INTEGRATED CONTROL

(Automatic Hot Surface Ignition System)

HEAT BLOWER

DIAGNOSTIC CODE OFF DELAY JUMPER RECALL BUTTON

5AMP FUSE

 

TERMINAL DESIGNATIONS

 

HUM

Humidifier (120 VAC)

 

L1

Input (120 VAC)

 

XFMR

Transformer (120 VAC)

 

CONT

Blower - Continuous Fan (120 VAC)

 

EAC

Electronic Air Cleaner (120 VAC)

 

COOL

Blower - Cooling Speed (120 VAC)

 

HEAT

Blower - Heating Speed (120 VAC)

 

PARK

Dead terminals to park alternate spd taps

 

NEUTRALS Neutral terminals (120 VAC)

FIGURE 49

Unit Start-Up

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING

Do not use this furnace if any part has been underwater.

Aflood-damaged furnace is extremely dangerous. Attempts to use the furnace can result in fire or explosion. Immediately call a qualified service technician to inspect the furnace and to replace all gas controls, control system parts, and electrical parts that have been wet or to replace the furnace, if deemed necessary.

WARNING

Danger of explosion. Can cause injury or product or property damage. Should the gas supply fail to shut off or if overheating occurs, shut off the gas valve to the furnace before shutting off the electrical blower deck, before performing any service procedure.

CAUTION

Before attempting to perform any service or maintenance, turn the electrical power to unit OFF at disconnect switch.

BEFORE LIGHTING the unit, smell all around the furnace area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

The gas valve on the unit is equipped with a gas control switch (lever). Use only your hand to move switch. Never use tools. If the switch will not move by hand, do not try to repair it. Force or attempted repair may result in a fire or explosion.

Placing the furnace into operation:

This furnace is equipped with an automatic hot surface ignition system. Do not attempt to manually light burners on this furnace. Each time the thermostat calls for heat, the burners will automatically light. The ignitor does not get hot when there is no call for heat on these units.

Page 34 of 48

Issue 1109

506725-01

Image 34
Contents Table of Contents A95DF, A93DF, 95G1DF & 92G1DFTOP View Front View Side ViewParts Arrangement Shipping and Packing List Package 1 of 1 contains Safety InformationGas Furnace Building CodesLocations and Clearances Installed in Combination with a Cooling CoilUse of Furnace as Construction Heater Product Contains Fiberglass Wool Combustion, Dilution & Ventilation AirAir from Inside Unconfined SpaceConfined Space Equipment in Confined Space − ALL AIR from InsideAir from Outside Equipment in Confined Space − ALL AIR from OutsideShipping Bolt Removal Installation Setting EquipmentUnits with 1/2 HP Blower Motor Installation on Combustible Flooring Figure Installation on Non-Combustible Flooring FigureNON−COMBUSTIBLE Floor Opening Size Combustible Flooring Base Opening Size Installation on Cooling Coil Cabinet FigureReturn Air Opening Downflow Units Piping and Fittings Specifications Outdoor Termination Kits Usage Canadian Applications OnlyStandard Concentric Venting Practices Piping Suspension Guidelines Joint Cementing ProcedureReplacing Furnace That WAS Part of a Common Vent System MIN. Vent Length Exhaust Piping FigureMinimum Vent Pipe Lengths ModelsA95DF / 95G1DF and A93DF / 92G1DF Typical Exhaust Pipe Connections Typical Intake Pipe Connections Direct Vent ApplicationsTypical AIR Intake Pipe Connections For Canadian Installations OnlyIntake Piping General Guidelines for Vent TerminationsInside Corner Detail No minimum to outside corner Direct Vent Roof Termination KIT Exhaust Pipe Termination Size ReductionModel 51mm 76mm Direct Vent Concentric Rooftop Termination Direct Vent Application Using Existing ChimneyDirect Vent Concentric Wall Termination NON−DIRECT Vent Roof Termination KIT NON−DIRECT Vent Application Using Existing ChimneyNON−DIRECT Vent Field Supplied Wall Termination Extended NON−DIRECT Vent Field Supplied Wall TerminationCondensate Piping Unit with Evaporator CoilTrap / Drain Assembly Using 1/2 PVC or 3/4 PVC Leak Check Gas PipingFire or Explosion Hazard GAS Pipe Capacity − FT 3 /HR kL/HR Removal of the Furnace from Common Vent Carbon Monoxide Poisoning HazardElectrical Precautions and ProceduresAccessory Terminals Electrostatic Discharge ESDIndoor Blower Speeds Generator Use Voltage RequirementsTypical Wiring Diagram Unit Start-Up Integrated ControlAutomatic Hot Surface Ignition System Placing the furnace into operationTurning Off Gas to Unit Priming Condensate TrapGas Valve Operation Figure Failure To OperateGAS Meter Clocking Chart Burner Orifice Conversion Kits at Varying Altitudes Carbon Monoxide Poisoning Hazard Temperature Rise Flame Rollout Switches TwoPressure Switch Primary LimitBlower Data A93DF1D / 92G1DF Blower Data A95DF1D / 95G1DF Electrical SHOCK, Fire Or Explosion Hazard Cleaning the Burner Assembly Planned Service Diagnostic CodesControl Panel Parts Repair Parts ListCabinet Parts Heating Parts Blower PartsDuct System Supply AIR Duct GAS SupplyIntake / Exhaust Pipe Return DuctUnit Operation Clear of ALL Obstructions Manufacturer Requirements

A95DF, 95G1DF, A93DF, 92G1DF specifications

Allied Air Enterprises offers a range of high-efficiency commercial and residential heating and cooling systems, with models like the 92G1DF, A93DF, 95G1DF, and A95DF gaining popularity for their cutting-edge technology and advanced features. Each of these models stands out in performance, reliability, and energy efficiency, making them excellent choices for diverse applications.

The 92G1DF model features a multi-stage gas valve that enhances temperature regulation, allowing for more precise heating. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, this furnace efficiently utilizes fuel, resulting in lower energy costs and reduced emissions. Its compact design makes it suitable for installations in tight spaces, while the durable heat exchanger extends the unit’s lifespan.

In contrast, the A93DF is engineered for enhanced comfort and flexibility. This model incorporates a variable-speed blower motor, which adjusts air circulation according to the heating demands in the space. This feature not only maximizes comfort by providing consistent temperatures but also promotes energy savings by reducing unnecessary power consumption. Additionally, the A93DF includes advanced diagnostic capabilities that simplify troubleshooting and maintenance, making it a favorite among HVAC professionals.

The 95G1DF is another noteworthy model that combines versatile performance with exceptional efficiency. This furnace boasts an AFUE rating of up to 95%, making it one of the most efficient models in its class. Its innovative design includes a secondary heat exchanger that captures additional heat from exhaust gases, optimizing energy utilization. Furthermore, the 95G1DF is equipped with an advanced control system that allows homeowners to set specific comfort levels.

Lastly, the A95DF model takes efficiency to a new level. With features such as a modulating gas valve and a variable-speed blower, this unit seamlessly adapts to changing heating needs. The A95DF not only heats a space but also enhances air quality through advanced filtration options. Its whisper-quiet operation adds to user satisfaction, making it ideal for residential settings.

In summary, Allied Air Enterprises' models 92G1DF, A93DF, 95G1DF, and A95DF demonstrate a commitment to innovation and energy efficiency, with features designed to provide superior comfort and reliability. With their advanced technologies and high-performance characteristics, these models are positioned as top contenders in the heating and cooling marketplace, ensuring that customers can enjoy a comfortable environment year-round.