IMPORTANT:

SAVE THESE INSTRUCTIONS.

THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.

DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THIS APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION WILL VOID THE WARRANTY, CERTIFICATION AND LISTING OF THIS APPLIANCE.

1.The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.

2.This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulat- ing air passageways of the appliance be kept clean.

`S’assurer que le bruleur et le compartiment des commandes sont propres. Voir les instructions d’installation et d’utilisation qui accompagnent l’appareil.

3.The installation must conform to local codes. Your local Jøtul authorized dealer can assist you in determining what is required in your area for a safe and legal installation. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector or authority having jurisdiction to determine what regulations apply in your area.

In the absence of local codes, the installation requirements must comply with the current National codes. In the U.S., these requirements are established in the National Fuel Code, ANSI Z223.1.(NFPA 54). In Canada, the codes have been established in CAN/CGA B149 Fuel Installation Code.

Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation CAN/CGA-B149.

4.DO NOT OPERATE THIS FIREPLACE IF ANY PART HAS BEEN UNDER WATER.

Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Ne pas se servir de cet appareil s’il a ete’ plonge dans l’eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du syste’me de controle et toute commande qui ont ete plonges dans l’eau.

5.Do not operate the fireplace with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Only remove glass for routine service. Always handle glass carefully.

Pour utilisation avec les portes en verre cerifiers aved l’appareil seulemend ou. Ne pas utiliser avec des portes on verre.

6.Notify your insurance company before proceding with installation of this fireplace.

7.This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

Cet appareil peut être installé dans un maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent. Cet appareil doit être utilisé uniquement avec les types de gas indiqués sur la plaque signalétique. Ne pas l’utiliser avec d’autres gas sauf si un kitde conver- sion certifié est installé.

Suggested Tools for

Installation and Service

External regulator (for Propane only)

Piping which complies with local code

Manual shutoff valve - T-Handle in MA

Sediment trap - if required by code

10mm open end wrench

1/2”, 7/16” open end wrench

Phillips head screwdriver

Flat head screwdriver

•Tee joint

Pipe wrench

•Pipe sealant

1/4” nut driver

•Torx T20 screwdriver

Gloves

•Safety glasses

Leak test solution

•Power Drill

Reciprocating Saw

 

5

Image 5
Contents Jøtul GZ 550 DV Acadia Direct Vent Gas Fireplace Installation and Operation InstructionsWelcome to Jøtul Table of Contents Input Rates SpecificationsTest Standards General Information Suggested Tools for Installation and ServiceInstallation Requirements Safety InformationPlacement and Framing Parallel InstallationCabinet Dimensions Mantel and Trim Clearance Hearth ProtectionFacing and Clearance Requirements Venting Guidelines Vent RequirementsHorizontal Termination Vertical TerminationHeightin Feet Horizontal Termination ClearanceVariable Vent Restriction Fireplace InstallationOptional Blower If appropriate, attach the 4/6 Vent Adaptor Collar Final Cabinet PositioningGas Pressure Connect the Gas SupplyGas Supply Requirements Derating Procedure High Altitude AdjustmentHigh Altitude Orifice Chart Excessive gas pressureConversion Kit Contents Fuel Conversion ProcedureFuel Conversion Tools requiredBurner Orifice Change the Pilot OrificeApply the Conversion Labels Adjust the Air Shutter See figChange the Regulator See fig Remote Control Wall Thermostat InstallationGlass Frame latch locations Brick Panel AssemblyInstall Right Log, Rear Log and Left Log in that order Logset AssemblyDoor Installation Surround AssemblyDoor Alignment Adjustment Optional Double DoorSystem Check Flame Appearance / Air Shutter AdjustmentAir Inlet Settings Air Shutter AdjustmentBurner Controls OperationGeneral Cleaning MaintenanceGlass Care Gasket InspectionWAS Fireplace CON Lllustrated Parts Breakdown GZ550 AcadiaGZ 550 DV Acadia Parts QuickFace Fronts w/ Screen GZ 550 DV Optional AccessoriesControl Valve Lighting InstructionsJøtul North America Jøtul ASA

GZ 550 DV II specifications

The Jotul GZ 550 DV II is a remarkable gas fireplace that combines elegance with efficiency, making it a perfect addition to any modern home. Known for its impressive design and advanced technology, this model captures the essence of warmth and sophistication that homeowners seek in their heating solutions.

One of the main features of the Jotul GZ 550 DV II is its contemporary and sleek aesthetic. Available in various finishes, including a rich black or a striking steel, it complements diverse interior styles, from minimalist to rustic. The full-view glass door enhances the visual appeal, allowing the mesmerizing flames to be a focal point of any room.

The fireplace operates on direct vent gas technology, a standout feature that enables it to draw air from the outside instead of depleting indoor air. This not only enhances safety but also improves energy efficiency, making it a more environmentally friendly choice. Homeowners can enjoy consistent heating without worrying about negatively impacting their indoor air quality.

Equipped with variable flame control, the Jotul GZ 550 DV II allows users to adjust the intensity of the flames according to their preferences. Whether it’s a cozy gathering with friends or a quiet evening alone, the adjustable flames provide a tailored ambiance. Additionally, the remote control feature offers convenience, allowing users to ignite or adjust the fireplace from the comfort of their seat.

Another notable characteristic of this gas fireplace is its efficient heat exchanger system. It maximizes heat output while minimizing gas consumption, ensuring homeowners can enjoy warmth without excessive utility bills. The fireplace has an impressive heating capacity, capable of warming medium to large spaces effectively.

Safety features are paramount in the Jotul GZ 550 DV II. It includes a safety screen to prevent any accidental contact with the hot glass, as well as an automatic shut-off mechanism in case of any irregularities, providing peace of mind for families.

In summary, the Jotul GZ 550 DV II is not just a fireplace; it is a blend of modern design, technology, and efficiency. With its elegant aesthetics, direct vent technology, user-friendly controls, and robust safety features, it stands out as a premier option for those looking to enhance their living space with the warmth and beauty of a gas fireplace. It reflects Jotul's commitment to quality and innovation, making it a worthy investment for any home.