Empire Products GWT-25-2, GWT-35-2, RB) Thermostat Location SG Models, System Check Figure

Page 11

THERMOSTAT LOCATION (SG MODELS)

CAUTION — Do not run wire behind flanges of Header Plate or in any location where it might be damaged.

Millivolt wall thermostats are specially designed for use on self- generating systems. They should never be used on line or low voltage A.C. circuits.

Interior Wall — The thermostat should be installed on an inside wall away from the furnace but in the same room.

Note: Use 16 gauge wire to prevent excessive loss of milli- volts.

Proper operation depends on a good pilot flame. The flame must cover the top of the thermopile. Cleaning of the pilot orifice and burner may be required due to spiders.

System Check (Figure 7)

A millivolt meter is required to check the system. Millivolt readings should be:

Across the thermopile terminals, 400-450 millivolts with thermostat OFF.

Across the thermopile terminals, 150-250 millivolts with thermostat ON.

Across the thermostat wires at the valve, less than 30 millivolts with thermostat ON.

Across the thermostat wires at the thermostat, less than 5 millivolts with thermostat ON. (Dirty pilot or low pressure will reduce readings.)

Connect thermostat wires to gas valve as shown in Figure 7.

Figure 7

12425-7-0406

Page 11

Image 11
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsInsulated Vent Enclosure Recommended Vent ConfigurationOval all parts purchase locally Checking Manifold Pressure Installing a New Main Gas CockPressure Testing of the Gas Supply System GAS SupplyROUGH-IN Instructions ClearancesVentilation and Combustion AIR Location ALL ModelsPlastering Figure Installing Furnace FigureFinishing Instructions Outer Casing Figure Installing Control DoorSystem Check Figure Thermostat Location SG ModelsWhat to do if YOU Smell GAS Service technician or gas supplierLighting Instructions Proper Pilot Flame Vent Safety Shutoff SystemProper Main Burner Flame If Pilot Does Not Light By Any Means TroubleshootingMain Gas Valve Does Not Open When Thermostat Is Turned On Pilot Does Not LightHOW to Order Repair Parts Parts ListParts View GWT-25 RB, GWT-35 RB, GWT-50 RB Remote Bulb Control Installation InstructionsModels GWT-25 SG, RB, GWT-35 SG, RB, GWT-50 SG, RB Optional Blower Installation InstructionsGWTB-2 for Models GWTB-2 Wiring Diagram Service Notes

GWT-35-2, RB), GWT-25-2 specifications

Empire Products is renowned for its commitment to quality and innovation, particularly in the realm of heating solutions. Among their extensive range, the GWT-35-2 and GWT-25-2 gas-fired wall heaters stand out as exceptional choices for both residential and commercial applications.

The Empire GWT-35-2 is designed to deliver a powerful heating solution, boasting an impressive heat output. With an efficiency rating that ensures optimal warmth while minimizing energy consumption, this model is perfect for larger spaces that require consistent and reliable heating. Its sleek design allows it to seamlessly blend into various room aesthetics, while the multiple installation options make it versatile enough to meet varying layouts and preferences.

On the other hand, the GWT-25-2 is tailored for slightly smaller areas, yet it does not compromise on performance. This model provides ample heating efficiency and is well-suited for those looking to maintain a cozy atmosphere in modest-sized rooms. The unit’s compact form factor allows for easy installation without occupying too much wall space, making it an ideal option for residential settings.

Both models utilize advanced technologies that contribute to their superior performance. The state-of-the-art electronic ignition system in the GWT series ensures reliable startups, while the built-in thermostat provides precise temperature control. Users can easily adjust settings to their comfort levels, enhancing overall user satisfaction. Additionally, the heaters are equipped with innovative safety features such as automatic shut-off mechanisms, making them a safe choice for any environment.

Another key characteristic of the GWT-35-2 and GWT-25-2 is their fuel efficiency. By utilizing natural gas or propane, these units are designed to reduce energy costs without sacrificing heating quality. The durable construction of both models guarantees longevity and resilience, meaning customers can expect years of dependable service.

In summary, Empire Products' GWT-35-2 and GWT-25-2 wall heaters exemplify cutting-edge heating technology. Their combination of efficiency, performance, and safety features makes them a reliable choice for anyone in need of effective heating solutions, whether in a home or a commercial space. With Empire's commitment to quality, customers can feel confident in their investment in these powerful heating units.