WTC 600 LP / MP | Version 06/05 | Maintenance and Care |
|
|
|
If the metering container was com- pletely empty, the metering pump (29) may have possibly drawn in air. In this case, bleed the air from the pump as described in Section 3.2.3.
3.1.3Switching On the Equipment
•Check if the pumps of the metering station, sand and activated carbon filter are connected to the respective power outlets (18 / 19) at the switch box (8).
•Check if the operating mode switch (9) is in the correct position “Automatic” or “Hand”.
In the “Automatic” operating mode, the i system is controlled via an external float
switch in the drinking water tank.
In the “Hand” operating mode, the sys- tem is switched on and off manually via the main switch.
•Switch the main switch (20) to the “I” position; the system starts the drinking water produc- tion.
3.1.4Operating Indicators
Display of the controls (3 / 4) of the sand and acti- vated carbon filters:
•Display of the time
•LED line: Display of the weekday
Control of the RO system:
The following is alternately indicated on the
•Equipment/model No. and operating condition,
•Drinking water temperature and drinking water conductance value,
•Operating hours (_ _ _ _ _h _ _min).
5