilation Unusually Tight ConstructionSupplementing ventilation air Hearth Requirements Minimum Clearances to Combustible MaterialsOptional Fan Kit Installation 2960/FK28 Assembly ProceduresAged Logs Install the Log SetConnect the Gas Supply Line Thermostat Connection optional Install ON/OFF SwitchPilot and Burner Inspection OperationYour First Fire Correct Pilot Flame. *JUVSM pilots do not have Thermopile What to do if YOU Smell GAS To Turn Off Gas To HeaterCare of Cast Iron MaintenanceFirebox Cleaning and Inspection Cleaning ProcedureIgnitor Electrode sparks, but Pilot does not light TroubleshootingNo spark at pilot when Ignitor is operated Flame goes out while in operation Pilot lights but Main Burner does notMain Burner shuts off and Pilot Models Only Odor During OperationJefferson Vent Free Gas Heater Juvs Warranty Vermont Castings Majestic Products Company