Karcher A 2011201 manual During Operation, Control and Corrective Action Intervals

Page 18

Maintenance and Care

Version 06/05

WTC 600 LP / MP

 

 

 

3.2During Operation

Drinking water quality is ensured only when the following control intervals are met. In case deviations from the desired condition can not be eliminated through the measures mentioned, the drinking water production must be stopped and the Kärcher Service must be notified.

3.2.1Control and Corrective Action Intervals

d…daily, w…weekly, m… monthly

Interval

Check/Activity

Target/Purpose

In Case of Deviation

 

 

 

 

d

Level, metering container

Sufficient amount/filling

Fill up; mixing chemi-

 

 

 

cals,

 

 

 

see Section 3.2.6

 

 

 

 

 

Air bubbles in metering line

No air bubbles

Bleed metering pump,

 

 

 

see Section 3.2.3

 

 

 

 

 

Flow of drinking water

Reduction of the drinking water

Fine adjustment,

 

based on the operational start-up value

flow up to 10 %

see Section 3.2.5 (1)

 

 

 

 

 

Drinking water conductance value

Increase of the drinking water

Fine adjustment,

 

based on the operational start-up value

conductance value up to 10 %

see Section 3.2.5 (2)

 

 

 

 

 

Pressure difference between pump

15 % maximum above start-up

See Section 3.2.5 (3)

 

and concentrate pressure

difference

Kärcher Service

 

 

 

 

 

Hour meter for sand und activated

Backwashing has occurred

Kärcher Service

 

carbon filter *

within the past 24 h

 

 

Pressure difference, fine filter

0,8 bar

Replace fine filter,

 

 

 

see Section 3.2.4

 

 

 

 

 

Visual inspection of the equipment

No leakage

Kärcher Service

 

 

 

 

w

Fill out operating log

 

 

 

 

 

 

m

Clean and flush the metering

 

 

 

container

 

 

 

 

 

 

 

Visually check the untreated water

No damages/leaks detectable

Kärcher Service

 

pump

 

 

 

 

 

 

 

Float switch in the drinking water

No operational malfunctions

Kärcher Service

 

tank

detectable

 

 

 

 

 

* for switching over the indication, see Section 3.2.2

3.2.2Sand and Activated Carbon Filter

During operation, the sand and activated carbon filter control indicates the actual time. To change the indication:

Press button (32) for approx. 5 s; the display (31) indicates the time of the regeneration.

Press button (32) briefly; the display indicates the number of regenerations.

Press the ADVANCE key button briefly; the display indicates the number of days and hours since the last regeneration.

6

Image 18
Contents Waterclean 600 LP / MP WTC 600 LP / MP Version 06/05Inhaltsverzeichnis SicherheitshinweiseBestimmungsgemäßer Gebrauch AnlagenelementeBedienung und Pflege Bedienung und PflegeInbetriebnahme Dosierstationen befüllenBetriebsanzeigen Während des BetriebesAnlage einschalten Kontroll- und AufgabenintervalleDie Entlüftungsschraube 34 eine Umdrehung Sand- und AktivkohlefilterDosierpumpe entlüften ÖffnenGesunken Feinfilter wechselnTrinkwasserfluss von auf Feinregulierung der BetriebsdrückeLeitfähigkeit des Trinkwassers von Auf µS/cm gestiegen Chemie anmischenDosiertabelle Verbrauchsmaterial Anlage ausschaltenDosierung Störungen StörungenAbmessungen H x B x T Technische DatenWTC 600 LP / MPVersion 06/05Technische Daten Gewicht Lieferzustand ohne FilterfüllungenEG Konformitätserklärung EG KonformitätserklärungNormen DIN Operating Instructions WTC 600 LP / MP Intended Use Safety NotesContents Equipment ComponentsStarting Operation Maintenance and CareMaintenance and Care Filling the Metering StationsSwitching On the Equipment Operating IndicatorsDuring Operation Control and Corrective Action IntervalsSand and Activated Carbon Filter Bleeding the Metering Pump Replacing the Fine FilterFine Adjustment of the Operating Pressures Flow of drinking water has decreased from to l/hMixing the Chemicals Metering TableConsumption Materials Switching Off the EquipmentConsumption Materials Metered AdditionMalfunctions MalfunctionsTechnical Data Technical DataVersion 06/05WTC 600 LP / MPEU Declaration of Conformity EU Declaration of Conformity