Figure 18.

Wall Vent Terminal /

Overhang Clearances

21/2

12 ” 64mm

305 3” mm 76mm

Variable Vent Restriction

Vent restriction is accomplished by sliding a restric- tor panel over the combustion air intake ports located at the back of the firebox. See Fig 19. The panel is set in a fully open position at the factory. Use the Vent Window diagrams in Figs. 12-13 as a starting point to determine the best restriction setting. Follow these steps to adjust the restriction as necessary:

1.Remove the Controls Panel to access the adjust- ment lever at the rear of the valve compatment. Simply loosen the two wingnuts that secure the panel to the cabinet floor and pull the panel forward. You do not need to disconnect any wires.

2.Locate the vent restriction wingnut protruding from the firebox floor at the rear of the valve compartment. Loosen the wingnut and push the lever to the left to increase restriction in one inch increments, e.g: 1 inch travel = 1/3 closed position.

The ideal restrictor setting for a particular vent system will vary depending on the specific installa- tion characteristics. Once the fireplace is operating, further restrictor adjustment may be necessary to obtain the best performance. See the Operation chapter of this manual for more information.

Fully Closed

2/3 Closed

1/3 Closed

Full Open

 

BLOWER

 

BURNER

 

IGNITOR

ON

HI

 

MANUAL

 

M

 

OFF

 

 

HI

AUTO

OFF

 

LO

 

LO

 

 

 

Figure 19. Vent restrictor adjustment.

Fireplace Installation

Optional Blower

Install the optional Blower (155630) before installing the gas supply line.

Power Requirement

The blower must be electrically grounded in accor- dance with local codes or, in the absence of local codes, with the current NFPA 70- National Electrical Code or CSA C22.1-Canadian Code.

Athree-prong (grounding) power supply plug is included for protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. DO NOT CUT OR REMOVE

THE GROUNDING PRONG FROM THE PLUG.

Blower Function

In the Auto mode, the blower is controlled by a heat activated switch (snapstat) that will turn the fan on and off as the firebox heats and cools. Use the Manual mode to over-ride the snapstat. If the blower is not needed, place the blower control switch in the OFF position and the snapstat will not function.

CAUTION: Always unplug the Blower when performing any routine service to the Acadia gas fireplace.

Installation

1.Loosen the two wingnuts that secure the Control Panel to the fireplace floor. Pull the panel forward and swing it to the right to access the rear of the cabinet. Do not disconnect any wires.

2.Insert a rubber grommet at each corner of the Base Plate as shown in fig. 20.

3.Engage the Blower unit base with the four studs at the rear of the fireplace cabinet floor. See fig. 21.

4.Insert the Snapstat into the slot in the Snapstat Bracket and, using the M6 nuts and 10 mm socket, attach the Control Switch / Snapstat Bracket to the two studs protruding from the firebox floor. See fig. 22.

5.Connect the Blower Wire harness to the switch connector at the back of the Control Panel and two other leads to either terminal on the snapstat.

6.Run the power cord to the duplex receptacle in the side of the cabinet. Gather slack cord into the side cavity, away from the plumbing and other wiring. Reposition and secure the Control Panel.

12

Image 12
Contents Installation and Operation Instructions Jøtul GZ 550 DV Acadia Direct Vent Gas FireplaceWelcome to Jøtul Table of Contents Specifications Test StandardsInput Rates Suggested Tools for Installation and Service General InformationSafety Information Installation RequirementsPlacement and Framing Parallel InstallationCabinet Dimensions Hearth Protection Facing and Clearance RequirementsMantel and Trim Clearance Vent Requirements Venting GuidelinesVertical Termination Horizontal TerminationHorizontal Termination Clearance Heightin FeetFireplace Installation Optional BlowerVariable Vent Restriction Final Cabinet Positioning If appropriate, attach the 4/6 Vent Adaptor CollarConnect the Gas Supply Gas Supply RequirementsGas Pressure High Altitude Adjustment Derating ProcedureHigh Altitude Orifice Chart Excessive gas pressureFuel Conversion Procedure Conversion Kit ContentsFuel Conversion Tools requiredChange the Pilot Orifice Burner OrificeAdjust the Air Shutter See fig Change the Regulator See figApply the Conversion Labels Wall Thermostat Installation Remote ControlBrick Panel Assembly Glass Frame latch locationsLogset Assembly Install Right Log, Rear Log and Left Log in that orderSurround Assembly Door InstallationDoor Alignment Adjustment Optional Double DoorFlame Appearance / Air Shutter Adjustment System CheckAir Shutter Adjustment Air Inlet SettingsOperation Burner ControlsMaintenance General CleaningGlass Care Gasket InspectionWAS Fireplace CON GZ550 Acadia Lllustrated Parts BreakdownGZ 550 DV Acadia Parts GZ 550 DV Optional Accessories QuickFace Fronts w/ ScreenLighting Instructions Control ValveJøtul ASA Jøtul North America

GZ 550 DV II specifications

The Jotul GZ 550 DV II is a remarkable gas fireplace that combines elegance with efficiency, making it a perfect addition to any modern home. Known for its impressive design and advanced technology, this model captures the essence of warmth and sophistication that homeowners seek in their heating solutions.

One of the main features of the Jotul GZ 550 DV II is its contemporary and sleek aesthetic. Available in various finishes, including a rich black or a striking steel, it complements diverse interior styles, from minimalist to rustic. The full-view glass door enhances the visual appeal, allowing the mesmerizing flames to be a focal point of any room.

The fireplace operates on direct vent gas technology, a standout feature that enables it to draw air from the outside instead of depleting indoor air. This not only enhances safety but also improves energy efficiency, making it a more environmentally friendly choice. Homeowners can enjoy consistent heating without worrying about negatively impacting their indoor air quality.

Equipped with variable flame control, the Jotul GZ 550 DV II allows users to adjust the intensity of the flames according to their preferences. Whether it’s a cozy gathering with friends or a quiet evening alone, the adjustable flames provide a tailored ambiance. Additionally, the remote control feature offers convenience, allowing users to ignite or adjust the fireplace from the comfort of their seat.

Another notable characteristic of this gas fireplace is its efficient heat exchanger system. It maximizes heat output while minimizing gas consumption, ensuring homeowners can enjoy warmth without excessive utility bills. The fireplace has an impressive heating capacity, capable of warming medium to large spaces effectively.

Safety features are paramount in the Jotul GZ 550 DV II. It includes a safety screen to prevent any accidental contact with the hot glass, as well as an automatic shut-off mechanism in case of any irregularities, providing peace of mind for families.

In summary, the Jotul GZ 550 DV II is not just a fireplace; it is a blend of modern design, technology, and efficiency. With its elegant aesthetics, direct vent technology, user-friendly controls, and robust safety features, it stands out as a premier option for those looking to enhance their living space with the warmth and beauty of a gas fireplace. It reflects Jotul's commitment to quality and innovation, making it a worthy investment for any home.