Fujitsu ASU9RLS, ASU12RLS Sleep Timer Operation, About the Sleep Timer, During Heating operation

Page 10

SLEEP TIMER OPERATION

Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.

To Use the SLEEP Timer

While the air conditioner is operating or stopped, press the SLEEP button (Fig. 6 b5).

The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 a4) lights and the TIMER Indicator Lamp (orange) (Fig. 3 a5) light.

To Change the Timer Settings

Press the SLEEP button (Fig. 6 b5) once again and set the time using the TIMER SET ( / ) buttons (Fig. 6 b13).

Set the time while the Timer Mode Display is flashing (the flashing will continue about five seconds).

button: Press to advance the time. button: Press to reverse the time.

About five seconds later, the entire display will reappear.

To Cancel the Timer:

Use the TIMER MODE button to select “CANCEL”.

The air conditioner will return to normal operation.

To Stop the Air Conditioner During Timer Operation:

Press the START/STOP button.

About the SLEEP Timer

To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting. When the set time has elapsed, the air conditioner completely stops.

During Heating operation:

When the SLEEP timer is set, the thermostat setting is automatically lowered 2 °F every thirty minutes. When the thermostat has been lowered a total of 8 °F, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.

During Cooling/Dry operation:

When the SLEEP timer is set, the thermostat setting is auto- matically raised 2 °F every sixty minutes. When the thermo- stat has been raised a total of 4 °F, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.

SLEEP timer setting

 

 

 

SLEEP timer setting

 

 

 

 

2 °F

4 °F

6 °F

8 °F

 

 

Set time

 

 

 

 

 

30

 

 

minutes

1 hour

 

 

 

1 hour

 

 

1 hour

2 °F

4 °F

 

30 minutes

 

 

Set time

 

 

En-9

Image 10
Contents Mode D’EMPLOI Contents Safety PrecautionsEconomy Maintenance Features and FunctionsSleep Timer Timer MIN. Heat Coil DRY En-3 Name of Parts Preparation Operation To Stop Operation Press the START/STOP button b8 About Mode OperationAbout Auto Changeover Operation To Use the Program timer Press the START/STOP button b8 Timer OperationOFF timer or on timer operation Set the desired times for OFF timer and on timerDuring Heating operation Sleep Timer OperationAbout the Sleep Timer During Cooling/Dry operationAdjusting the Direction of AIR Circulation Types of Air flow Direction SettingTo select Swing Operation Press the Swing button b11 Swing OperationCoil DRY Operation About Swing OperationManual Auto Operation Timer Sleep FAN Speed SwingMinimum Heat Operation About the Minimum Heat OperationCleaning and Care Replacing dirty Air cleaning filters Replace them by two new Air cleaning filtersInstall the two Air filters and close the Open Panel Open the Open Panel and remove the Air fil- tersNormal TroubleshootingSymptom Problem FunctionOperation and Performance Event of Power InterruptionOperating Tips Auto RestartSpecification Temperature and Humidity Range

AOU12RLS, Heat & Cool Model (Reverse Cycle), ASU12RLS, AOU9RLS, ASU9RLS specifications

The Fujitsu ASU9RLS, AOU12RLS, ASU12RLS, and AOU9RLS models represent the pinnacle of advanced climate control solutions, combining energy efficiency with exceptional performance in both heating and cooling applications. These reverse cycle air conditioning systems are designed to cater to a wide range of residential and light commercial environments, ensuring comfort throughout the year.

One of the standout features of these models is the inverter technology that optimizes energy consumption. By continuously adjusting the compressor speed to maintain the desired temperature, these units minimize fluctuations, thereby enhancing comfort and reducing energy bills. This technology also leads to quieter operation, making it an excellent choice for homes and offices where noise level is a concern.

The ASU series offers a sleek and modern design, allowing it to blend seamlessly into various interior decors. User-friendly remote controls and smart sensors enable easy management and monitoring of temperature settings, ensuring users can maintain their ideal comfort levels with minimal effort. Additionally, the models are equipped with a range of air filtration systems, including washable filters that effectively capture dust and allergens, contributing to healthier indoor air quality.

Fujitsu's commitment to energy efficiency is further reflected in the high star ratings for these models, which comply with the latest environmental standards. The reverse cycle capability not only provides effective cooling during the hotter months but also ensures efficient heating when temperatures drop, making these models versatile and cost-effective.

Durability is another hallmark of Fujitsu's design philosophy. The units are built with high-quality materials, ensuring longevity and resistance to various environmental conditions. Advanced technology is also used to ensure that the outdoor units can operate effectively even in extreme weather conditions, providing reliable performance year-round.

In summary, the Fujitsu ASU9RLS, AOU12RLS, ASU12RLS, and AOU9RLS models offer an ideal combination of energy efficiency, exceptional performance, and advanced technology. Their inverter systems, stylish design, effective filtration, and durability make them an excellent choice for anyone looking to enhance their indoor climate control while maintaining energy efficiency. Whether for a cozy home or a productive office space, these reverse cycle units are engineered to deliver comfort and reliability in any season.