Fujitsu AOU9RLS Operating Tips, Operation and Performance, Auto Restart, Heating Performance

Page 17

TROUBLESHOOTING

 

Symptom

Items to check

See Page

 

 

 

 

CHECK ONCE

Doesn’t operate at all:

● Is the Power Supply Plug disconnected its outlet?

 

MORE

 

● Has there been a power failure?

 

 

● Has a fuse blown out, or a circuit breaker been tripped?

 

 

 

 

 

 

 

● Is the timer operating?

8 - 9

 

 

 

 

 

 

● Is the Air Filter dirty?

 

 

 

● Air the air conditioner’s intake grille or outlet port blocked?

 

 

Poor Cooling performance:

● Did you adjust the room temperature settings (thermostat) cor-

 

 

 

rectly?

 

 

 

● Is there a window or door open?

 

 

● In the case of Cooling operation, is a window allowing bright sun-

 

 

 

light to enter? (Close the curtains.)

 

 

 

● In the case of Cooling operation, are there heating apparatus and

 

 

 

computers inside the room, or are there too many people in the

 

 

 

room?

 

 

 

 

 

 

 

● Is the unit set for SUPER QUIET operation?

6

 

 

 

 

 

The unit operates

● Are the Remote Control Unit’s batteries dead?

 

 

differently from the Remote

● Are the Remote Control Unit’s batteries loaded properly?

5

 

Control Unit’s setting:

 

 

 

 

 

 

If the problem persists after performing these checks, or if you notice burning smells, or both the ORERATION Indicator Lamp (Fig. 3 a4) and the TIMER Indicator Lamp (Fig. 3 a5) flashes, or only the TIMER Indicator Lamp (Fig. 3 a5) flashes, immediately stop operation, disconnect the Power Supply, and consult authorized service personnel.

OPERATING TIPS

Operation and Performance

Heating Performance

Microcomputer-controlled Automatic Defrosting

This air conditioner operates on the heat-pump princi- ple, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insufficient heating performance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating appliance.

Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air con- ditioner until the room is heated.

When using the Heating mode under conditions of low outdoor temperature and high humidity, frost may form on the outdoor unit, resulting in reduced operating per- formance.

In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Auto- matic Defrosting function. If frost forms, the air condi- tioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7-15 minutes).

During Automatic Defrosting operation, the DEFROST In- dicator Lamp (yellow) will light.

AUTO Restart

In Event of Power Interruption

The air conditioner power has been interrupted by a power failure. The air conditioner will then restart auto- matically in its previous mode when the power is restored.

Operated by setting before the power failure.

If a power failure occurs during TIMER operation, the timer will be reset and the unit will begin (or stop) operation at the new time setting. In the event that this kind of timer fault occurs the TIMER Indicator Lamp will flash (see Page. 4).

Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily disconnect the Power Supply Plug, reconnect it, and then use the Remote Control Unit to resume operation.

En-16

Image 17
Contents Mode D’EMPLOI Safety Precautions ContentsSleep Timer Timer MIN. Heat Coil DRY Features and FunctionsEconomy Maintenance En-3 Name of Parts Preparation Operation About Auto Changeover Operation About Mode OperationTo Stop Operation Press the START/STOP button b8 OFF timer or on timer operation Timer OperationTo Use the Program timer Press the START/STOP button b8 Set the desired times for OFF timer and on timerAbout the Sleep Timer Sleep Timer OperationDuring Heating operation During Cooling/Dry operationTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationCoil DRY Operation Swing OperationTo select Swing Operation Press the Swing button b11 About Swing OperationMinimum Heat Operation Timer Sleep FAN Speed SwingManual Auto Operation About the Minimum Heat OperationCleaning and Care Install the two Air filters and close the Open Panel Replace them by two new Air cleaning filtersReplacing dirty Air cleaning filters Open the Open Panel and remove the Air fil- tersSymptom Problem TroubleshootingNormal FunctionOperating Tips Event of Power InterruptionOperation and Performance Auto RestartTemperature and Humidity Range Specification

AOU12RLS, Heat & Cool Model (Reverse Cycle), ASU12RLS, AOU9RLS, ASU9RLS specifications

The Fujitsu ASU9RLS, AOU12RLS, ASU12RLS, and AOU9RLS models represent the pinnacle of advanced climate control solutions, combining energy efficiency with exceptional performance in both heating and cooling applications. These reverse cycle air conditioning systems are designed to cater to a wide range of residential and light commercial environments, ensuring comfort throughout the year.

One of the standout features of these models is the inverter technology that optimizes energy consumption. By continuously adjusting the compressor speed to maintain the desired temperature, these units minimize fluctuations, thereby enhancing comfort and reducing energy bills. This technology also leads to quieter operation, making it an excellent choice for homes and offices where noise level is a concern.

The ASU series offers a sleek and modern design, allowing it to blend seamlessly into various interior decors. User-friendly remote controls and smart sensors enable easy management and monitoring of temperature settings, ensuring users can maintain their ideal comfort levels with minimal effort. Additionally, the models are equipped with a range of air filtration systems, including washable filters that effectively capture dust and allergens, contributing to healthier indoor air quality.

Fujitsu's commitment to energy efficiency is further reflected in the high star ratings for these models, which comply with the latest environmental standards. The reverse cycle capability not only provides effective cooling during the hotter months but also ensures efficient heating when temperatures drop, making these models versatile and cost-effective.

Durability is another hallmark of Fujitsu's design philosophy. The units are built with high-quality materials, ensuring longevity and resistance to various environmental conditions. Advanced technology is also used to ensure that the outdoor units can operate effectively even in extreme weather conditions, providing reliable performance year-round.

In summary, the Fujitsu ASU9RLS, AOU12RLS, ASU12RLS, and AOU9RLS models offer an ideal combination of energy efficiency, exceptional performance, and advanced technology. Their inverter systems, stylish design, effective filtration, and durability make them an excellent choice for anyone looking to enhance their indoor climate control while maintaining energy efficiency. Whether for a cozy home or a productive office space, these reverse cycle units are engineered to deliver comfort and reliability in any season.