Fujitsu AOU18RL Install the Air cleaning filter set set, Replacing dirty Air cleaning filters

Page 15

CLEANING AND CARE

Air Cleaning Filter Installation

1.Open the Intake Grille and remove the Air filters.

Air Filter

(Right & Left)

2.Install the Air cleaning filter set (set of 2).

1Set the air cleaning filter into the air cleaning filter frame.

Air cleaning filter set

Air cleaning filter frame

Air cleaning filter

2 Engage the latch at both ends of the filter with the two hooks at the rear of the air cleaning filter frame.

Hook (2 places at the rear)

Latch (2 places)

Take care that the air cleaning filter does not project be- yond the frame.

3 Engage the four fixing locations at the top and bot- tom of the air cleaning filter frame with the hooks of the air filter.

Rear of the filter

Fixing location, hook (4 places)

3.Install the two Air filters and close the Intake Grille.

Air Filter

(Right & Left)

When air cleaning filters are used, the effect will increased by setting the fan speed to “High”.

Replacing dirty Air cleaning filters

Replace filters with the following components (purchased separately).

POLYPHENOL CATECHIN AIR CLEANING FILTER : UTR-FA03-2

Negative air ions deodorizing filter: UTR-FA03-3

1.Open the Intake Grille and remove the Air filters.

Air Filter

(Right & Left)

2.Replace them by two new Air cleaning filters.

1Remove the old air cleaning filters in reverse order of their installation.

2Install in the same way as for installation of the air cleaning filter set.

3.Install the two Air filters and close the Intake Grille.

Air Filter(Right & Left)

In regard to the Air Cleaning Filters

POLYPHENOL CATECHIN AIR CLEANING FILTER (one sheet)

The Air Cleaning Filters are disposable filters. (They can not be washed and reused.)

For storage of the Air Cleaning Filters, use the filters as soon as possible after the package has been opened. (The air cleaning effect decreases when the filters are left in the opened package)

Generally, the filters should be exchanged about every three months.

Please buy delicated air cleaning filters (UTR-FA03-2) (Sold separately) to exchange the used dirty air cleaning filters.

[Negative air ions deodorizing filter (one sheet) — light blue]

The filters should be exchanged about every three years so as to maintain the deodorizing effect.

Filter frame is not a one-off product.

Please buy delicated deodorizing filter (UTR-FA03-3) (Sold separately) when exchanging the filters.

Maintenance of Deodorizing Filters

In order to maintain the deodorizing effect, please clean the filter in the follow way once three months.

1 Remove the deodorizing filter.

2 Clean with water and dry in the air.

1)Flush the filters with high-pressure hot water until the surface of the filters are covered with water. Please flush with diluent neutral detergent.

Never wash by reaming or rubbing, otherwise it will damage the deodorizing effect.

2)Rinse with water flow.

3)Dry in shade.

3 Reinstall the deodorizing filter.

En-12

05L256_9315255013-01_En

12

2005.12.9, 11:49 AM

Image 15
Contents Español Français English Operating ManualSafety Precautions ContentsOperation Timer Super Quiet Coil DRY Specifications Fiche TechniqueEspecificaciones Inverter Features and FunctionsIndoor Unit Operating Control Panel Fig Manual Auto button Name of PartsPreparation Operation About Mode Operation To Stop Operation Press the START/STOP button RAbout Auto Changeover Operation Timer Operation During Cooling/Dry operation Sleep Timer OperationAbout the Sleep Timer During Heating operationTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationVertical Air Direction Adjustment Press the SET button S Right-Left Adjustment Adjust the Right-Left louversTo select Swing Operation Press the Swing button T Swing OperationCoil DRY Operation Manual Auto OperationCleaning and Care Replace them by two new Air cleaning filters Install the Air cleaning filter set setInstall the two Air filters and close the Intake Grille Replacing dirty Air cleaning filtersSymptom Problem TroubleshootingAuto Restart Event of Power InterruptionOperating Tips Operation and PerformanceTips for saving energy Temperature and Humidity RangeCooling Mode Dry Mode Heating Mode Outdoor temperature Indoor temperature05L2569315255013-01En 2005.12.9, 1149 AM