Honeywell VISTA250BPT manual Event Log Procedures, Enter Code + # + 6 + Select the display mode

Page 57

Event Log Procedures

General Information

The system has the ability to record various events in a history log wherein each event is recorded in one of five categories (listed below), with the time and date of its occurrence. The Event Log holds up to 1000 events, with the oldest event being replaced by the logging of any new event after the log is full. Using an alpha keypad, the Event Log can be viewed one category at a time, or can display all events, regardless of category (ALL EVENT LOG). The system also allows selection of displaying the COMPLETE log, or only those events occurring since the last installer service (RECENT). In addition, events in the other partitions can be viewed by users authorized to access those partitions. Note that events are displayed in chronological order, from most recent to oldest.

To Display the Event Log

1.Enter CODE + # + [6] + [0]

2.Select the display mode.

RECENT: Displays only those events occurring since last Event Log Clear command was executed.

COMPLETE: Displays complete event log (up to 1000 events). Press the desired key, 0 or 1.

ENTER 0 = RECENT

1= COMPLETE

3.Select the partition, 0-8.

Enter the partition number for the partition whose events are to be displayed. Entering 0 (NO) will display all partitions' events.

SCAN LOG BY PART

0= NO 1-8 = PART#

4.Use the [3] & [1] keys (for next and previous categories respectively) to display the categories of events.

Press [8] to select a category and display the first event. Press [8] again for each subsequent event.

Shows burglary alarm occurred in zone 3 (C003) of partition 1 (P1), at 12:02AM on January 1.

P1 01/01 12:02AM BURGLARY C003

Typical

Event Log

Display

– 57 –

Image 57
Contents VISTA-128BPT VISTA-250BPT VISTA-128BPTSIA Page Table of Contents For Manually Activating Silent AND/OR Audible Alarms Viewing Alarm CompanyAccess Door Control Using #70 Relay Menu ModeGeneral System OverviewSystem Overview cont’d Burglary Protection Memory of AlarmDevice Timers Using SchedulesTo Access another Partition Goto Command Speed Key MacrosPhone Access & Voice Response Capability Self-Help FeatureAlpha Keypad About The KeypadsFunction Keys LCD Display Functions of the KeypadRemoves Individual Functions of the Keypad cont’dFunctions of the Keypad cont’d General Information Entry/Exit DelaysSecurity Codes and Authority Levels Installer Code LockoutDuress Code Quick ArmingSecurity Codes and Authority Levels cont’d Authority LevelsTo view your authority level and system capabilities General Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User To Access another Partition Accessing Other PartitionsGlobal Arming To Goto another partitionAccessing Other Partitions cont’d SystemStatus Fault 002 Loading Dock Window Whse Disarmed HIT ∗ for FaultsCommon Lobby Operation Codes with Global Arming How User Codes Affect the Common LobbyCodes with Non-Global Arming Other Methods of Arming/DisarmingTo show faulted zones Using Ready KeyTypical fault display Checking For Open ZonesDisplaying All Zone Descriptors Bypassing Protection Zones Using Bypass KeyTo bypass zones, the system must be disarmed first Bypass 007 Front Upstairs BedroomBypassing Protection Zones cont’d To use the Quick Bypass featureQuick Bypass Viewing Bypassed ZonesGroup Bypass To use the Group Bypass featureZones Remaining Bypassed After Disarming Using Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed Auto-STAY Arming With Entry Delay on cont’dArmed *INSTANT1 Zone Bypassed Using Instant KeyUsing the 2 Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using Maximum KeyUsing the # + 9 Keys Quick ExitTo Quick Exit the premises Disarming and Silencing Alarms Using the 1 OFF KeyTo disarm the system and silence burglary or fire alarms Arming Using the KeyswitchDisarming To arm in the Stay mode, turnUsing Key Chime ModeChime Mode on Chime Mode OFFMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysSpeed Key Macros DefiningEnter Speed KEY # Speed Key Macros cont’d ExecutingEnter User Code Access Door Control Enter Device no Using #70 Relay Menu ModeDelaying the Closing Time Using SchedulesClosing DELAY? KEY 0-2 Hours Temporary Open/Close SchedulesUsing Schedules cont’d Programming Temporary SchedulesTo program temporary schedules Days ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dRandomize Output Device Times Action Code Action Specifier Using #77 Instant Activation ModeBypass Commands Using #77 Instant Activation Mode cont’dAction ? Are YOU Sure ? To enter the Instant Activation ModeQuit Menu MODE? Zone List ?Enter Code + # + 6 + Select the display mode Event Log ProceduresEnter 0 = Recent = Complete Select the partitionAlarm Event LOG To Exit the Event Log Press ∗ at any timeType CCC UUU TIME/DATE THU Setting the Time and DateTesting Your System Using Test KeyFire Alarm System Case Of Fire AlarmSilencing a Fire Alarm Typical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureRecommendations for Smoke and Heat Detectors Recommendations for Proper ProtectionRecommendations for Proper Protection cont’d Recommendations for Proper Intrusion ProtectionAddition, we recommend the following Emergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Quick Guide to System Functions Function Procedure CommentsAM/PM Quick Guide to System Functions cont’dAlpha Display Keypads Summary of Audible NotificationIndustry Canada Class B Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Away IndexMaximum TWO Year Limited Warranty Page Ê800-06905EŠ

VISTA250BPT, 128BPTSIA, VISTA128BPT specifications

Honeywell's VISTA series of alarm control panels, including the VISTA250BPT, VISTA128BPT, and VISTA128BPTSIA, represents a robust solution for residential and commercial security needs. These panels combine advanced features, versatility, and cutting-edge technology to deliver reliable intrusion detection and alarm management capabilities.

The VISTA250BPT is designed for larger installations, supporting up to 250 zones. It features built-in Ethernet connectivity for remote access and control, enabling users to monitor their security systems from anywhere via a web browser or mobile app. This model is particularly suited for businesses requiring advanced integration with other systems, as it can handle multiple communication paths, including internet and phone lines.

On the other hand, the VISTA128BPT and VISTA128BPTSIA are ideal for medium-sized applications, supporting up to 128 zones. The VISTA128BPT includes an on-board transformer, while the VISTA128BPTSIA is tailored for installations needing SIA (Security Industry Association) compliance, making it suitable for a broader range of commercial environments. These models also offer flexible configuration options, allowing installers to customize the system to fit specific security requirements.

All models in the VISTA series utilize Honeywell's proprietary technology that enhances system reliability and responsiveness. They feature dual-path communication for enhanced system resilience, allowing for simultaneous data transmission over different networks. This ensures that even if one communication path fails, the other remains operational.

With user-friendly programming and management features, these panels can be easily configured through a keypad or remotely via a computer. Advanced event reporting capabilities provide detailed logs and notifications, ensuring users stay informed about their system's status. The integration of unique zone types, such as perimeter, interior, and 24-hour panic zones, allows for tailored security strategies.

Moreover, VISTA panels support various peripherals, including motion detectors, door/window sensors, and glass break detectors, providing comprehensive coverage for properties. The ability to integrate with home automation systems further enhances their functionality, making them a key component in smart home technology setups.

In summary, Honeywell's VISTA250BPT, VISTA128BPT, and VISTA128BPTSIA offer a blend of scalability, reliability, and advanced technological features, making them suitable for a wide range of security applications. Whether for a large business or a medium-sized property, these control panels provide security professionals and homeowners with the tools they need to safeguard their assets effectively.