Enerco HSIR20LPT, MHBF6LP, HSBF10LP, HSBF20LPT, HSIR30LPT, HSBF30LPT Lighting Instructions

Page 10

C.Use only your hand to push in or turn the gas control knob. Never use tools. It knob will not push in or turn by hand, don’t try to repair it; call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to re- place any part of the control system which has been underwater.

LIGHTING INSTRUCTIONS

1.STOP! Read the all safety information included with and on the side of heater.

2.Check that gas supply to heater is on.

3.Push in gas control knob and slightly turn clock- wise to the OFF position (see figure 16).

Note: Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly. Do not force.

4.Wait five (5) minutes. Then smell for gas, in- cluding near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you do not smell gas, go to the next step.

5.Push in gas control know slightly and turn counterclockwise to PILOT/IGN and depress for five (5) seconds.

Note: The first time that the heater is operated after connecting the gas supply, the control knob should be depressed for about 30 seconds. This will allow air to bleed from the gas system.

6.Push in control knob and rotate control knob back to OFF position then rotate counterclock- wise to PILOT/IGN position. This will light pilot. If needed gently keep rotating control knob back and forth while depressed until pilot lights.

7.Keep control knob depressed in for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 4, 5, 6 and 7.

If pilot does not stay lit, refer to Troubleshoot- ing, pages 14 & 15. Also, contact a qualified service person or gas supplier for repairs.

If control knob does not pop up when released, contact a qualified service person or gas sup- plier for repairs.

8.FOR IR10LP: When the pilot is lit, turn the con- trol knob to “LO” position to light heater. Leave on “LO” position until first burner tile has turned bright red (See figure18).

FOR BF6LP and BF10LP: When the pilot is lit, turn the control knob to “HI” position to light.

9.FOR IR10LP: After first burner tile has turned bright red, adjust heat output by turning control knob to desired position (“LO” or “HI”, figure 18). Do not operate heater between locked positions.

FOR BF6LP and BF10LP: After flame is estab- lished (see Burner Flame Pattern, Pages 12 and

13)on “HI”, adjust heat output by turning control knob to desired position (“LO” or “HI”). Do not oper- ate heater between locked positions.

Control Knob

Figure 16

Note: Your heater may have either pilot assembly.

Figure 17

CAUTION: Do not try to adjust heating level by using equipment shutoff valve.­

WARNING: When running heater, set control knob at “LO” or “HI” locked positions. Poor combustion and higher levels of carbon monoxide may result if heater is operated with control knob positioned between locked positions.­

Burner tile pattern

LOW

for IR Heaters only.

HIGH

OFF

Figure 18.

IMPORTANT: Release downward pressure while turn- ing control knob. Control knob must be locked at the desired position.

Unvented Liquid Propane Fired Room Heater

10

Installation Instructions and Owner’s Manual

Image 10
Contents TSBF30LPT TSBF20LPT HSBF10LP TSBF10LP MHIR30LPT MHIR20LPT Blue Flame Heaters­ Plaque Heaters­MHBF30LPT MHBF20LPT MHBF6LP HSBF30LPT HSBF20LPT HSIR30LPT HSIR20LPT HSIR10LP TSIR30LPT TSIR20LPT TSIR10LPCarbon Monoxide Poisoning PrecautionsPropane/LP Gas Local Codes Safety DeviceThermostatic Control on Thermostat Models Ignition SystemVentilation AIR Determining the Type of Heater Location SpaceVentilation from Inside Building Ventilation from Outdoors Installation Check GAS TypeThis Installation Requires Locating HeaterFastening Heater to Wall Mounting BracketConnecting to GAS Supply Installing Bottom Mounting ScrewsInstalling Support Feet see figure Placing Heater on Mounting BracketTest pressure in Excess of ½ psig 3.5kPa Test Pressure Equal To or Less Than ½ psig 3.5 kPaOperating Your Heater Pressure Testing Heater Gas ConnectionsElectrical Wiring Diagram What to do if YOU Smell GASLighting Instructions To Turn OFF GAS to Appliance Shutting OFF HeaterPilot Flame Pattern Thermostat Control OperationInspecting Burner Burner Flame PatternCleaning Burner Pilot AIR Hole Inlet Cleaning and MaintenanceCleaning ODS/PILOT and Burner Cleaning Heater CabinetTroubleshooting Observed SYMPTOM­ Possible CAUSE­ REMEDY­Troubleshooting CON’T Observed SYMPTOM­ Possible CAUSE­ REMEDY­IR20LPT­ IR30LPT­ SpecificationsIR10 LP­ BF6LP BF10LP­ BF20LPT BF30LPT­Unvented Liquid Propane Fired Room Heater Unvented Liquid Propane Fired Room Heater Unvented Liquid Propane Fired Room Heater Unvented Liquid Propane Fired Room Heater Unvented Liquid Propane Fired Room Heater Parts not Under Warranty REPLACEMENT­PARTSParts Under Warranty Technical ServiceUnvented Liquid Propane Fired Room Heater Warranty Information Model ­ Serial No. ­ Date Purchased ­
Related manuals
Manual 24 pages 23.88 Kb

MHBF6LP, HSBF30LPT, HSIR20LPT, HSIR30LPT, HSBF20LPT specifications

The Enerco MHBF10LP, TSBF10LP, HSBF10LP, HSBF20LPT, and TSBF20LPT are innovative heating solutions designed for both commercial and residential applications. These units are highly efficient gas-fired heaters offering versatile heating capabilities, ensuring user comfort in various settings.

The MHBF10LP is a liquid propane heater featuring a powerful output of 10,000 BTU. It operates with a direct ignition system, allowing for quick and reliable startups. Its compact design makes it suitable for smaller spaces, while the adjustable heat settings empower users to customize their warmth. The MHBF10LP boasts a safety shut-off system which enhances the overall safety of the unit.

In contrast, the TSBF10LP is engineered for portability, offering the same 10,000 BTU output but with added mobility features. It comes with a built-in carrying handle and lightweight design, making it easy to transport from one location to another. Perfect for job sites or outdoor events, it features a sturdy construction that withstands demanding environments and a direct ignition system for ease of use.

The HSBF10LP, another variant in this range, offers high-efficiency heating in a small footprint. This model stands out with its integrated fan that aids in even heat distribution. Users can quickly warm up spaces without the long wait times. Additionally, it provides options for permanent installation, making it an adaptable choice for various applications.

The HSBF20LPT and TSBF20LPT models deliver enhanced power with a heating capacity of 20,000 BTU. The HSBF20LPT focuses on high efficiency and user convenience, featuring an automatic thermostat control to maintain desired temperatures without constant adjustment. Its robust design is perfect for larger areas, ensuring consistent warmth and comfort.

On the other hand, the TSBF20LPT is portable like its 10,000 BTU counterpart but with double the capacity. Its rugged construction and portability make it ideal for both indoor and outdoor use. The unit's reliability in diverse conditions is coupled with an ease of operation, providing warmth where it's most needed.

All models in this Enerco range prioritize user safety and efficiency. Featuring built-in safety mechanisms such as flame failure protection and tip-over shut-off systems, each heater ensures safe operation. Furthermore, the robust construction and high-quality materials used in these devices promise durability, making them a worthwhile investment for long-term heating needs.

Overall, Enerco's MHBF and TSBF series heaters represent a blend of modern technology, safety features, and user-friendly designs, tailored for a variety of heating applications.