Louisville Tin and Stove BFT301, BFT201, BFT102, BFT202, BFT101, BFT302 NA Gastural, Feet Pipe Length

Page 7

BTUTOTAL -REQUIRE

FROMTS ANSINFPN54, .Z223 T1 DETERMINEO PROPER.MENTS SUPPLGAS LINEY REQUIREDSIZE OT TSUPPOR

SEE CHARFOLLOWING

NA GASTURAL

5.0 orpsig andLess Pressurea ofDrop .0 Inch5 aterW .Column

inPipe FeetCubic Gasof Hourper Gasfor ofPressures

Maximum ofCapacity

(Based on a 0.60 Specific Gravity Gas)

 

 

 

200

 

 

 

175

 

 

 

150

 

 

 

125

 

 

 

100

 

 

 

90

 

 

 

FEET

 

 

80

PIPE,

 

 

70

LENGTH OF

 

 

60 50

 

 

 

40

 

 

 

30

 

 

 

20

 

 

,Diameter

10

Internal

Inches

Nominal Pipe Iron

Size,

Inches

8

19

35

72

135

280

430

800

1280

2280

4600

9

20

37

77

145

300

460

850

1370

2450

5000

10

22

40

84

160

325

500

950

1500

2650

5500

11

24

44

93

175

360

550

1020

1650

2950

6000

12

27

50

103

195

400

620

1150

1850

3250

6700

13

29

53

110

205

430

650

1220

1950

3450

7200

14

31

57

118

220

460

690

1300

2050

3700

7500

15

33

61

125

240

490

750

1400

2250

3900

8100

16

36

66

138

260

530

810

1520

2400

4300

8800

18

40

73

151

285

580

900

1680

2650

4750

7.9

20

45

82

170

320

660

990

1900

3000

5300

10900

24

52

97

200

375

770

1180

2200

3520

6250

12800

29

65

120

250

465

950

1460

2750

4350

7.7

15800

43

95

175

360

680

1400

2100

3950

6300

11000

23000

364.0

493.0

622.0

824.0

049.1

38.1

61.1

067.2

469.2

068.3

026.4

¼½¾1-1-12-234 3/81/41/2”1/2

Range

65,000

5 8 Feet

Furnace

 

26

Feet

 

 

First Stage

Regulator

SelectionTubing andPipe *

feet) +65,000+35,000 90@ 4table 38,000 (usefeet +=200,000 84= lengthpiping demandb, toa Total From

200,000

1”use .pipe

338,000= .BTU/hr

35,000+

.tubing 7/8”or pipe¾” use

65,000+

BTU/hr;

38,000

138,000

= =

demand

 

c,

 

to

 

b

 

From

 

From c to d, demand = 65,000 + 35,000

Clothes

Dryer

Water

Heater

Second Stage

Regulator

.tubing ¾”

.tubing 5/8”

orpipe ¾”use BTU/hr;100,000 =

orpipe ½”use BTU/hr;35,000 =

 

demande, tod From

35,000

38,000

From b to f, demand = 200,000 BTU/hr; use 1” .pipe

3,

 

 

or

 

 

1

 

 

Table

 

 

(use

½”

 

PSIG

pipe,

 

is10

use ½”

 

regulatorsetting

= 338,000 BTU/hr;

pipe.

=26feet;firststage

From aa to a, demand

tubing, or ½” T plastic

length

 

 

piping

 

 

stage

 

 

first

feet)

Total

@30

 

 

.P

.tubing 5/8”or

 

.L

.tubing ¾”or

stage-two the

pipe½” use

pipe½” use

forrequired

BTU/hr;38,000

BTU/hr;65,000

tubingor piping

=demand g,to cFrom

=demand h,to dFrom

of .shown . sizesthe installation 2Example Determine Gas

@

 

 

 

 

 

 

 

piping length = 58 feet (use table 4,

= 338,000 BTU/hr; use 1” pipe.

= 138,000 BTU/hr; use ¾” pipe or 7/8”

= 100,000 BTU/hr; use ½” pipe or ¾”

= 35,000 BTU/hr; use ½” pipe or ½”

= 200,000 BTU/hr; use ¾” pipe.

= 38,000 BTU/hr; use ½” pipe or 5/8”

 

Total second stage

60 feet). From a to b, demand

From b to c, demand

tubing. From c to d, demand

tubing. From d to e, demand

tubing. From b to f, demand

From c to g, demand

tubing.

*Information from - REGO PRODUCTS “LP GAS SERVICEMAN’S MANUAL” SEE FOLLOWING PAGE FOR PIPE SIZING CHARTS FOR PROPANE GAS.

Page 7

Image 7
Contents What to do if YOU Smell GAS Blue Flame Vent Free HeatersIllustrated Parts BREAKDOWN……… Tools & Additional SUPPLIES… IntroductionOperation Room Heater SpecificationsSafety Instructions Introduction CONT’DFresh AIR for COMBUSTION, Ventilation and Heat Distribution Location InstallationTools and Additional Supplies Required ClearancesFeet Pipe Length NA GasturalPropane GAS Installing VF-FSK Floor Base KIT Installing Heater Wall Mount BFT10Wall Mount Natural GAS GAS ConnectionBurner Orifice Specific ElevationFor Your Safety Read Before Lighting Proper Operation ODS / Pilot Flame ODS/PILOT MaintenanceCabinet Main BurnerBlower Instructions Symptom Possible Causes Corrective Action Trouble Shooting GuideBFT101 BFT102 BFT201 BFT202 BFT301 BFT302 Model Included NAT. GAS L.P. GASModel Numbers NAT Tampering is Dangerous Critical Safety Points to RememberTable a Limited Warranty

BFT301, BFT302, BFT102, BFT201, BFT202 specifications

Louisville Tin and Stove has established itself as a reputable name in the world of heating solutions, offering a range of innovative products designed for both efficiency and comfort. Among their notable offerings are the BFT101, BFT302, BFT201, BFT102, and BFT202 models. Each of these units boasts unique features, technologies, and characteristics that cater to various customer needs.

The BFT101 is designed with compact living spaces in mind. It offers an intuitive user interface that ensures easy operation. Its efficient heat exchange system allows for rapid heating, providing warm air quickly and effectively. The BFT101's sleek design fits seamlessly into any room, making it an aesthetic addition to home décor while ensuring functionality.

The BFT302 takes efficiency a notch higher with advanced thermal technology. This model is equipped with a dual-fuel capability, allowing users to switch between different energy sources, such as gas or electric. The BFT302's smart thermostat provides precise temperature control, optimizing energy consumption without compromising comfort. Additionally, it comes with a built-in safety mechanism that ensures the unit operates seamlessly and safely.

For larger spaces, the BFT201 model stands out with its powerful heating capabilities. This unit features a robust construction designed to withstand prolonged usage while delivering consistent heat throughout the area. The BFT201 is also compatible with smart home technology, allowing users to control the heating remotely, a feature that provides convenience and enhances user experience.

The BFT102 is favored for its versatility. It operates efficiently in various environments, whether it’s a residential setting or a commercial space. Equipped with multiple heating settings, the BFT102 can easily adapt to changing temperature needs. Its low emissions make it an eco-friendly choice, aligning with sustainability goals without sacrificing performance.

Lastly, the BFT202 offers a combination of elegance and innovation. This model is equipped with advanced filtration technology that not only heats efficiently but also cleans the air, ensuring a healthier environment. The BFT202 features a whisper-quiet operation, making it suitable for bedrooms and offices where noise reduction is important.

In summary, the Louisville Tin and Stove BFT series, including the BFT101, BFT302, BFT201, BFT102, and BFT202, provides a comprehensive range of heating solutions that cater to a variety of spaces and customer preferences. Each model is designed with state-of-the-art technology, focusing on energy efficiency, safety, and user convenience, making them excellent choices for modern heating needs.