Bryant 310AAV, 310JAV warranty Upflow Return Air Configurations and Restrictions

Page 15

Fig. 18—Upflow Return Air Configurations and Restrictions

A02075

Fig. 19—Downflow Return Air Configurations and Restrictions

A02163

A02162

Fig. 20—Horizontal Return Air Configurations and Restrictions

14

Image 15
Contents 310AAV/JAV Induced-Combustion 4-Way Multipoise Furnace Table of Contents Safety Considerations → -Dimensional Drawing→ -Clearances to Combustibles InstallationDimensions IntroductionCodes and Standards Location → Electrostatic Discharge ESD Precautions ProcedureLocation Relative to Cooling Equipment AIR for Combustion and VentilationBtuh Minimum Free Area of Combustion Air OpeningUnconfined Space Confined SpaceVentilation from Outdoors Downflow InstallationInstallation Upflow InstallationHorizontal Installation Filter ArrangementAir Ducts Floor and Plenum Opening Dimensions Furnace Plenum Opening Floor Opening Casing Opening Dimensions→ -Duct Flanges Ductwork Acoustical TreatmentSupply AIR Connections → -Horizontal Unit Suspension22″ Return AIR ConnectionsGas Piping 17 3/4″Upflow Return Air Configurations and Restrictions → -Maximum Capacity of Pipe → a-Right Side Gas Entry ExampleNominal Length of Pipe FT Iron Internal Diameter Size BOX Relocation WiringFor Power Cord Installation → -Electrical DataFor BX Cable Installation BOX Cover InstallationAccessories Venting Masonry Chimney Requirements Carbon Monoxide Poisoning HazardNgpic General Venting Requirements NscngpicVent Internal Area of Chimney Sidewall Venting START-UP, ADJUSTMENT, and Safety CheckAppliance Application Requirements Additional Venting RequirementsChimney Inspection Chart Start-Up Procedures AdjustmentsExample 88,000 Btuh Input Furnace Installed AT 4300 FT See Venting Notes on Horizontal Left Application-Vent Elbow Right Then Up Horizontal Left Application-Vent Elbow LeftHorizontal Right Application-Vent Elbow PCB Altitude Derate Multipler for U.S.A Speed SelectionAltitude Percent Derate Multiplier Factor GAS Rate CU FT/HR Check Safety ControlsIntroduction ChecklistService and Maintenance Procedures Electrical Controls and WiringCare and Maintenance Service LabelFurnace Filter Quantity and Size Casing Width Cleaning AND/OR Replacing AIR FilterFilter Size Information Blower Motor and WheelPosition of Igniter to Burner Cleaning Heat ExchangerSequence of Operation Cleaning Heat Exchanger CellTroubleshooting Wiring DiagramsAltitude 700 6001 725 750 7000 775 800 825 850 725750 5001 775 800 6000 825 850 875 900 67510,000 9001875 900 925 950 900 925 950 975850 3000 875 900 Canada 925 775 800750 5001 775 800 6000 825 850 875 900 600 9001 625 650 10,000 675 700 725 Troubleshooting Guide Blocked vent switch used in Chimney Adapter Kit Copyright 2002 Carrier Corporation
Related manuals
Manual 52 pages 27.61 Kb

310JAV, 310AAV specifications

The Bryant 310AAV and 310JAV are high-efficiency air conditioning and heating systems designed for residential and light commercial applications. These models embody Bryant's commitment to delivering reliable comfort solutions while prioritizing energy efficiency and performance.

One of the standout features of the Bryant 310AAV and 310JAV is their impressive Seasonal Energy Efficiency Ratio (SEER) ratings. The higher the SEER, the more efficient the unit is in using electricity to cool your space. The Bryant 310AAV boasts a SEER rating of up to 16, while the 310JAV offers a slightly lower rating. This efficiency translates into cost savings on monthly energy bills while ensuring indoor comfort throughout the year.

Both models utilize advanced technologies, including two-stage heating and cooling capabilities. This means that the systems can adjust their operation based on the heating or cooling needs of a space, providing optimal temperature control while reducing energy waste. The two-stage operation also contributes to quieter operation levels, making these units suitable for residential settings where noise is a concern.

The 310AAV and 310JAV are equipped with variable-speed compressors, which further enhance their efficiency and comfort levels. The variable-speed technology allows the system to operate at different speeds, ensuring consistent temperature management and reducing the frequency of on-and-off cycling. This leads to steadier indoor temperatures and improved humidity control.

In addition to their performance features, Bryant places a strong emphasis on durability and dependability. The units are constructed with high-quality materials that are designed to withstand various environmental conditions. Features such as a weather-resistant cabinet and an efficient coil design help protect the units from wear and tear, ensuring long-lasting performance.

The implementation of environmentally friendly refrigerant options is another characteristic that demonstrates Bryant's commitment to sustainability. Both the 310AAV and 310JAV utilize R-410A refrigerant, which has a lower environmental impact compared to older refrigerants, aligning with modern standards for eco-friendly HVAC systems.

Overall, the Bryant 310AAV and 310JAV represent a blend of efficiency, advanced technology, and durability. With their attractive SEER ratings, two-stage operation, variable-speed capabilities, and commitment to sustainability, these models stand out as excellent choices for homeowners and businesses looking to enhance their heating and cooling solutions while keeping energy consumption in check. Whether for residential comfort or light commercial use, these Bryant units promise reliability and performance for years to come.