Empire Products BF-20-2, BF-30-2, BF-10-2 installation instructions Important Safety Information

Page 3

IMPORTANT SAFETY INFORMATION

THIS IS A HEATING APPLIANCE

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.

• An unvented room heater having an input rating of more

Installation and repair should be done by a QUALIFIED

than 6,000 Btu per hour shall not be installed in a

 

SERVICE PERSON. The appliance should be inspected

bathroom.

 

before use and at least annually by a professional service

• An unvented room heater having an input rating of more

 

person. More frequent cleaning may be required due to

than 10,000 Btu per hour shall not be installed in a

 

excessive lint from carpeting, bedding materials, etc. It is

bedroom or bathroom.

 

imperative that control compartments, burners and

• Due to high temperatures, the appliance should be

 

circulating air passageways of the appliance be kept clean.

DO NOT use this room heater if any part has been under

located out of traffic and away from furniture and

draperies.

 

water. Immediately call a qualified service technician to

• Children and adults should be alerted to the hazard of

 

inspect the room heater and to replace any part of the

 

control system and any gas control which has been under

high surface temperature and should stay away to avoid

 

 

water.

burns or clothing ignition.

 

Keep appliance area clear and free from combustible

• Young children should be carefully supervised when they

 

materials, gasoline and other flammable vapors and liquids.

are in the same room with the appliance.

 

WARNING: ANY CHANGE TO THIS HEATER OR ITS

• Do not place clothing or other flammable material on or

 

CONTROLS CAN BE DANGEROUS.

near the appliance.

 

 

 

• Due to high surface temperatures, keep children, clothing

Any safety screen or guard removed for servicing an

and furniture away.

appliance must be replaced prior to operating the heater.

• WARNING: Failure to keep the primary air opening(s) of

• WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with

the burner(s) clean may result in sooting and property

heater.

damage.

WARNING

When used without adequate combustion and ventilation

 

 

CARBON MONOXIDE POISONING MAY LEAD TO

 

air, heater may give off CARBON MONOXIDE, an odor-

 

DEATH.

 

less, poisonous gas.

 

 

 

Early signs of carbon monoxide poisoning resemble the flu,

Do not install heater until all necessary provisions are

 

 

with headache, dizziness and/or nausea. If you have these

made for combustion and ventilation air. Consult the

 

 

signs, heater may not be working properly. Get fresh air at

written instructions provided with the heater for infor-

 

 

once! Have heater serviced.

mation concerning combustion and ventilation air. In

 

 

Some people — pregnant women, persons with heart or lung

the absence of instructions, refer to the National Fuel

 

 

disease, anemia, those under the influence of alcohol , those

Gas Code, ANSI Z223.1, Section 5.3 or applicable local

 

 

at high altitudes — are more affected by carbon monoxide

codes.

 

 

than others.

This heater is equipped with a PILOT LIGHT SAFETY

The pilot light safety system senses the depletion of oxygen

SYSTEM designed to turn off the heater if not enough fresh

at its location. If this heater is installed in a structure having

air is available.

a high vertical dimension, the possibility exists that the

 

 

oxygen supply at the higher levels will be less than that at the

DO NOT TAMPER WITH PILOT LIGHT SAFETY

 

 

heater. In this type of application, a fan to circulate the

SYSTEM!

 

 

structure air will minimize this effect. The use of this fan will

 

 

If heater shuts off, do not relight until you provide fresh air.

also improve the comfort level in the structure. When a fan

If heater keeps shutting off, have it serviced. Keep burner

is used to circulate air, it should be located so that the air flow

is not directed at the burner.

and control compartment clean.

 

 

16012-1-0504

Page 3

Image 3
Contents Installation Instructions Table of Contents Important Safety Information Air, heater may give off Carbon MONOXIDE, an odorHeater. In this type of application, a fan to circulate LP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsUnusually Tight Construction Water Vapor a BY-PRODUCT of Unvented Room HeatersGas Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System GAS SupplyClearances Optional Floor Stand InstallationWall Mount Installation On Solid WallBF-10 and BF-20 BF-30 On Sheet Rock Wall Lighting Instructions For Your Safety Read Before LightingPiezo Pilot Ignitor Instructions Main Burner Flame CharacteristicsAir Shutter Adjustment Figure Cleaning Main Burner Orifice and Main BurnerBF-10 Pilot Flame CharacteristicsThermostat Operation Oxygen Depletion Sensor Pilot FigureAppliance Maintenance Troubleshooting Parts List HOW to Order Repair PartsPart number and description of part coincide Parts View Excessive Blower Wheel Noise Optional Blower Installation InstructionsOptional Blower Installation Instructions Service Notes Belleville, Illinois

BF-30-2, BF-20-2, BF-10-2 specifications

Empire Products has established itself as a notable player in the realm of industrial solutions with its comprehensive range of BF series products, particularly the BF-30-2, BF-10-2, and BF-20-2. These models, each designed to meet various operational needs, exhibit the company’s commitment to innovation and efficiency.

The BF-30-2 is the flagship model in the series, equipped with advanced features that cater to heavy-duty applications. It boasts a robust design coupled with high-performance capabilities. One of its standout technologies includes an efficient energy management system that optimizes power consumption without compromising performance. This model also features a user-friendly interface for easy operation and monitoring, ensuring that users can quickly adapt to its functionalities. The BF-30-2 is particularly well-suited for applications requiring precision and high throughput, making it a favorite among manufacturers looking for reliability and efficiency.

Next in the lineup is the BF-20-2, which strikes a balance between power and versatility. This model is designed to handle moderate to intense workloads, making it ideal for businesses that require adaptability in their operations. It is equipped with adaptive technology that allows it to adjust its performance based on real-time operational demands. The BF-20-2 also offers enhanced safety features, ensuring that operators can work confidently and comfortably.

The BF-10-2, while smaller in capacity, should not be underestimated. It is engineered for small to medium-sized tasks, perfect for businesses that require compact solutions without sacrificing quality. This model incorporates cutting-edge materials and components designed to maximize durability and reduce maintenance needs. Additionally, the BF-10-2 is highly energy-efficient, making it an excellent choice for environmentally conscious companies looking to minimize their carbon footprint.

All three models share a few key characteristics that highlight the essence of Empire Products' engineering prowess. They are designed for easy integration into existing systems, which simplifies upgrades for businesses looking to enhance their operational capabilities. Moreover, their modular design allows for customizable configurations, catering to specific user requirements.

In conclusion, the Empire Products BF series, encompassing the BF-30-2, BF-20-2, and BF-10-2, represents the synergy of performance, innovation, and versatility. Each model serves a unique purpose, allowing businesses to select the perfect equipment to meet their operational goals while benefiting from the latest technological advancements in the industry.