WTC 600 LP / MP | Version 06/05 | Malfunctions |
|
|
|
5 Malfunctions
Malfunctions of the RO system are signaled with LEDs at the control panel (10) and indicated at the display.
i | In case of a malfunction, the system is generally switched off and the drinking water production | ||
is interrupted. |
|
| |
If the malfunction can not be corrected, stop the drinking water production and notify the | |||
| Kärcher Service. |
|
|
|
|
|
|
| Designation/Indication | Possible Cause | Corrective Action |
|
|
|
|
LED | fault | Metering container empty | Fill metering container and ac- |
|
|
| knowledge malfunction after- |
|
| Sensor signal missing | wards |
|
| Kärcher Service | |
|
|
| |
|
|
|
|
| regeneration | Flushing of the | Not required, as the system |
|
|
| switches on again automatically |
|
|
|
|
| tank full | Drinking water tank full | Not required, as the system |
|
|
| switches on again automatically |
|
| Switch defective | Check switch; |
|
|
| if required, Kärcher Service |
|
|
|
|
Display | CV exceeded | Conductance value of the | Kärcher Service |
|
| drinking water too high |
|
|
|
|
|
| Hard water | Metering container empty | Fill metering container and |
|
|
| acknowledge malfunction after- |
|
|
| wards |
|
|
|
|
| Pressure malfunction | Pressure of untreated water | Check untreated water supply |
|
| too low | • Installation on building side |
|
|
| |
|
|
| • |
|
|
| • Hoses for untreated water |
|
|
|
|
Malfunctions on the
Indication | Possible Cause | Corrective Action |
|
|
|
Red LED lights | Untreated water supply | Check and reestablish the untreated |
| disconnected | water supply. |
|
| After correcting the malfunction, |
|
| press the “Reset” pushbutton (23). |
|
|
|