Jotul GZ 550 DV II manual Vent Requirements, Venting Guidelines

Page 9

Vent Requirements

The GZ550 DV Acadia Gas Fireplace is approved for use with direct vent components produced by the following manufacturers:

Simpson Dura-Vent Corporation, 5/8 and 4/6 pipe

Security Vent Ltd. International, 5/8 and 4/6 pipe

Amerivent Corporation, 4/6 pipe

Selkirk Metalbestos Corp. MDV Direct Vent Systems

Use vent components from a single vent manu- facturer. Do not combine parts from different manufacturers in a single installation.

The vent termination must fall within the shaded area designated in the diagrams in Figures 12 - 14.

Venting Guidelines

„The minimum height for a vertical termination cap must be no less than 7' from the top of the unit. The maximum height must not exceed 35'.

„The minimum vent height above the roof or adjacent walls is specified by major building codes. Use the Gas Vent Rule as a general guide. See fig.10. requirements of the approval listing and the manufacturer’s instructions.

„Clearance (airspace) between Vent and Combustibles:

Top - 2” (51 mm) Sides/Bottom - 1” (25 mm)

„Wall Cutout Dimensions:

4/6 Pipe - 10” x 10”

5/8 Pipe - 11” x 11”

„Any horizontal run must rise 1/4” per foot.

„Install venting in accordance with the vent manufacturers’ instructions. Never modify any venting component, or use any damaged venting product.

„THE GAS APPLIANCE AND VENT SYSTEM MUST BE VENTED DIRECTLY TO THE OUTSIDE OF THE BUILDING. DO NOT CONNECT VENT TO A

CHIMNEY SERVING A SOLID FUEL OR ANOTHER GAS APPLIANCE.

 

 

 

Horizontal Overhang

all

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18”.

 

 

 

 

18”.

W

 

 

 

 

Vertical

min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lowest Discharge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opening

Termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

8” m

in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 10. Gas Vent Height Rule: Vertical vent termination height above roof.

„Do not recess the vent terminal into a wall or siding.

„Inspect the vent system annually for blockage and deterioration. If the vent-air intake system is disassembled for any reason, reinstall according to the instructions provided for initial installation.

„Installation of any components not manufactured or approved by Jøtul or failure to meet all clear- ance requirements will void all warranties and may result in property damage, bodily injury, or loss of life.

IN DESIGNING THE VENT SYSTEM, DO NOT

COUNT THE 45° ELBOW CONNECTED TO THE

VENT COLLAR AS AN ELBOW.

45° Elbow

6” Vent Section

„Joint Sealing Requirement: Apply a 1/8” bead of high- temperature (750°F) sealant to the male section of the inner vent pipe. See fig. 9. The cement should seal the inner pipe from the outer pipe.

SEAL ANT

Wall Support

Wall Termination

Figure 9. Seal each inner joint before joining pipe.

Figure 11. Typical minimum horizontal vent configuration - 5/8 Simpson DuraVent. Do not use 4/6 pipe in this configuration.

9

Image 9
Contents Jøtul GZ 550 DV Acadia Direct Vent Gas Fireplace Installation and Operation InstructionsWelcome to Jøtul Table of Contents Specifications Test StandardsInput Rates General Information Suggested Tools for Installation and ServiceInstallation Requirements Safety InformationPlacement and Framing Parallel InstallationCabinet Dimensions Hearth Protection Facing and Clearance RequirementsMantel and Trim Clearance Venting Guidelines Vent RequirementsHorizontal Termination Vertical TerminationHeightin Feet Horizontal Termination ClearanceFireplace Installation Optional BlowerVariable Vent Restriction If appropriate, attach the 4/6 Vent Adaptor Collar Final Cabinet PositioningConnect the Gas Supply Gas Supply RequirementsGas Pressure Derating Procedure High Altitude AdjustmentHigh Altitude Orifice Chart Excessive gas pressureConversion Kit Contents Fuel Conversion ProcedureFuel Conversion Tools requiredBurner Orifice Change the Pilot OrificeAdjust the Air Shutter See fig Change the Regulator See figApply the Conversion Labels Remote Control Wall Thermostat InstallationGlass Frame latch locations Brick Panel AssemblyInstall Right Log, Rear Log and Left Log in that order Logset AssemblyDoor Installation Surround AssemblyDoor Alignment Adjustment Optional Double DoorSystem Check Flame Appearance / Air Shutter AdjustmentAir Inlet Settings Air Shutter AdjustmentBurner Controls OperationGeneral Cleaning MaintenanceGlass Care Gasket InspectionWAS Fireplace CON Lllustrated Parts Breakdown GZ550 AcadiaGZ 550 DV Acadia Parts QuickFace Fronts w/ Screen GZ 550 DV Optional AccessoriesControl Valve Lighting InstructionsJøtul North America Jøtul ASA

GZ 550 DV II specifications

The Jotul GZ 550 DV II is a remarkable gas fireplace that combines elegance with efficiency, making it a perfect addition to any modern home. Known for its impressive design and advanced technology, this model captures the essence of warmth and sophistication that homeowners seek in their heating solutions.

One of the main features of the Jotul GZ 550 DV II is its contemporary and sleek aesthetic. Available in various finishes, including a rich black or a striking steel, it complements diverse interior styles, from minimalist to rustic. The full-view glass door enhances the visual appeal, allowing the mesmerizing flames to be a focal point of any room.

The fireplace operates on direct vent gas technology, a standout feature that enables it to draw air from the outside instead of depleting indoor air. This not only enhances safety but also improves energy efficiency, making it a more environmentally friendly choice. Homeowners can enjoy consistent heating without worrying about negatively impacting their indoor air quality.

Equipped with variable flame control, the Jotul GZ 550 DV II allows users to adjust the intensity of the flames according to their preferences. Whether it’s a cozy gathering with friends or a quiet evening alone, the adjustable flames provide a tailored ambiance. Additionally, the remote control feature offers convenience, allowing users to ignite or adjust the fireplace from the comfort of their seat.

Another notable characteristic of this gas fireplace is its efficient heat exchanger system. It maximizes heat output while minimizing gas consumption, ensuring homeowners can enjoy warmth without excessive utility bills. The fireplace has an impressive heating capacity, capable of warming medium to large spaces effectively.

Safety features are paramount in the Jotul GZ 550 DV II. It includes a safety screen to prevent any accidental contact with the hot glass, as well as an automatic shut-off mechanism in case of any irregularities, providing peace of mind for families.

In summary, the Jotul GZ 550 DV II is not just a fireplace; it is a blend of modern design, technology, and efficiency. With its elegant aesthetics, direct vent technology, user-friendly controls, and robust safety features, it stands out as a premier option for those looking to enhance their living space with the warmth and beauty of a gas fireplace. It reflects Jotul's commitment to quality and innovation, making it a worthy investment for any home.