Notification switch settings:

Off – In this mode when a Sensor is activated, the Control Center will issue a visual Alert only (flashing Zone LED indicator), no audio will be heard.

The LED indicator will continue to flash as long as the Sensor is activated (door or window is open, garage door is up, etc.)

Chime – In this mode when a Sensor is activated, the Control Center will issue a two-tone chime sound. In addition, a visual Alert (flashing Zone LED indicator) will continue as long as the Sensor is activated (open).

Note: A Motion Sensor in Zones 1, 2 or 3 will not respond in the Chime mode. It only functions as an Alarm Sensor.

Alert – (Beeping sound) In this mode when a Sensor is activated, the Control Center will issue a continuous Alert (beeping sound) and a visual Alert (flashing Zone LED indicator). Both the flashing LED indicator and the beep sound will continue until Sensor is deactivated (door or window is closed, etc.). The number of beeps will be determined by which Zone has an activated Sensor.

Zone 1 - you will hear “1 beep…1 beep…1 beep, etc”. Zone 2 - you will hear “2 beeps…2 beeps…2 beeps, etc”. If a Sensor in more than one Zone is triggered, (i.e. Zone 1 and Zone 2 then you will hear “1 beep…2 beeps…, 1 beep… 2 beeps, etc.” )

Note: A Motion Sensor in Zones 1, 2 and 3 will not respond in the Alert mode. It only functions as an Alarm Sensor. A Motion

Sensor can be used for an Alert in Zone 4 only.

Mute – Use this button, while in Alert mode, to temporarily stop the continuous beeping Alert (e.g.

a window open or leaving the garage door up). To activate mute for a certain Zone, press the Mute button after the beeping starts. All triggered Sensors in the Zone will be muted and the LED indicator will continue to flash until the Sensor has been reset. To deactivate the mute, reset the Sensor (close door or window, lower garage door, remove water, etc) for that Zone. If more than one Zone has a triggered Sensor, pressing the Mute button will mute all triggered Zones.

Mode 2 - Dedicated Alert Mode - Zone 4 is a dedicated Zone for alerts only; it is designed for continuous monitoring. It works independently of the Notification Mode switch and the Alarm System. Sensors in Zone

4 will not trigger an alarm (HOME or AWAY). Sensors in Zone 4 do not respond to the Off/Chime/Alert Notification Mode switch.

Mode 3 - Armed/Alarm Mode (Zones 1,2,3)

Arm HOME (Instant alarm) – In this setting the alarm is instant (no delay) when a Sensor is triggered. All Sensors (except Motion Sensors) in Zones 1, 2, and 3 will trigger the alarm. Sensors in Zone 4 will not trigger the alarm. Zone 4 is for Alerts only.

Arm AWAY (Delayed alarm) – In this setting there is a 45 second exit delay before system is armed. This allows time to leave the protected area. There is also a 30 second entry delay; this allows time to enter the protected area and disarm the system before alarm sounds. All Sensors in Zones 1, 2, and 3 will trigger the alarm. Sensors in Zone 4 will not trigger the alarm. Zone 4 is for Alerts only.

Disarm – Entering the 4 digit Security Code anytime the system is armed, will immediately disarm the system, regardless of HOME or AWAY setting.

Image 7
Contents Control Center Table of Contents Precautions Important safeguardsThis system will help alleviate those concerns Features Battery Back-up Control Center Zone IndicatorsKeypad Operations Choice Alert System operates in three different modes Low Battery Indicator SensorsAll Sensors in the Zone Mode 3 Armed/Alarm Mode Zones 1,2,3 Notification switch settingsCreating a Personal Security Code Wireless performanceQuick Reference Card Lets get startedSensors and Zones Step Press and hold the Learn button unit will beepOnly one Sensor can be assigned at a time To the batteryHere are Some examples of possible Sensor/Zone combinations Assigning a Sensor to a ZoneRelease all buttons Testing a Sensor or your systemRelease the Zone button Activate the Sensor Erasing a Sensor from a ZoneTo set system in Away mode To set the system in Home modeDisarming the System Bypass a Zone For all Zones and Modes Accessories Silent Alert, Alarm Siren Signal RepeaterAdding a Silent Alert Adding a Signal Repeater Alarm SirenAdding a Alarm Siren Test the Alarm SirenPage See pg.11 in manual Choice Alert Control Center F.A.Q.’SIs reset beeping will start again when Sensor/door is opened FCC Warning Page Risk of personal injury Battery Warning

45129 specifications

The GE 45129 is an advanced locomotive model developed by General Electric, designed for efficient and versatile freight transport. Among its main features, the GE 45129 boasts a powerful engine that provides high levels of tractive effort, making it suitable for hauling heavy freight loads across various terrains. This model is specifically engineered to navigate both urban and rural rail networks, ensuring reliability in different operational environments.

One of the standout technologies incorporated into the GE 45129 is its state-of-the-art diesel-electric propulsion system. This system uses a diesel generator to produce electricity, which then powers electric traction motors on the locomotive's wheels. This configuration enhances fuel efficiency compared to traditional diesel drives, as it allows for better energy management and reduced emissions. Furthermore, the locomotive is equipped with advanced data analytics and monitoring systems that continuously assess performance metrics, helping operators optimize their use and maintenance schedules.

The GE 45129 features a robust and durable construction, designed to withstand the rigors of freight transportation. It includes high-quality materials that enhance its durability and longevity, ensuring that it remains operational even in challenging conditions. The locomotive's streamlined design not only improves its aerodynamics, leading to better fuel efficiency but also minimizes wear and tear on tracks.

In terms of safety and control, the GE 45129 includes sophisticated braking systems and technologies that provide efficient stopping power, increasing safety margins when transporting cargo. It also contains advanced signaling and communication systems that keep the train connected to central control units, allowing for real-time updates on operational status.

Additionally, this locomotive model is designed with operator comfort in mind. The cab interior is ergonomically designed, minimizing fatigue during long hauls while incorporating technology for easy navigation and monitoring of systems. This focus on user experience ensures that train operators can maintain high levels of performance and safety throughout their journeys.

Overall, the GE 45129 represents a significant advancement in locomotive technology, making it a vital asset for freight companies seeking reliability, efficiency, and safety in their operations.