Fuel Conversion

The GZ550 DV Acadia Fireplace is designed to for use with either Natural gas or Propane. It is shipped from the factory configured to use Natural gas. A conversion kit is included for conversion to Propane use if desired. Check the identification label on the Control Valve to confirm that the correct fuel is used.

WARNING:

THE CONVERSION KIT IS TO BE IN- STALLED BY AN AUTHORIZED JØTUL SERVICE TECHNICIAN IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUC- TION AND ALL CODES AND REQUIRE- MENTS OF THE AUTHORITY HAVING JU- RISDICTION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERI- OUS INJURY OR PROPERTY DAMAGE. THE QUALIFIED AGENCY PERFORMING THIS WORK ASSUMES RESPONSIBILITY FOR THIS CONVERSION.

IN CANADA:

THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIRE- MENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCOR- DANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE.

Cet equipement de conversion sera installe par une agence qualifiee de service conformement aux instructions du fabricant et toutes exigences et codes applicables de l’autorises avoir la juridiction. Si l’information dans cette Instruction n’est pas suivie exactement, un fey, explosion ou production de protoxyde de carbone peut resulter blessure personnelle de vie. L’agence qualifiee de service est esponsable de l’installation n’est pas propre et complete jusqu’a l’operation de l’appareil converti est cheque suivant les criteres etablis dans les instructions de proprietaire provisionnees avec l’equipement.

Tools required:

1/4” Nut driver, 7/16” and 1/2” open end wrench or deep well socket, 4 mm allen wrench, Torx t20 or slotted screwdriver.

Conversion Kit Contents:

1 Regulator Tower labeled for Propane

3 Regulator Tower Screws

• 1 Burner Orifice (#38 NG, 1.55 mm LP)

1 Pilot Orifice ( #30 for LP, #51 for NG)

Label A - to be completed and applied to the back of the fireplace.

Label B - apply to the fireplace Rating Plate as designated on the plate.

WARNING: If appropriate, be sure to unplug the blower before proceeding with this conversion.

Fuel Conversion Procedure

1. Remove the Glass Frame:

Follow the removal procedure detailed on page 1.

2. Empty the firebox:

Lift and remove the Fettle and Logset package. CAUTION: THE LOGS ARE FRAGILE. Handle them with care and set aside out of the way.

Remove the Burner Skirt. Lift and tilt it to clear the firebox opening. See fig. 28.

3. Change the Burner Orifice:

Loosen the locknut on the Air Shutter Stem, located under the firebox floor to the right of the Control Valve. Pull the stem forward as far as it will go. This will allow you to disengage the Burner Assembly. See fig. 29.

Lift the rear of the Burner Tube and rotate slightly forward. Slide the tube back enough to disengage it from the Air Shutter and Burner Orifice, then lift out. See fig. 30.

Slide the Air Shutter back out of the way to expose the orifice. See fig. 31. Using a ½” open end wrench or deep well socket remove the burner orifice and replace with the appropriate orifice, supplied in the kit.

16

Image 16
Contents Installation and Operation Instructions Jøtul GZ 550 DV Acadia Direct Vent Gas FireplaceWelcome to Jøtul Table of Contents Test Standards SpecificationsInput Rates Suggested Tools for Installation and Service General InformationSafety Information Installation RequirementsPlacement and Framing Parallel InstallationCabinet Dimensions Facing and Clearance Requirements Hearth ProtectionMantel and Trim Clearance Vent Requirements Venting GuidelinesVertical Termination Horizontal TerminationHorizontal Termination Clearance Heightin FeetOptional Blower Fireplace InstallationVariable Vent Restriction Final Cabinet Positioning If appropriate, attach the 4/6 Vent Adaptor CollarGas Supply Requirements Connect the Gas SupplyGas Pressure High Altitude Adjustment Derating ProcedureHigh Altitude Orifice Chart Excessive gas pressureFuel Conversion Procedure Conversion Kit ContentsFuel Conversion Tools requiredChange the Pilot Orifice Burner OrificeChange the Regulator See fig Adjust the Air Shutter See figApply the Conversion Labels Wall Thermostat Installation Remote ControlBrick Panel Assembly Glass Frame latch locationsLogset Assembly Install Right Log, Rear Log and Left Log in that orderSurround Assembly Door InstallationDoor Alignment Adjustment Optional Double DoorFlame Appearance / Air Shutter Adjustment System CheckAir Shutter Adjustment Air Inlet SettingsOperation Burner ControlsMaintenance General CleaningGlass Care Gasket InspectionWAS Fireplace CON GZ550 Acadia Lllustrated Parts BreakdownGZ 550 DV Acadia Parts GZ 550 DV Optional Accessories QuickFace Fronts w/ ScreenLighting Instructions Control ValveJøtul ASA Jøtul North America

GZ 550 DV II specifications

The Jotul GZ 550 DV II is a remarkable gas fireplace that combines elegance with efficiency, making it a perfect addition to any modern home. Known for its impressive design and advanced technology, this model captures the essence of warmth and sophistication that homeowners seek in their heating solutions.

One of the main features of the Jotul GZ 550 DV II is its contemporary and sleek aesthetic. Available in various finishes, including a rich black or a striking steel, it complements diverse interior styles, from minimalist to rustic. The full-view glass door enhances the visual appeal, allowing the mesmerizing flames to be a focal point of any room.

The fireplace operates on direct vent gas technology, a standout feature that enables it to draw air from the outside instead of depleting indoor air. This not only enhances safety but also improves energy efficiency, making it a more environmentally friendly choice. Homeowners can enjoy consistent heating without worrying about negatively impacting their indoor air quality.

Equipped with variable flame control, the Jotul GZ 550 DV II allows users to adjust the intensity of the flames according to their preferences. Whether it’s a cozy gathering with friends or a quiet evening alone, the adjustable flames provide a tailored ambiance. Additionally, the remote control feature offers convenience, allowing users to ignite or adjust the fireplace from the comfort of their seat.

Another notable characteristic of this gas fireplace is its efficient heat exchanger system. It maximizes heat output while minimizing gas consumption, ensuring homeowners can enjoy warmth without excessive utility bills. The fireplace has an impressive heating capacity, capable of warming medium to large spaces effectively.

Safety features are paramount in the Jotul GZ 550 DV II. It includes a safety screen to prevent any accidental contact with the hot glass, as well as an automatic shut-off mechanism in case of any irregularities, providing peace of mind for families.

In summary, the Jotul GZ 550 DV II is not just a fireplace; it is a blend of modern design, technology, and efficiency. With its elegant aesthetics, direct vent technology, user-friendly controls, and robust safety features, it stands out as a premier option for those looking to enhance their living space with the warmth and beauty of a gas fireplace. It reflects Jotul's commitment to quality and innovation, making it a worthy investment for any home.