Fujitsu ASU18RL, AOU18RL operation manual Timer Operation

Page 10

TIMER OPERATION

Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (P. 4).

To Use the ON timer or OFF timer

1

Press the START/STOP button (Fig. 6 R)

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light.

2

Press the TIMER MODE button (Fig. 6 O) to select the

OFF timer or ON timer operation.

 

Each time the button is pressed the timer function changes in the follow-

 

ing order:

 

 

 

 

 

 

sCANCEL

 

sOFF

sON

 

 

 

 

 

 

 

 

 

 

 

PROGRAM(OFF ON, OFF ON) t

 

 

 

 

 

 

The indoor unit’s green TIMER Indicator Lamp (Fig. 3 6) will light.

3

Use the TIMER SET buttons (Fig. 6 P) to adjust the

desired OFF time or ON time.

Set the time while the time display is flashing (the flashing will continue for about five seconds).

button: Press to advance the time. button: Press to reverse the time.

To Cancel the Timer

Use the TIMER button to select “CANCEL”. The air conditioner will return to normal operation.

To Change the Timer Settings

Perform steps 2 and 3.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.

About five seconds later, the entire display will reappear.

To Use the Program timer

1

Press the START/STOP button (Fig. 6 R).

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light.

2

Set the desired times for OFF timer and ON timer.

See the section “To Use the ON timer or OFF timer” to set the desired

 

mode and times.

 

About three seconds later, the entire display will reappear.

 

The indoor unit’s TIMER Indicator Lamp (green) (Fig. 3 6) will light.

3

Press the TIMER MODE button (Fig. 6 O) to select the

PROGRAM timer operation (OFF

 

ON or OFF

 

ON

 

 

 

will display).

 

The display will alternately show “OFF timer” and “ON timer”, then change

 

to show the time setting for the operation to occur first.

 

The program timer will begin operation. (If the ON timer has been se-

 

lected to operate first, the unit will stop operating at this point.)

 

About five seconds later, the entire display will reappear.

About the Program timer

The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

The first timer function to operate will be the one set nearest to the current time.

The order of operation is indicated by the arrow in the Remote Control Unit’s Display (OFF ON, or OFF ON).

One example of Program timer use might be to have the air conditioner auto- matically stop (OFF timer) after you go to sleep, then start (ON timer) automati- cally in the morning before you arise.

En-7

To Cancel the Timer

Use the TIMER MODE button to select “CANCEL”.

The air conditioner will return to normal operation.

To Change the Timer Settings

1.Follow the instructions given in the section “To Use the ON Timer or OFF Timer” to se- lect the timer setting you wish to change.

2.Press the TIMER MODE button to select either OFF ON or OFF ON.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reap- pears, then press the appropriate buttons to change the operating condition desired.

05L256_9315255013-01_En

7

2005.12.9, 11:49 AM

Image 10
Contents Operating Manual Español Français EnglishContents Safety PrecautionsOperation Timer Super Quiet Coil DRY Fiche Technique SpecificationsEspecificaciones Features and Functions InverterName of Parts Indoor Unit Operating Control Panel Fig Manual Auto buttonPreparation Operation To Stop Operation Press the START/STOP button R About Mode OperationAbout Auto Changeover Operation Timer Operation During Heating operation Sleep Timer OperationAbout the Sleep Timer During Cooling/Dry operationRight-Left Adjustment Adjust the Right-Left louvers Adjusting the Direction of AIR CirculationVertical Air Direction Adjustment Press the SET button S Types of Air flow Direction SettingManual Auto Operation Swing OperationCoil DRY Operation To select Swing Operation Press the Swing button TCleaning and Care Replacing dirty Air cleaning filters Install the Air cleaning filter set setInstall the two Air filters and close the Intake Grille Replace them by two new Air cleaning filtersTroubleshooting Symptom ProblemOperation and Performance Event of Power InterruptionOperating Tips Auto RestartIndoor temperature Temperature and Humidity RangeCooling Mode Dry Mode Heating Mode Outdoor temperature Tips for saving energy05L2569315255013-01En 2005.12.9, 1149 AM