Lennox Hearth MPD-45 Series SIT Gas Valve Honeywell Piezo Ignitor, Electronic Appliance Checkout

Page 24

24

Step 7. INSTALLINGLOGS,VERMICULITE, DECORATIVE VOLCANIC STONE AND GLOWING EMBERS

The packaged logs are located within the firebox. The vermiculite, decorative volcanic stone and glowing embers are packaged sepa- rately in plastic bags located in the control area of the fireplace. Refer to the Log Set Place- ment Guide for detailed placement instruc- tions for the logs, vermiculite, decorative vol- canic stone and glowing embers.

Step 8. CHECKING APPLIANCE OPERATION

With gas line installed run initial system check- out before closing up the front of the unit. Follow the pilot lighting instructions provided in the Care and Operation Instructions. For piezo ignitor location see Figure 49 (Honeywell millivolt appliances only).

Note: Lighting Instructions are also found on the literature tag attached to the gas valve train.

When first lighting the appliance, it will take a few minutes for the line to purge itself of air. Once purging is complete, the pilot and burner will light and operate as indicated in the in- struction manual. Subsequent lightings of the appliance will not require such purging. In- spect the pilot flame (remove logs, if neces- sary, handling carefully).

SIT Gas Valve

Honeywell

Gas Valve

Piezo

Ignitor

Sit and Honeywell Millivolt Gas Valve

Showing Piezo Ignitor Location (Each Unit is Equipped with Only One of these Gas Valves)

Figure 49

SIT and Honeywell Millivolt Appliance Checkout

The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top 3/8" (10 mm) at the pilot generator (thermopile) and the top 1/8" min (tip) of the quick drop out thermocouple should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports (Figure 50 - SIT, Figure 51 - Honeywell )

SIT MILLIVOLT

Hood Ignitor Rod

Thermocouple

3/8" Min (9 mm)

Pilot Nozzels

Thermopile

Figure 50

Replace logs if removed for pilot inspection.

To light the burner; turn “ON” the remote wall switch and rotate the gas valve control knob counterclockwise to the “ON” position.

MILLIVOLT HONEYWELL Thermocouple

1/8" Min

Ignitor Rod

Hood

(3 mm)

 

3/8" Min (9 mm)

Pilot

Nozzels

Thermopile

Figure 51

Electronic Appliance Checkout

To light the burner, turn ‘ON’ the optional remote wall switch and turn the gas control switch to the “ON” position. Ensure the ignitor lights the pilot. The pilot flame should engulf the flame rod as shown in Figure 52.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

ELECTRONIC

3/8 To 1/2 Inch

Proper Flame(9 mm to 13 mm) Adjustment

Pilot

Nozzle

Ground

Electrode

Flame Rod

Hot Surface

Igniter

Figure 52

Step 9. INSTALLING THE GLASS DOOR

Retrieve the glass door. Visually inspect the gasket on the backside of the frame. Gasket surface must be clean, free of irregularities and seated firmly. Position the door in front of the firebox opening with the bottom of the door held away from the fireplace (Figure 53 ). Hook the top flange of the door frame over the top of the firebox frame.

Let the bottom of the door frame swing gently in towards the fireplace ensuring that the gas- ket seats evenly as the door frame draws shut. Fasten the two latches located underneath the firebox floor to the door's vee-flange. Close both the latches securely.

 

Top Flange

 

Door Frame

 

Glass Door

Latch

 

Bottom Vee-flange

Latch

Door Frame

Firebox Floor

 

Figure 53 - INSTALLING THE GLASS DOOR

Image 24
Contents OTL Report No -F-13-4 MPD-3530CPE MPD4540CNE-BTable of Contents Input of millivolt models is shown in the following table Electronic ModelsAll Models Typical Locations LocationAppliance and Vent Clearances Other heating/air conditioning ductingTypical Installation Sequence Vent Termination ClearancesVertical Vent Termination Clearances Roof Pitch FeetDetailed Installation Steps FramingRouting GAS Line Canadian Installation US Installation Meter/regulator assembly= Clearance to service regulator vent outlet Feet 91cm Inches 30cm33 1/4 37 3/4 12 7/8 845 959 327 45 1/4 40 1/4 26 11/16 44 3/4Framing with Square Horizontal Termination SV4.5HT-2 Top View Front View Right Side ViewMassachusetts 33 1/8 30 1/8 27 1/2 19 5/8 21 1/2 10 3/4 13/16 11/32Installation of Vent Restrictor Vent Restrictor Installation Rear VentNew York City, NY Select Venting System Horizontal or VerticalVertical Straight Installation Vent Section Length ChartSV4.5FA or SV4.5SCVertical Offset Installation Vent / Appliance Collar ConnectionFraming Dimensions for Roof Pitch 12/1210-1/2 267 mm 305 mm 10-1/2 17-3/4 267 mm 451 mmVertical Vent FIGURES/TABLES Table aTable B FeetTable D Ceiling Firestop/Spacer Wall SV4.5VFSV4.5HF CeilingInstall firestop/spacer at ceiling Plan the vent runFrame exterior wall opening Support the vertical run sections See Section E onInstall the desired termination For the last step , from outside the exteriorInside the inner until the termination seats SV4.5RCHExterior Wall Thickness Inches mmTable F Table GHorizontal Vent FIGURES/TABLES Table HH1H Table K Table LCeiling Install the Outer Flex Pipe Install Firestop/Spacers at ceilings and wallsPull and extend the inner flexible vent pipe Pull and extend the outer flexible vent pipeField Wiring Wiring Optional Forced AIR Blower KITSIT and Honeywell Millivolt Wiring Electronic Wiring See orConnecting GAS Line Propane applicationsUse an open flame to check for leaks Installing the Glass Door SIT Gas Valve Honeywell Piezo IgnitorElectronic Appliance Checkout Checking Appliance OperationBurner Adjustments Flame Appearance and sooting Hood InstallationFinishing Requirements Wall DetailsCold Climate Insulation Mantel ClearancesInches mm TOPInstallation Accessories Cat.No. Model No. DescriptionCat.No Model No Description Support PlateCat Model Description Model DescriptionGAS Conversion Kits CanadaMillivolt Honeywell Systems KitsMillivolt SIT Systems Pilot for Honeywell Millivolt Gas Valve Shown on the tabArrows shown in Figure Orifice Strip Tab PositioningPilot Assembly Ignitor AssemblyFlare Nut Clip

MPD-35 Series, MPD-45 Series, MPD-33 Series, MPD-40 Series specifications

The Lennox Hearth MPD-33, MPD-40, MPD-45, and MPD-35 Series are sophisticated and innovative products designed for both aesthetic appeal and functional heating efficiency. These multi-sided gas fireplaces are engineered to bring warmth and style to any space, making them a popular choice for homeowners looking to enhance their living environment.

One of the standout features of the MPD Series is their versatile design. Each model is available in different sizes with stylish options, catering to various room dimensions and decor styles. The MPD-33, MPD-40, and MPD-45 models provide flexibility in installation, while the MPD-35 offers extra depth for a more pronounced fire presence, making them suitable for both contemporary and traditional interiors.

A key characteristic of the Lennox Hearth MPD Series is its high-efficiency operation. These fireplaces are designed to maximize heat output while minimizing fuel consumption, resulting in lower energy bills. The innovative burner system produces a realistic flame effect that can be adjusted to create the perfect ambiance for any occasion. The use of advanced technology ensures that the heat generated is evenly distributed, enhancing overall comfort.

Safety is paramount in the design of the MPD Series. Each model is equipped with a state-of-the-art safety shut-off system that activates if the flame goes out, ensuring peace of mind for users. Additionally, the glass front not only provides a clear view of the flames but is designed to stay cool to the touch, making it safe for families with children and pets.

The efficiency of these models is further complemented by an optional remote control feature, allowing users to adjust the flame height and thermostat settings with ease. The MPD Series is also compatible with smart home systems, providing users with added convenience.

Overall, the Lennox Hearth MPD-33, MPD-40, MPD-45, and MPD-35 Series exemplify the perfect combination of efficiency, safety, and design. Their ability to blend function with visual appeal makes them an ideal choice for creating a cozy atmosphere in any room, from living areas to bedrooms. These fireplaces stand as a testament to Lennox's commitment to quality and innovation in home heating solutions. With advanced technologies and a focus on user comfort, the MPD Series is designed to meet the needs of modern homeowners seeking reliable and stylish heating options.