WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach yourgas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

UNVENTED

ROOM HEATER

MODELS

BF-10-2 BF-20-2 BF-30-2

EFFECTIVE DATE

MAY 2004

This appliance may be installed in an after- market, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appli- ance is not convertible for use with other gases.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ven- tilation air must be provided. Refer to page 6.

WARNING: If not installed, operated and maintained in accordance with the manufacturer'sinstructions,thisproductcould expose you to substances in fuel or from fuel combustion which can cause death or serious illness.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Watervaporis a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour. Refer to page 6.

16012-1-0504

Page 1

Image 1
Contents Installation Instructions Table of Contents Air, heater may give off Carbon MONOXIDE, an odor Important Safety InformationHeater. In this type of application, a fan to circulate LP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsUnusually Tight Construction Water Vapor a BY-PRODUCT of Unvented Room HeatersPressure Testing of the Gas Supply System Installing a New Main Gas CockGAS Supply Gas SupplyClearances Optional Floor Stand InstallationOn Solid Wall Wall Mount InstallationBF-10 and BF-20 BF-30 On Sheet Rock Wall Lighting Instructions For Your Safety Read Before LightingAir Shutter Adjustment Figure Main Burner Flame CharacteristicsCleaning Main Burner Orifice and Main Burner Piezo Pilot Ignitor InstructionsThermostat Operation Pilot Flame CharacteristicsOxygen Depletion Sensor Pilot Figure BF-10Appliance Maintenance Troubleshooting HOW to Order Repair Parts Parts ListPart number and description of part coincide Parts View Excessive Blower Wheel Noise Optional Blower Installation InstructionsOptional Blower Installation Instructions Service Notes Belleville, Illinois

BF-30-2, BF-20-2, BF-10-2 specifications

Empire Products has established itself as a notable player in the realm of industrial solutions with its comprehensive range of BF series products, particularly the BF-30-2, BF-10-2, and BF-20-2. These models, each designed to meet various operational needs, exhibit the company’s commitment to innovation and efficiency.

The BF-30-2 is the flagship model in the series, equipped with advanced features that cater to heavy-duty applications. It boasts a robust design coupled with high-performance capabilities. One of its standout technologies includes an efficient energy management system that optimizes power consumption without compromising performance. This model also features a user-friendly interface for easy operation and monitoring, ensuring that users can quickly adapt to its functionalities. The BF-30-2 is particularly well-suited for applications requiring precision and high throughput, making it a favorite among manufacturers looking for reliability and efficiency.

Next in the lineup is the BF-20-2, which strikes a balance between power and versatility. This model is designed to handle moderate to intense workloads, making it ideal for businesses that require adaptability in their operations. It is equipped with adaptive technology that allows it to adjust its performance based on real-time operational demands. The BF-20-2 also offers enhanced safety features, ensuring that operators can work confidently and comfortably.

The BF-10-2, while smaller in capacity, should not be underestimated. It is engineered for small to medium-sized tasks, perfect for businesses that require compact solutions without sacrificing quality. This model incorporates cutting-edge materials and components designed to maximize durability and reduce maintenance needs. Additionally, the BF-10-2 is highly energy-efficient, making it an excellent choice for environmentally conscious companies looking to minimize their carbon footprint.

All three models share a few key characteristics that highlight the essence of Empire Products' engineering prowess. They are designed for easy integration into existing systems, which simplifies upgrades for businesses looking to enhance their operational capabilities. Moreover, their modular design allows for customizable configurations, catering to specific user requirements.

In conclusion, the Empire Products BF series, encompassing the BF-30-2, BF-20-2, and BF-10-2, represents the synergy of performance, innovation, and versatility. Each model serves a unique purpose, allowing businesses to select the perfect equipment to meet their operational goals while benefiting from the latest technological advancements in the industry.