Empire Products Empire GWT-25-2 Furnace Wiring Diagram and Fan Control Operation

Page 19

13” (330 mm)

4 7/16”

(112.6 mm)

Figure 3

Fan Control

The automatic fan control is located on the bottom of the blower assembly. The fan control is a nonadjustable, automatic type. The fan control will require between 3 and 7 minutes of main burner operation before the fan control "closes" and activates the blower. The blower will continue to run between 3 and 7 minutes after the main burner shuts off, before the fan control "opens" and deactivates the blower.

Wiring

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug foryourprotection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screws. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded.

WARNING:

Unplugging of blower accessory will not stop the heater from cycling. To shut heater off: Turn temperature dial or thermostat to lowest setting. Turn knob on gas control to "OFF", depressing slightly. Do not force.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Oiling

The blower motor does not have oiling holes. Do not attempt to oil the blower motor.

GWTB-2 WIRING DIAGRAM

 

 

 

PARTS LIST

 

 

 

 

INDEX

PART

 

NO.

NUMBER

DESCRIPTION

 

 

 

 

1

R-2204

CORD SET

2

8720161

STRAIN RELIEF BUSHING

3

15888

BLOWER HOUSING ASSEMBLY

4

8520142

BRASS BUSHING (4 REQUIRED)

5GWT-197 BLOWER SIDE (2 REQUIRED)

6

R-3085

WIRE ASSEMBLY

7

R-2503

FAN SWITCH

8

15887

BLOWER FRONT

9

8520141

RUBBER GROMMET (4 REQUIRED)

10

R-2804A

BLOWER MOTOR

12425-7-0406

Page 19

Image 19
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsOval all parts purchase locally Recommended Vent ConfigurationInsulated Vent Enclosure Checking Manifold Pressure Installing a New Main Gas CockPressure Testing of the Gas Supply System GAS SupplyROUGH-IN Instructions ClearancesVentilation and Combustion AIR Location ALL ModelsFinishing Instructions Installing Furnace FigurePlastering Figure Outer Casing Figure Installing Control DoorSystem Check Figure Thermostat Location SG ModelsLighting Instructions Service technician or gas supplierWhat to do if YOU Smell GAS Proper Main Burner Flame Vent Safety Shutoff SystemProper Pilot Flame If Pilot Does Not Light By Any Means TroubleshootingMain Gas Valve Does Not Open When Thermostat Is Turned On Pilot Does Not LightHOW to Order Repair Parts Parts ListParts View Models Remote Bulb Control Installation InstructionsGWT-25 RB, GWT-35 RB, GWT-50 RB GWTB-2 for Models Optional Blower Installation InstructionsGWT-25 SG, RB, GWT-35 SG, RB, GWT-50 SG, RB GWTB-2 Wiring Diagram Service Notes

GWT-35-2, RB), GWT-25-2 specifications

Empire Products is renowned for its commitment to quality and innovation, particularly in the realm of heating solutions. Among their extensive range, the GWT-35-2 and GWT-25-2 gas-fired wall heaters stand out as exceptional choices for both residential and commercial applications.

The Empire GWT-35-2 is designed to deliver a powerful heating solution, boasting an impressive heat output. With an efficiency rating that ensures optimal warmth while minimizing energy consumption, this model is perfect for larger spaces that require consistent and reliable heating. Its sleek design allows it to seamlessly blend into various room aesthetics, while the multiple installation options make it versatile enough to meet varying layouts and preferences.

On the other hand, the GWT-25-2 is tailored for slightly smaller areas, yet it does not compromise on performance. This model provides ample heating efficiency and is well-suited for those looking to maintain a cozy atmosphere in modest-sized rooms. The unit’s compact form factor allows for easy installation without occupying too much wall space, making it an ideal option for residential settings.

Both models utilize advanced technologies that contribute to their superior performance. The state-of-the-art electronic ignition system in the GWT series ensures reliable startups, while the built-in thermostat provides precise temperature control. Users can easily adjust settings to their comfort levels, enhancing overall user satisfaction. Additionally, the heaters are equipped with innovative safety features such as automatic shut-off mechanisms, making them a safe choice for any environment.

Another key characteristic of the GWT-35-2 and GWT-25-2 is their fuel efficiency. By utilizing natural gas or propane, these units are designed to reduce energy costs without sacrificing heating quality. The durable construction of both models guarantees longevity and resilience, meaning customers can expect years of dependable service.

In summary, Empire Products' GWT-35-2 and GWT-25-2 wall heaters exemplify cutting-edge heating technology. Their combination of efficiency, performance, and safety features makes them a reliable choice for anyone in need of effective heating solutions, whether in a home or a commercial space. With Empire's commitment to quality, customers can feel confident in their investment in these powerful heating units.