Enerco HSIR30LPT Thermostatic Control on Thermostat Models, Local Codes, Safety Device, Unpacking

Page 3

ings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

Product Features

Ignitor Button

Room Temperature

Fan

Thermometer LED

Blower

 

Switch

 

 

Control Knob

Burners

 

Grill

Heater

Cabinet

Front Panel

Figure 1

SAFETY DEVICE

This heater has a pilot with an Oxygen Depletion Sen- sor (ODS) safety shut off system. The ODS/pilot shuts off the heater if there is not enough fresh air.

IGNITION SYSTEM

PIEZO: BF6LP / BF10LP/ IR10LP – The heater is equipped with a piezo manual ignitor. This system requires no matches, batteries, or other source to light heater.

Electronic: BF20LPT/BF30LPT/IR20LPT/IR30LPT

The heater is equipped with an electronic manual ig- nitor. This system requires no matches, or other source to light heater, but does require one AA battery to oper- ate ignitor (AA Battery included).

To install or replace battery unscrew the ignitor cap (red button), insert battery positive (+) terminal up and replace cap.

(AA Battery included)

THERMOSTATIC CONTROL ON

THERMOSTAT MODELS

(BF20LPT, BF30LPT, IR20LPT and IR30LPT)

These heaters have a control valve with a thermostat sensing bulb. This results in the greatest heater comfort and may result in lower bills.

These heaters also include an electrical blower. The blower switch has three positions: MANUAL, OFF and AUTO. In AUTO, the blower will turn on and off as the heater cycles on and off. Un MANUAL, the blower will run continuously. To turn blower off, use the OFF posi- tion.

LOCAL CODES

Install and use heater with care.

Installation must conform to local codes or in the ab- sences of local codes, use the latest edition of National Fuel Gas Code ANSI Z223.1/NFPA 54.

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

FRESH AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight construction un- less provisions are provided for adequate combus- tion and ventilation air. Read the following instruc- tions to insure proper fresh air for this and other fuel-burning appliances in your home.­

ESTABLISHING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, NFPA 54/ ANSI Z223.1, Section 5.3, Air for Com- bustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

This heater must not be installed in a confined space or unusually tight construction unless provisions are pro- vided for adequate combustion and ventilation air. The information on pages 3 through 5 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

If your home meets all of the three following criteria you must provide additional fresh air. See Ventilation Air from Outdoors, page 5.

Unusually tight construction is defined as construction where:

a.Walls and ceilings exposed to the outside atmo- sphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11kg per pa-sec-m2) or less with openings gasketed or sealed and

b.Whether stripping has been added on openable win- dows and doors, and

c.Caulking or sealants are applied to areas such as joints around windows and door frames, between wall-ceiling joints, between wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

If you home does not meet all of the three criteria above, see Determing the Type of Heater Location Space, page 4.

Confined Space and Unconfined Space

The National Fuel Gas Code, NFPA 54/ ANSI Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the aggregate input rating of all appliances

Unvented Liquid Propane Fired Room Heater

3

Installation Instructions and Owner’s Manual

Image 3
Contents HSIR30LPT HSIR20LPT HSIR10LP TSIR30LPT TSIR20LPT TSIR10LP Blue Flame Heaters­ Plaque Heaters­MHBF30LPT MHBF20LPT MHBF6LP HSBF30LPT HSBF20LPT TSBF30LPT TSBF20LPT HSBF10LP TSBF10LP MHIR30LPT MHIR20LPTPrecautions Carbon Monoxide PoisoningPropane/LP Gas Ignition System Safety DeviceThermostatic Control on Thermostat Models Local CodesDetermining the Type of Heater Location Space Ventilation AIRVentilation from Inside Building Locating Heater Installation Check GAS TypeThis Installation Requires Ventilation from OutdoorsMounting Bracket Fastening Heater to WallPlacing Heater on Mounting Bracket Installing Bottom Mounting ScrewsInstalling Support Feet see figure Connecting to GAS SupplyTest Pressure Equal To or Less Than ½ psig 3.5 kPa Test pressure in Excess of ½ psig 3.5kPaWhat to do if YOU Smell GAS Pressure Testing Heater Gas ConnectionsElectrical Wiring Diagram Operating Your HeaterLighting Instructions Shutting OFF Heater To Turn OFF GAS to ApplianceBurner Flame Pattern Thermostat Control OperationInspecting Burner Pilot Flame PatternCleaning Heater Cabinet Cleaning and MaintenanceCleaning ODS/PILOT and Burner Cleaning Burner Pilot AIR Hole InletObserved SYMPTOM­ Possible CAUSE­ REMEDY­ TroubleshootingObserved SYMPTOM­ Possible CAUSE­ REMEDY­ Troubleshooting CON’TBF6LP BF10LP­ BF20LPT BF30LPT­ SpecificationsIR10 LP­ IR20LPT­ IR30LPT­Unvented Liquid Propane Fired Room Heater Unvented Liquid Propane Fired Room Heater Unvented Liquid Propane Fired Room Heater Unvented Liquid Propane Fired Room Heater Unvented Liquid Propane Fired Room Heater Technical Service REPLACEMENT­PARTSParts Under Warranty Parts not Under WarrantyUnvented Liquid Propane Fired Room Heater Model ­ Serial No. ­ Date Purchased ­ Warranty Information
Related manuals
Manual 24 pages 23.88 Kb

MHBF6LP, HSBF30LPT, HSIR20LPT, HSIR30LPT, HSBF20LPT specifications

The Enerco MHBF10LP, TSBF10LP, HSBF10LP, HSBF20LPT, and TSBF20LPT are innovative heating solutions designed for both commercial and residential applications. These units are highly efficient gas-fired heaters offering versatile heating capabilities, ensuring user comfort in various settings.

The MHBF10LP is a liquid propane heater featuring a powerful output of 10,000 BTU. It operates with a direct ignition system, allowing for quick and reliable startups. Its compact design makes it suitable for smaller spaces, while the adjustable heat settings empower users to customize their warmth. The MHBF10LP boasts a safety shut-off system which enhances the overall safety of the unit.

In contrast, the TSBF10LP is engineered for portability, offering the same 10,000 BTU output but with added mobility features. It comes with a built-in carrying handle and lightweight design, making it easy to transport from one location to another. Perfect for job sites or outdoor events, it features a sturdy construction that withstands demanding environments and a direct ignition system for ease of use.

The HSBF10LP, another variant in this range, offers high-efficiency heating in a small footprint. This model stands out with its integrated fan that aids in even heat distribution. Users can quickly warm up spaces without the long wait times. Additionally, it provides options for permanent installation, making it an adaptable choice for various applications.

The HSBF20LPT and TSBF20LPT models deliver enhanced power with a heating capacity of 20,000 BTU. The HSBF20LPT focuses on high efficiency and user convenience, featuring an automatic thermostat control to maintain desired temperatures without constant adjustment. Its robust design is perfect for larger areas, ensuring consistent warmth and comfort.

On the other hand, the TSBF20LPT is portable like its 10,000 BTU counterpart but with double the capacity. Its rugged construction and portability make it ideal for both indoor and outdoor use. The unit's reliability in diverse conditions is coupled with an ease of operation, providing warmth where it's most needed.

All models in this Enerco range prioritize user safety and efficiency. Featuring built-in safety mechanisms such as flame failure protection and tip-over shut-off systems, each heater ensures safe operation. Furthermore, the robust construction and high-quality materials used in these devices promise durability, making them a worthwhile investment for long-term heating needs.

Overall, Enerco's MHBF and TSBF series heaters represent a blend of modern technology, safety features, and user-friendly designs, tailored for a variety of heating applications.