Adams Condensing Oil-Fired Furnace operation manual System and General Troubleshooting

Page 22

Table 1

System and General Troubleshooting

 

 

 

PROBLEM

POSSIBLE CAUSE

REMEDY

 

Electrodes out of adjustment or defective.

Check etectrode settings. Check electrodes for dirt build-up or cracks in porcelain.

 

Poor transformer high voltage connections

Check contacts between the igniter and electrodes. If OK, replace the Igniter.

Oilbumer

or defective transformer.

 

Fuel oil filter cloaaed.

Replace fuel oil storage tank filter and/or fuel oil in-line filter.

sputtering at

 

 

nozzle

Defective 011 pump.

Check burner motor/fuel oil pump coupling. Check oil pump pressure. Replace fuel oil

 

 

pump if necessary.

 

Fuel oil line partially clogged or contains

Bleed air from oil line.

 

air.

If Dl'obIem persists, replace oliline.

 

System temperature rise too high.

"Refer to start up procedure for correct temperature rise. Check for clogged air filters.

 

 

Check blower fan for excess dirt build-up or debris. Speed up blower fan if necessary.

 

 

 

 

Poor "fan off' delay timing selection, (fan

Check "fan off' delay timing setting for a delay off between 390 and 600 seconds.

Check stack

stoes too soon) Fan controi timer.

 

 

 

temperature.

Fuel 011 leak.

Check fuel 011 line for leaks. Repair or replace if necessary.

 

 

 

 

Stack temperature too high.

Check stack temperature. Stack temperatures will normally range from 20-42 degrees

 

 

above ambient.

 

 

 

 

Thermostat Improperly adjusted or in poor

Check thermostat heat anticipator setting against measured amperage draw. Increase

 

location.

heat anticipator setting if necessary. If the thermostat is being influenced by drafts,

 

 

sunlight duct work etc. relocate to more suitable location.

More than (0)

Insufficient combustion air at oil burner

Adjust oil burner combustion air to gain the highest C02 or lowest practical 02 content

 

In the flue gas (see Burner Set Up).

smoke

 

 

 

 

 

 

 

Heat exchanaer oartiallv blocked

Check for soot build UP In turbulators of secondary heat exchanaer

 

Poor alignment of between oil burner blast

Check alignment. Blast tube should be centered with fire pot burner opening. Oil burner

Soot build up on

tube and fire pot.

head should be % Inch back from the inside surface of the fire pot.

 

 

the blast tube

Flame impingement caused by incorrect

 

(end coning).

nozzle angle.

Check noZ'ZIe size and anale. Check distance from head to inside surface of the fire pet.

 

 

 

 

Defective fire DOt.

Check fire DOt. Reoair or reolace.

 

Airflow blocked or dirty air filter.

Clean or replace air filter.

 

 

 

 

 

Check thermostat heat anticipator setting against measured amperage draw. Increase

 

Thermostat adjustments or location.

heat anticipator setting if necessary. If the thermostat is being influenced by drafts,

 

 

sunlight, duct work, etc., relocate to more suitable location.

 

 

 

 

Insufficient airflow.

Check all dampers. Open closed dampers including registers in unused rooms. Check

Furnace will not

 

system temperature rise. If temperature rise is too high, speed up blower fan.

 

 

wannhometo

 

 

desired

Defective high limit control.

Test high limit function of all limit switches. Use a duct thermometer to assess accuracy

temperature.

 

of limit control. Check for obstructions to airflow around limit switch bi-metal elements.

 

 

Replace control if necessary. NOTE: A. high limit Is auto-reset. B. Auxiliary limit is

 

 

manual re-6et.

 

Under-sized nozzle.

Check nozzle. If problem is not caused by air flow problems, use larger nozzle, If

 

 

permitted by rating Dlate.

 

Blower fan motor stopping intermittently

Check blower fan motor amperage draw. Check motor ventilation ports, clean if

 

on overload

necessary. Reolace motor if necessary.

 

Burner motor stopping intermittently on

Check burner motor. Replace if necessary

 

overload.

 

21

Image 22
Contents Condensing Oil-Fired Furnace Table of Contents 1m ortant Keep this literature in a safe place for future reference To The InstallerTransportation Damage III. Product Application IV. Location Requirements & Considerations GeneralClearances and Accessibility Combustion and Ventilation Air Thermostat LocationExisting Furnace Removal VI. VENT/FLUE Pipe Combustion AIR PipeTermination Locations Exhaust VENT/INLET AIR Sidewall Vent System Ventiflue Pipe Standard Furnace ConnectionsVentiflue and Combustion AIR Pipe Lengths Direct Vent Dual Pipe Piping ­ Beckett NX NON-DIRECT Vent Dual Pipe INTERburnerVII. Electrical Connections Wiring HarnessVolt Line Connections Thermostat HI­ MEO- WE120 AIR .... --- .. J 24V Terminal 120V Terminal Strip STR1PVIII. Condensate Drain Lines Drain Trap Drain Trap AssemblyDrain Connection IX. OIL Line Piping InstallationOIL Tank Circulating AIR & Filters OIL LinesXI. START-UP Procedure & Adjustment Your final C02% should be approximately 11.5% Temperature RiseTemperature Rise Measurement Model Temp. F Degree RisePower UP Mode Thermostat SatisfiedSystem and General Troubleshooting Problem Possible Cause RemedySystem and General Troubleshooting XIV. Maintenance &Annual Inspection Item No Description Tons Cooling Furnace Assembly Drawing

Condensing Oil-Fired Furnace specifications

The Adams Condensing Oil-Fired Furnace is a leading choice for homeowners seeking an efficient and reliable heating solution. Known for its advanced technology and outstanding performance, this furnace is designed to provide comfort during the coldest months while maximizing energy efficiency.

One of the main features of the Adams Condensing Oil-Fired Furnace is its high-efficiency heating capabilities. Equipped with a condensing heat exchanger, it utilizes combustion gases that would otherwise be wasted. This allows the furnace to achieve efficiency ratings of up to 90 percent or higher, making it one of the most efficient options on the market. This not only reduces energy consumption but also lowers heating costs for homeowners.

The furnace is designed with a robust construction that ensures durability and longevity. The unit is made from high-quality materials resistant to corrosion and wear. This is particularly important in environments where the furnace may be exposed to fluctuating temperatures and humidity levels. The furnace also has advanced insulation, minimizing heat loss and further enhancing its efficiency.

Another significant characteristic of the Adams Condensing Oil-Fired Furnace is its quiet operation. The unit is engineered with sound-absorbing materials and an advanced blower design, allowing it to operate quietly. This feature is particularly desirable for those who value peace and tranquility in their homes.

The furnace employs advanced control technology that allows for precise temperature management. Homeowners can benefit from programmable thermostats that enable them to customize heating schedules to suit their lifestyle. This not only ensures comfort but also promotes energy savings by allowing the system to operate only when needed.

In addition to its efficiency and performance, the Adams Condensing Oil-Fired Furnace is designed with safety in mind. The unit incorporates a range of safety features, including flame sensors and automatic shut-off systems that provide peace of mind for users.

Overall, the Adams Condensing Oil-Fired Furnace stands out as a premium heating solution, combining efficiency, reliability, and advanced features. With its commitment to energy savings and user comfort, this furnace is an excellent investment for any homeowner looking to enhance their heating system.