Empire Products BF-30-2, BF-20-2 Lighting Instructions, For Your Safety Read Before Lighting

Page 10

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call your gas supplier from a neigh- bor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set thermostat (gas control knob) to lowest setting.

3.Turn off all electric power to the appliance (if appli- cable).

4.Push in gas control knob slightly and turn clockwise to "OFF". Do not force.

5.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

6. Find pilot - the pilot is attached at the bottom of the burner assembly .

7.Turn gas control knob

counterclockwise to "PILOT."

8.Push in gas control knob all the way and hold in. Repeatedly push the piezo ignitor button until pilot is lit (or use a match to light pilot). Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4 through 8.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

9.Attention! Gas control has an INTERLOCK latching device. When the pilot is initially lit and the safety magnet is energized (pilot stays "ON") the INTER- LOCK latching device becomes operative. If the gas control is turned to the "OFF" position or gas flow to the appliance is shut off, the pilot cannot be relighted until the safety magnet is de-energized (approxi- mately 60 seconds). There will be an audible "click" when the safety magnet in the gas control is de- energized. Pilot can now be relighted. Repeat steps 4 through 8.

10.Turn gas control knob counterclockwise to "HI".

11.Turn on all electric power to appliance (if applicable).

12.Set thermostat (gas control knob) to desired setting from "HI" to "LO".

TO TURN OFF GAS TO APPLIANCE

1.Set thermostat (gas control knob) to lowest setting.

2.Turn off all electric power to appliance if service is to be performed (if applicable).

3.Push in gas control knob slightly and turn clock-

wise to "OFF". Do not force.

Page 10

16012-1-0504

Image 10
Contents Installation Instructions Table of Contents Air, heater may give off Carbon MONOXIDE, an odor Important Safety InformationHeater. In this type of application, a fan to circulate Safety Information for Users of LP-GAS LP-GAS Warning OdorSpecifications IntroductionWater Vapor a BY-PRODUCT of Unvented Room Heaters Unusually Tight ConstructionGAS Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System Gas SupplyOptional Floor Stand Installation ClearancesOn Solid Wall Wall Mount InstallationBF-10 and BF-20 BF-30 On Sheet Rock Wall For Your Safety Read Before Lighting Lighting InstructionsCleaning Main Burner Orifice and Main Burner Main Burner Flame CharacteristicsAir Shutter Adjustment Figure Piezo Pilot Ignitor InstructionsOxygen Depletion Sensor Pilot Figure Pilot Flame CharacteristicsThermostat Operation BF-10Appliance Maintenance Troubleshooting HOW to Order Repair Parts Parts ListPart number and description of part coincide Parts View Optional Blower Installation Instructions Excessive Blower Wheel NoiseOptional Blower Installation Instructions Service Notes Belleville, Illinois

BF-30-2, BF-20-2, BF-10-2 specifications

Empire Products has established itself as a notable player in the realm of industrial solutions with its comprehensive range of BF series products, particularly the BF-30-2, BF-10-2, and BF-20-2. These models, each designed to meet various operational needs, exhibit the company’s commitment to innovation and efficiency.

The BF-30-2 is the flagship model in the series, equipped with advanced features that cater to heavy-duty applications. It boasts a robust design coupled with high-performance capabilities. One of its standout technologies includes an efficient energy management system that optimizes power consumption without compromising performance. This model also features a user-friendly interface for easy operation and monitoring, ensuring that users can quickly adapt to its functionalities. The BF-30-2 is particularly well-suited for applications requiring precision and high throughput, making it a favorite among manufacturers looking for reliability and efficiency.

Next in the lineup is the BF-20-2, which strikes a balance between power and versatility. This model is designed to handle moderate to intense workloads, making it ideal for businesses that require adaptability in their operations. It is equipped with adaptive technology that allows it to adjust its performance based on real-time operational demands. The BF-20-2 also offers enhanced safety features, ensuring that operators can work confidently and comfortably.

The BF-10-2, while smaller in capacity, should not be underestimated. It is engineered for small to medium-sized tasks, perfect for businesses that require compact solutions without sacrificing quality. This model incorporates cutting-edge materials and components designed to maximize durability and reduce maintenance needs. Additionally, the BF-10-2 is highly energy-efficient, making it an excellent choice for environmentally conscious companies looking to minimize their carbon footprint.

All three models share a few key characteristics that highlight the essence of Empire Products' engineering prowess. They are designed for easy integration into existing systems, which simplifies upgrades for businesses looking to enhance their operational capabilities. Moreover, their modular design allows for customizable configurations, catering to specific user requirements.

In conclusion, the Empire Products BF series, encompassing the BF-30-2, BF-20-2, and BF-10-2, represents the synergy of performance, innovation, and versatility. Each model serves a unique purpose, allowing businesses to select the perfect equipment to meet their operational goals while benefiting from the latest technological advancements in the industry.