Adams Condensing Oil-Fired Furnace operation manual To The Installer, Transportation Damage

Page 4

I WARNING

WE WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES. IF YOU INSTALL OR PERFORM SERVICE ON THIS UNIT, YOU ASSUME RESPONSIBILLITY FOR ANY PERSONAl

INJURY OR PROPERTY DAMAGE WHICH MAY RESULT. MANY JURISDICTIONS REQUIRE A LICENSE TO INSTALL OR SERVICE HEATING AND AIR CONDITIONING EQUIPMENT.

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR FUEL OIL DEALER.

DANGER

PELIGRO

CARBON MONOXIDE

POISONING HAZARD

To The Installer

Before installing this unit, please read this manual thoroughly to familiarize yourself with specific items which must be adhered to, including, but not limited to: unit maximum external static pressure, oil pressure, BTU input rating, proper electrical connections, circulating air temperature rise, minimum or maximum CFM, and motor speed connections. '

TRANSPORTATION DAMAGE

All units are securely packed in shipping containers tested according to International SafeTransit Association specifications.

The carton must be checked upon arrival for external damage. If damage is found, a request for inspection by carrier's agent must be made in writing immediately.

1.Make a notation on delivery receipt of any visible damage to shipment or container.

2.Notify carrier promptly and request an inspection.

3.With concealed damage, carrier must be notified as soon as possible - preferably within five days.

4.File the claim with the following support documents within a nine month statute of limitations.

o Original or certified copy of the Bill of Lading, or indemnity bond.

o Original paid freight bill or indemnity in lieu thereof.

o Original or certified copy of the invoice, showing trade and other discounts or reductions.

o Copy of the inspection report issued by carrier's representative at the time damage is reported to carrier.

The carrier is responsible for making prompt inspection of damage and for a thorough investigation of each claim. The distributor or manufacturer will not accept claims from dealers for transportation damage.

Keep this literature in a safe place for future reference.

3

Image 4
Contents Condensing Oil-Fired Furnace Table of Contents 1m ortant Keep this literature in a safe place for future reference To The InstallerTransportation Damage III. Product Application IV. Location Requirements & Considerations GeneralClearances and Accessibility Combustion and Ventilation Air Thermostat LocationExisting Furnace Removal VI. VENT/FLUE Pipe Combustion AIR PipeTermination Locations Exhaust VENT/INLET AIR Sidewall Vent System Ventiflue Pipe Standard Furnace ConnectionsVentiflue and Combustion AIR Pipe Lengths Direct Vent Dual Pipe Piping ­ Beckett NX NON-DIRECT Vent Dual Pipe INTERburnerVII. Electrical Connections Wiring HarnessVolt Line Connections MEO- WE 120 AIR .... --- .. JThermostat HI­ 24V Terminal 120V Terminal Strip STR1PVIII. Condensate Drain Lines Drain Trap Drain Trap AssemblyDrain Connection IX. OIL Line Piping InstallationOIL Tank Circulating AIR & Filters OIL LinesXI. START-UP Procedure & Adjustment Temperature Rise Temperature Rise MeasurementYour final C02% should be approximately 11.5% Model Temp. F Degree RisePower UP Mode Thermostat SatisfiedSystem and General Troubleshooting Problem Possible Cause RemedySystem and General Troubleshooting XIV. Maintenance &Annual Inspection Item No Description Tons Cooling Furnace Assembly Drawing

Condensing Oil-Fired Furnace specifications

The Adams Condensing Oil-Fired Furnace is a leading choice for homeowners seeking an efficient and reliable heating solution. Known for its advanced technology and outstanding performance, this furnace is designed to provide comfort during the coldest months while maximizing energy efficiency.

One of the main features of the Adams Condensing Oil-Fired Furnace is its high-efficiency heating capabilities. Equipped with a condensing heat exchanger, it utilizes combustion gases that would otherwise be wasted. This allows the furnace to achieve efficiency ratings of up to 90 percent or higher, making it one of the most efficient options on the market. This not only reduces energy consumption but also lowers heating costs for homeowners.

The furnace is designed with a robust construction that ensures durability and longevity. The unit is made from high-quality materials resistant to corrosion and wear. This is particularly important in environments where the furnace may be exposed to fluctuating temperatures and humidity levels. The furnace also has advanced insulation, minimizing heat loss and further enhancing its efficiency.

Another significant characteristic of the Adams Condensing Oil-Fired Furnace is its quiet operation. The unit is engineered with sound-absorbing materials and an advanced blower design, allowing it to operate quietly. This feature is particularly desirable for those who value peace and tranquility in their homes.

The furnace employs advanced control technology that allows for precise temperature management. Homeowners can benefit from programmable thermostats that enable them to customize heating schedules to suit their lifestyle. This not only ensures comfort but also promotes energy savings by allowing the system to operate only when needed.

In addition to its efficiency and performance, the Adams Condensing Oil-Fired Furnace is designed with safety in mind. The unit incorporates a range of safety features, including flame sensors and automatic shut-off systems that provide peace of mind for users.

Overall, the Adams Condensing Oil-Fired Furnace stands out as a premium heating solution, combining efficiency, reliability, and advanced features. With its commitment to energy savings and user comfort, this furnace is an excellent investment for any homeowner looking to enhance their heating system.