Allied Air Enterprises A95DF, 95G1DF dimensions Blower Data A93DF1D / 92G1DF

Page 40

BLOWER DATA A93DF1D / 92G1DF

A93DF1D / 92G1DF 045*12B PERFORMANCE (Less Filter)

External

Air Volume / Watts at Various Blower Speeds

Static

High

Medium-

Medium-

Low

Pressure

High

Low

 

 

in. w.g.

cfm Watts

cfm Watts

cfm Watts cfm Watts

 

0.001615 650 1385 555 1205 465 1045 390

0.101605 640 1375 545 1195 455 1035 380

0.201500 620 1340 525 1165 445 1015 370

0.301450 590 1290 490 1125 420 975 365

0.401350 560 1235 480 1090 405 920 345

0.501300 545 1170 450 1035 380 875 335

0.601195 500 1095 425 990 365 840 320

0.701140 485 1020 400 895 345 780 300

0.80

1025

450

920

370

840

330

695

275

0.90945 435 800 335 700 295 605 250

A93DF1D / 92G1DF 070*12B PERFORMANCE (Less Filter)

External

Air Volume / Watts at Various Blower Speeds

Static

High

Medium-

Medium-

Low

Pressure

High

Low

 

 

in. w.g.

cfm Watts

cfm Watts

cfm Watts cfm Watts

 

0.001505 660 1310 570 1090 455 940 390

0.101480 625 1295 550 1070 435 935 365

0.201405 585 1255 515 1055 425 930 350

0.301355 580 1225 475 1045 405 900 330

0.401305 540 1165 470 1010 385 890 325

0.50

1270

525

1110

425

975

370

835

305

0.601175 500 1080 415 925 345 815 290

0.701105 460 1000 395 855 320 745 270

0.80

1040

440

925

365

790

300

670

250

0.90

920

400

825

335

680

270

560

225

A93DF1D / 92G1DF 090*16C PERFORMANCE (Less Filter)

External

Air Volume / Watts at Various Blower Speeds

Static

High

Medium-

Medium-

Low

Pressure

High

Low

 

 

in. w.g.

cfm Watts

cfm Watts

cfm Watts cfm Watts

 

0.002145 900 1865 740 1545 635 1295 530

0.102135 890 1855 730 1540 625 1290 520

0.202065 845 1815 710 1525 600 1285 500

0.302010 825 1760 685 1510 580 1275 485

0.401930 775 1705 630 1495 575 1235 455

0.501845 740 1645 610 1450 530 1215 450

0.601745 700 1525 550 1380 505 1185 430

0.701620 650 1460 535 1315 480 1110 405

0.801450 585 1340 505 1220 445 1020 375

0.901320 555 1130 450 1010 385 920 345

A93DF1D / 92G1DF 110*20C PERFORMANCE (Less Filter)

External

Air Volume / Watts at Various Blower Speeds

Static

High

Medium-

Medium-

Low

Pressure

High

Low

 

 

in. w.g.

cfm Watts

cfm Watts

cfm Watts cfm Watts

 

0.002410 1390 2190 1080 1860 910 1560 735

0.102405 1385 2180 1070 1855 905 1555 730

0.202285 1345 2120 1030 1850 865 1540 720

0.302220 1315 2015 1005 1770 840 1535 705

0.402185 1295 1950 955 1750 815 1530 685

0.502045 1240 1830 925 1680 790 1500 660

0.601965 1220 1710 890 1575 755 1445 640

0.701820 1165 1610 850 1495 720 1370 615

0.801625 1155 1510 820 1400 695 1315 595

0.901455 1110 1390 790 1350 660 1210 565

NOTES: All air data is measured external to unit without filter (not furnished - field provided)

Page 40 of 48

Issue 1109

506725-01

Image 40
Contents Table of Contents A95DF, A93DF, 95G1DF & 92G1DFTOP View Front View Side ViewParts Arrangement Safety Information Gas FurnaceShipping and Packing List Package 1 of 1 contains Building CodesLocations and Clearances Installed in Combination with a Cooling CoilUse of Furnace as Construction Heater Product Contains Fiberglass Wool Combustion, Dilution & Ventilation AirUnconfined Space Confined SpaceAir from Inside Equipment in Confined Space − ALL AIR from InsideAir from Outside Equipment in Confined Space − ALL AIR from OutsideShipping Bolt Removal Installation Setting EquipmentUnits with 1/2 HP Blower Motor Installation on Combustible Flooring Figure Installation on Non-Combustible Flooring FigureNON−COMBUSTIBLE Floor Opening Size Combustible Flooring Base Opening Size Installation on Cooling Coil Cabinet FigureReturn Air Opening Downflow Units Piping and Fittings Specifications Outdoor Termination Kits Usage Canadian Applications OnlyStandard Concentric Venting Practices Piping Suspension Guidelines Joint Cementing ProcedureReplacing Furnace That WAS Part of a Common Vent System Exhaust Piping Figure Minimum Vent Pipe LengthsMIN. Vent Length ModelsA95DF / 95G1DF and A93DF / 92G1DF Typical Exhaust Pipe Connections Typical Intake Pipe Connections Direct Vent ApplicationsFor Canadian Installations Only Intake PipingTypical AIR Intake Pipe Connections General Guidelines for Vent TerminationsInside Corner Detail No minimum to outside corner Direct Vent Roof Termination KIT Exhaust Pipe Termination Size ReductionModel 51mm 76mm Direct Vent Concentric Rooftop Termination Direct Vent Application Using Existing ChimneyDirect Vent Concentric Wall Termination NON−DIRECT Vent Application Using Existing Chimney NON−DIRECT Vent Field Supplied Wall Termination ExtendedNON−DIRECT Vent Roof Termination KIT NON−DIRECT Vent Field Supplied Wall TerminationCondensate Piping Unit with Evaporator CoilTrap / Drain Assembly Using 1/2 PVC or 3/4 PVC Leak Check Gas PipingFire or Explosion Hazard GAS Pipe Capacity − FT 3 /HR kL/HR Removal of the Furnace from Common Vent Carbon Monoxide Poisoning HazardPrecautions and Procedures Accessory TerminalsElectrical Electrostatic Discharge ESDIndoor Blower Speeds Generator Use Voltage RequirementsTypical Wiring Diagram Integrated Control Automatic Hot Surface Ignition SystemUnit Start-Up Placing the furnace into operationPriming Condensate Trap Gas Valve Operation FigureTurning Off Gas to Unit Failure To OperateGAS Meter Clocking Chart Burner Orifice Conversion Kits at Varying Altitudes Carbon Monoxide Poisoning Hazard Flame Rollout Switches Two Pressure SwitchTemperature Rise Primary LimitBlower Data A93DF1D / 92G1DF Blower Data A95DF1D / 95G1DF Electrical SHOCK, Fire Or Explosion Hazard Cleaning the Burner Assembly Planned Service Diagnostic CodesRepair Parts List Cabinet Parts Heating PartsControl Panel Parts Blower PartsGAS Supply Intake / Exhaust PipeDuct System Supply AIR Duct Return DuctUnit Operation Clear of ALL Obstructions Manufacturer Requirements

A95DF, 95G1DF, A93DF, 92G1DF specifications

Allied Air Enterprises offers a range of high-efficiency commercial and residential heating and cooling systems, with models like the 92G1DF, A93DF, 95G1DF, and A95DF gaining popularity for their cutting-edge technology and advanced features. Each of these models stands out in performance, reliability, and energy efficiency, making them excellent choices for diverse applications.

The 92G1DF model features a multi-stage gas valve that enhances temperature regulation, allowing for more precise heating. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, this furnace efficiently utilizes fuel, resulting in lower energy costs and reduced emissions. Its compact design makes it suitable for installations in tight spaces, while the durable heat exchanger extends the unit’s lifespan.

In contrast, the A93DF is engineered for enhanced comfort and flexibility. This model incorporates a variable-speed blower motor, which adjusts air circulation according to the heating demands in the space. This feature not only maximizes comfort by providing consistent temperatures but also promotes energy savings by reducing unnecessary power consumption. Additionally, the A93DF includes advanced diagnostic capabilities that simplify troubleshooting and maintenance, making it a favorite among HVAC professionals.

The 95G1DF is another noteworthy model that combines versatile performance with exceptional efficiency. This furnace boasts an AFUE rating of up to 95%, making it one of the most efficient models in its class. Its innovative design includes a secondary heat exchanger that captures additional heat from exhaust gases, optimizing energy utilization. Furthermore, the 95G1DF is equipped with an advanced control system that allows homeowners to set specific comfort levels.

Lastly, the A95DF model takes efficiency to a new level. With features such as a modulating gas valve and a variable-speed blower, this unit seamlessly adapts to changing heating needs. The A95DF not only heats a space but also enhances air quality through advanced filtration options. Its whisper-quiet operation adds to user satisfaction, making it ideal for residential settings.

In summary, Allied Air Enterprises' models 92G1DF, A93DF, 95G1DF, and A95DF demonstrate a commitment to innovation and energy efficiency, with features designed to provide superior comfort and reliability. With their advanced technologies and high-performance characteristics, these models are positioned as top contenders in the heating and cooling marketplace, ensuring that customers can enjoy a comfortable environment year-round.