Empire Products BF-30-2, BF-20-2, BF-10-2 installation instructions Parts View

Page 16

PARTS VIEW

Page 16

16012-1-0504

Image 16
Contents Installation Instructions Table of Contents Air, heater may give off Carbon MONOXIDE, an odor Important Safety InformationHeater. In this type of application, a fan to circulate Safety Information for Users of LP-GAS LP-GAS Warning OdorSpecifications IntroductionWater Vapor a BY-PRODUCT of Unvented Room Heaters Unusually Tight ConstructionInstalling a New Main Gas Cock Pressure Testing of the Gas Supply SystemGAS Supply Gas SupplyOptional Floor Stand Installation ClearancesOn Solid Wall Wall Mount InstallationBF-10 and BF-20 BF-30 On Sheet Rock Wall For Your Safety Read Before Lighting Lighting InstructionsMain Burner Flame Characteristics Air Shutter Adjustment FigureCleaning Main Burner Orifice and Main Burner Piezo Pilot Ignitor InstructionsPilot Flame Characteristics Thermostat OperationOxygen Depletion Sensor Pilot Figure BF-10Appliance Maintenance Troubleshooting HOW to Order Repair Parts Parts ListPart number and description of part coincide Parts View Optional Blower Installation Instructions Excessive Blower Wheel NoiseOptional Blower Installation Instructions Service Notes Belleville, Illinois

BF-30-2, BF-20-2, BF-10-2 specifications

Empire Products has established itself as a notable player in the realm of industrial solutions with its comprehensive range of BF series products, particularly the BF-30-2, BF-10-2, and BF-20-2. These models, each designed to meet various operational needs, exhibit the company’s commitment to innovation and efficiency.

The BF-30-2 is the flagship model in the series, equipped with advanced features that cater to heavy-duty applications. It boasts a robust design coupled with high-performance capabilities. One of its standout technologies includes an efficient energy management system that optimizes power consumption without compromising performance. This model also features a user-friendly interface for easy operation and monitoring, ensuring that users can quickly adapt to its functionalities. The BF-30-2 is particularly well-suited for applications requiring precision and high throughput, making it a favorite among manufacturers looking for reliability and efficiency.

Next in the lineup is the BF-20-2, which strikes a balance between power and versatility. This model is designed to handle moderate to intense workloads, making it ideal for businesses that require adaptability in their operations. It is equipped with adaptive technology that allows it to adjust its performance based on real-time operational demands. The BF-20-2 also offers enhanced safety features, ensuring that operators can work confidently and comfortably.

The BF-10-2, while smaller in capacity, should not be underestimated. It is engineered for small to medium-sized tasks, perfect for businesses that require compact solutions without sacrificing quality. This model incorporates cutting-edge materials and components designed to maximize durability and reduce maintenance needs. Additionally, the BF-10-2 is highly energy-efficient, making it an excellent choice for environmentally conscious companies looking to minimize their carbon footprint.

All three models share a few key characteristics that highlight the essence of Empire Products' engineering prowess. They are designed for easy integration into existing systems, which simplifies upgrades for businesses looking to enhance their operational capabilities. Moreover, their modular design allows for customizable configurations, catering to specific user requirements.

In conclusion, the Empire Products BF series, encompassing the BF-30-2, BF-20-2, and BF-10-2, represents the synergy of performance, innovation, and versatility. Each model serves a unique purpose, allowing businesses to select the perfect equipment to meet their operational goals while benefiting from the latest technological advancements in the industry.