Empire Products BF-20-2, BF-30-2, BF-10-2 Wall Mount Installation, On Solid Wall

Page 9

WALL MOUNT INSTALLATION

Refer to Figures 6 and 7 for measurements in order to locate (4) mounting holes on wall. Figures 6 and 7 are the front views of the heater.

1.Remove lower louver from casing assembly (2 screws).

2.Remove reflector from casing assembly (2 screws).

3.Remove upper louver from casing assembly (2 screws).

On Solid Wall

1.After locating mounting holes, attach (4) #10 x 1" (25mm) screws provided into the wall. Do not completely tighten screwheads to the wall, leave a 1/8" (3mm) gap between screwheads and wall.

2.Mount heater onto the (4) screwheads and complete tightening screwheads into the wall.

Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield.

a.When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield.

b.When replacing reflector, be sure the top lip of reflector goes in front of the heat shield.

3. Connect the gas line.

18"

 

 

24 1/8"

 

 

 

 

(613mm)

 

 

(457mm)

 

 

 

 

 

 

 

 

2"

14"

2"

2"

20 1/8"

2"

(511mm)

(51)

(51)

(51)

(51)

(356mm)

 

 

 

 

 

 

 

1 3/32

 

 

1 3/32"

 

 

 

 

(28mm)

 

 

(28mm)

 

 

 

 

 

 

 

 

 

187/8"

(479mm)

41/32"

(102mm) MIN

2 1/32 (52mm)

22"

(559mm)

2" (51mm)

187/8"

(479mm)

41/32

(102mm)

MIN

2 1/32" (52mm)

22"

(559mm)

2" (51mm) MIN

BF-10 and BF-20

BF-30

Figure 6

Figure 7

On Sheet Rock Wall

1. After locating mounting holes, drill (4) 5/16" (8mm) diameter holes into the wall.

2.Insert (4) plastic expansion anchors provided into the holes.

3.Tighten (4) #10 x 1" (25mm) screws provided into the plastic expansion anchors. Do not completely tighten screwheads

to the plastic expansion anchors, leave a 1/8" (3mm) gap between screwheads and plastic expansion anchors.

4.Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield.

a.When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield.

b. When replacing reflector, be sure the top lip of reflector goes in front of the heat shield.

5. Connect the gas line.

16012-1-0504

Figure 8

Page 9

 

Image 9
Contents Installation Instructions Table of Contents Important Safety Information Air, heater may give off Carbon MONOXIDE, an odorHeater. In this type of application, a fan to circulate LP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsUnusually Tight Construction Water Vapor a BY-PRODUCT of Unvented Room HeatersPressure Testing of the Gas Supply System Installing a New Main Gas CockGAS Supply Gas SupplyClearances Optional Floor Stand InstallationWall Mount Installation On Solid WallBF-10 and BF-20 BF-30 On Sheet Rock Wall Lighting Instructions For Your Safety Read Before LightingAir Shutter Adjustment Figure Main Burner Flame CharacteristicsCleaning Main Burner Orifice and Main Burner Piezo Pilot Ignitor InstructionsThermostat Operation Pilot Flame CharacteristicsOxygen Depletion Sensor Pilot Figure BF-10Appliance Maintenance Troubleshooting Parts List HOW to Order Repair PartsPart number and description of part coincide Parts View Excessive Blower Wheel Noise Optional Blower Installation InstructionsOptional Blower Installation Instructions Service Notes Belleville, Illinois

BF-30-2, BF-20-2, BF-10-2 specifications

Empire Products has established itself as a notable player in the realm of industrial solutions with its comprehensive range of BF series products, particularly the BF-30-2, BF-10-2, and BF-20-2. These models, each designed to meet various operational needs, exhibit the company’s commitment to innovation and efficiency.

The BF-30-2 is the flagship model in the series, equipped with advanced features that cater to heavy-duty applications. It boasts a robust design coupled with high-performance capabilities. One of its standout technologies includes an efficient energy management system that optimizes power consumption without compromising performance. This model also features a user-friendly interface for easy operation and monitoring, ensuring that users can quickly adapt to its functionalities. The BF-30-2 is particularly well-suited for applications requiring precision and high throughput, making it a favorite among manufacturers looking for reliability and efficiency.

Next in the lineup is the BF-20-2, which strikes a balance between power and versatility. This model is designed to handle moderate to intense workloads, making it ideal for businesses that require adaptability in their operations. It is equipped with adaptive technology that allows it to adjust its performance based on real-time operational demands. The BF-20-2 also offers enhanced safety features, ensuring that operators can work confidently and comfortably.

The BF-10-2, while smaller in capacity, should not be underestimated. It is engineered for small to medium-sized tasks, perfect for businesses that require compact solutions without sacrificing quality. This model incorporates cutting-edge materials and components designed to maximize durability and reduce maintenance needs. Additionally, the BF-10-2 is highly energy-efficient, making it an excellent choice for environmentally conscious companies looking to minimize their carbon footprint.

All three models share a few key characteristics that highlight the essence of Empire Products' engineering prowess. They are designed for easy integration into existing systems, which simplifies upgrades for businesses looking to enhance their operational capabilities. Moreover, their modular design allows for customizable configurations, catering to specific user requirements.

In conclusion, the Empire Products BF series, encompassing the BF-30-2, BF-20-2, and BF-10-2, represents the synergy of performance, innovation, and versatility. Each model serves a unique purpose, allowing businesses to select the perfect equipment to meet their operational goals while benefiting from the latest technological advancements in the industry.