Field Controls 46511500, UV-16/120 installation instructions

Page 4

4.Cut out the large opening (112" hole) on the template. (See Figure 3)

5.Using a 14" to 12" drill bit, drill a viewport hole as indicated on the template. (See Figure 3)

6.Optional Light Shield: The light shield may be mounted at virtually any angle. However, when deciding on a suitable location, the mounting screw head can not be in the shaded area of template. (See Figure 4)

7.Press shield onto duct wall then secure with screws. (See Figure 5)

8.Attach the UV-Aire mounting base onto the plenum with the supplied sheet metal screws. (Refer to template shown in Figure 3) This must be tight in order to activate the built in safety switch.

NOTE: DO NOT remove template from duct.

Head of mounting screw CAN NOT be located in shaded area

Figure 4

Figure 3

Figure 5

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.

page 4

Image 4
Contents UV-AIREAIR Purifying System Items Included in KITSafety Considerations Installation General InformationPage Page Maintenance Replacement ProcedureTroubleshooting Guide Replacement Parts ListLimited Warranty