Adams Condensing Oil-Fired Furnace operation manual III. Product Application

Page 5

III. PRODUCT APPLICATION

This furnace is primarily designed for residential home-heating applications. It is NOT designed or certified for use in mobile home, trailers or recreational vehicles. This unit is NOT designed or certified for outdoor applications. The furnace must be installed indoors (i.e., attic space, crawl space, or garage area prOVided the garage area is enclosed with an operating door).

This furnace can be used in the following non-industrial commercial applications:

Schools, Office buildings, Churches, Retail stores, Nursing homes, Hotels/motels, common or office areas In such applications, the furnace must be installed with the following stipulations:

oIt must be installed per the installation instructions provided and per local and national codes.

oIt must be installed indoors in a building constructed on site.

oIt must be part of a ducted system

and not used in a free air delivery application.

oIt must not be used as a "make-up"

air unit.

oThis furnace may NOT be used as a construction site heater.

To ensure proper installation and operation, thoroughly read this manual for specifics pertaining the installation and application of this roduct.

rWARNING

Possible property damage, personal injury or death due to fire, explosion, smoke, soot, condensation, electrical shock or carbon monoxide may result from improper installation, repair, operation or maintenance of this product.

rWARNING

To prevent personal injury, property damage or death due to fire, do not install this furnace in a mobile home, trailer or recreational vehicle.

To ensure proper fumace operation, install, operate and maintain the furnace in accordance with these installation and operation instructions, all local building codes and ordinances.

INSTALLATION CODES

INSTALLATION MUST COMPLY WITH THE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION.

All local and national codes governing the installation of oil burning equipment, Wiring, and venting must be followed. Some of the applicable codes are:

CAN/CSA B139 Installation Code for Oil Burning EqUipment.

NFPA 31 Installation Code for oil Burning Equipment

ANSIINFPA 90B Warm Air Heating and Air Conditioning Systems.

ANSIINFPA 70 National Electrical Code. CSA C22.1 Canadian Electrical Code. ANSI/NFPA 211 Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances.

A copy of the CAN/CSA B139 Installation Codes can be obtained from:

CSA International

178 Rexdale Boulevard

Etobicoke, Ontario, Canada M9WIR3

or

CSA International

8501 East Pleasant Valley

Cleveland, OH 44131

The rated heating capacity of the furnace should be greater than or equal to the total heat loss of the area to be heated. The total heat loss should be calculated by an approved method or in accordance with "ASHRAE Guide" or "Manual J-load Calculations" published by the Air Conditioning Contractors of America.

IV. LOCATION REQUIREMENTS & CONSIDERATIONS

GENERAL

rWARNING

TO PREVENT POSSIBLE EQUIPMENT DAMAGE, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, THE FOLLOWING BULLET POINTS MUST BE OBSERVED WHEN INSTALLING THE UNIT.

4

Image 5
Contents Condensing Oil-Fired Furnace Table of Contents 1m ortant Transportation Damage To The InstallerKeep this literature in a safe place for future reference IV. Location Requirements & Considerations General III. Product ApplicationClearances and Accessibility Thermostat Location Combustion and Ventilation AirVI. VENT/FLUE Pipe Combustion AIR Pipe Existing Furnace RemovalTermination Locations Exhaust VENT/INLET AIR Sidewall Vent System Ventiflue and Combustion AIR Pipe Lengths Standard Furnace ConnectionsVentiflue Pipe NON-DIRECT Vent Dual Pipe INTERburner Direct Vent Dual Pipe Piping ­ Beckett NXVolt Line Connections Wiring HarnessVII. Electrical Connections 120 AIR .... --- .. J MEO- WEThermostat HI­ 24V Terminal 120V Terminal Strip STR1PDrain Connection Drain Trap AssemblyVIII. Condensate Drain Lines Drain Trap OIL Tank Piping InstallationIX. OIL Line OIL Lines Circulating AIR & FiltersXI. START-UP Procedure & Adjustment Temperature Rise Measurement Temperature RiseYour final C02% should be approximately 11.5% Model Temp. F Degree RiseThermostat Satisfied Power UP ModeProblem Possible Cause Remedy System and General TroubleshootingSystem and General Troubleshooting XIV. Maintenance &Annual Inspection Item No Description Tons Cooling Furnace Assembly Drawing

Condensing Oil-Fired Furnace specifications

The Adams Condensing Oil-Fired Furnace is a leading choice for homeowners seeking an efficient and reliable heating solution. Known for its advanced technology and outstanding performance, this furnace is designed to provide comfort during the coldest months while maximizing energy efficiency.

One of the main features of the Adams Condensing Oil-Fired Furnace is its high-efficiency heating capabilities. Equipped with a condensing heat exchanger, it utilizes combustion gases that would otherwise be wasted. This allows the furnace to achieve efficiency ratings of up to 90 percent or higher, making it one of the most efficient options on the market. This not only reduces energy consumption but also lowers heating costs for homeowners.

The furnace is designed with a robust construction that ensures durability and longevity. The unit is made from high-quality materials resistant to corrosion and wear. This is particularly important in environments where the furnace may be exposed to fluctuating temperatures and humidity levels. The furnace also has advanced insulation, minimizing heat loss and further enhancing its efficiency.

Another significant characteristic of the Adams Condensing Oil-Fired Furnace is its quiet operation. The unit is engineered with sound-absorbing materials and an advanced blower design, allowing it to operate quietly. This feature is particularly desirable for those who value peace and tranquility in their homes.

The furnace employs advanced control technology that allows for precise temperature management. Homeowners can benefit from programmable thermostats that enable them to customize heating schedules to suit their lifestyle. This not only ensures comfort but also promotes energy savings by allowing the system to operate only when needed.

In addition to its efficiency and performance, the Adams Condensing Oil-Fired Furnace is designed with safety in mind. The unit incorporates a range of safety features, including flame sensors and automatic shut-off systems that provide peace of mind for users.

Overall, the Adams Condensing Oil-Fired Furnace stands out as a premium heating solution, combining efficiency, reliability, and advanced features. With its commitment to energy savings and user comfort, this furnace is an excellent investment for any homeowner looking to enhance their heating system.