Superior NEC004-TD manual Retain These Instructions For Future Reference, OTL Report No -F-17-4

Page 1

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

OTL Report No. 116-F-17-4

WARNING:IFTHEINFORMATIONINTHISMANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO- SION MAY RESULT CAUSING PROPERTY DAM- AGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin- ity of this or any other appliance.

FOR YOUR SAFETY: What to do if you smell gas:

DO NOT light any appliance.

DO NOT touch any electrical switches.

DO NOT use any phone in your building.

Immediately call your gas supplier from a

neighbor’s phone.

Follow your gas suppliers instructions.

If your gas supplier cannot be reached, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

HOMEOWNER'S CARE AND OPERATION INSTRUCTIONS

DIRECT VENT

DT-400 AND DR-400

33" DIRECT-VENT GAS FIREPLACE HEATERS P/N 725,023M REV. J 11/2004

MODELS

Millivolt Electronic

Models Models

DT-400CMN DT-400CEN

DT-400CMP DT-400CEP

DR-400CMN DR-400CEN

DR-400CMP DR-400CEP

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LESINSTRUCTIONSDONNÉDANSCETTENOTICEPOUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.

POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser d'essence ni d'autre vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.

POUR VOTRE SÉCURITÉ: Que faire si vous sentez une odeur de gaz:

Ne pas tenter d'allumer d'appareil.

Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le batiment où vous vous trouvez.

Evacuez la piéce, le bâtiment ou la zone.

Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.

Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service dos incendies.

L'installation et service doit être exécuté par un qualifié installeur, agence de service ou le fournisseur de gaz.

Image 1
Contents OTL Report No -F-17-4 Retain These Instructions For Future ReferenceCongratulations Table of ContentsOperation and Care of Your Appliance GasControls/ControlCompartmentAccessMillivolt Appliances Electronic AppliancesMaintenance Glass CleaningVariable Flame Height Adjustment Millivolt Appliances only Ways of the appliance be kept cleanMaintenance Task Accomplishing Person Procedure Maintenance ScheduleBurner Adjustments Front Glass Enclosure Panel, Removal and InstallationReinstall the top louver or radiant panel AdjustmentGlowing Ember Placement Log PlacementModels DT-400 DR-400Electronic Electronic Appliance CheckoutReplacement Parts WarrantyAccessory Components Product Reference Information Decorative Volcanic StoneOptional on Unit Rocker Switch Standard Remote Control System Model RCLDeluxe Remote Control System Model RCL-T Screen Panel KitDecorative Log Rack Clean Face Panel KitsForced Air Kit Touch-Up Paint KitLighting Instructions Lighting Instructions Honeywell and SIT Millivolt GAS ValveTo Turn OFF GAS to Appliance What to do if YOU Smell GASPour Fermer LE GAZ QUI Alimente L’APPAREIL Instructions DallumageWhat to do if YOU Smell GAS Lighting Instructions ElectronicTo Shut OFF Instructions D’ALLUMAGE Instructions D’ALLUMAGE ElectronicPour Éteindre L’APPAREIL Pour Fermer LE GAZ QUI Alimente L’APPAREILSymptom Possible Causes Corrective Action Check vent system for obstructions Troubleshooting the Electronic Ignition SystemGAS Controls Honeywell Millivolt Replacement Parts ListNatural Description4237 Replacement Parts725,023M REV. J 11/2004 Orange, CA