Honeywell VISTA128BPT, VISTA250BPT, 128BPTSIA manual With Entry Delay on cont’d, Auto-STAY Arming

Page 34

Arming Perimeter Only

(With Entry Delay ON) (cont’d)

Auto-STAY Arming

Auto-stay allows the system to automatically bypass certain zones if upon arming none of the entry/exit zones are faulted during the exit delay time (no one exits the premises). The system provides an option to set each burglary zone for Auto-stay. All zones enabled for auto-stay except for perimeter and day/night types of zones, have exit delay time when the partition is armed.

Check with your installer for the zones assigned for Auto-STAY.

NOTES:

Auto-STAY applies to all four arming modes (AWAY, STAY, INSTANT and MAXIMUM).

Arming the partition AWAY via an RF transmitter overrides the Auto- stay feature (partition will not bypass zones programmed for auto-stay).

– 34 –

Image 34
Contents VISTA-128BPT VISTA-250BPT VISTA-128BPTSIA Page Table of Contents Access Door Control Viewing Alarm CompanyFor Manually Activating Silent AND/OR Audible Alarms Using #70 Relay Menu ModeSystem Overview GeneralSystem Overview cont’d Memory of Alarm Burglary ProtectionTo Access another Partition Goto Command Using SchedulesDevice Timers Speed Key MacrosSelf-Help Feature Phone Access & Voice Response CapabilityAbout The Keypads Alpha KeypadFunctions of the Keypad Function Keys LCD DisplayFunctions of the Keypad cont’d Removes IndividualFunctions of the Keypad cont’d Entry/Exit Delays General InformationDuress Code Installer Code LockoutSecurity Codes and Authority Levels Quick ArmingAuthority Levels Security Codes and Authority Levels cont’dTo view your authority level and system capabilities To Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User Global Arming Accessing Other PartitionsTo Access another Partition To Goto another partitionSystem Accessing Other Partitions cont’dStatus Whse Disarmed HIT ∗ for Faults Fault 002 Loading Dock WindowCommon Lobby Operation Codes with Non-Global Arming How User Codes Affect the Common LobbyCodes with Global Arming Other Methods of Arming/DisarmingTypical fault display Using Ready KeyTo show faulted zones Checking For Open ZonesDisplaying All Zone Descriptors To bypass zones, the system must be disarmed first Using Bypass KeyBypassing Protection Zones Bypass 007 Front Upstairs BedroomQuick Bypass To use the Quick Bypass featureBypassing Protection Zones cont’d Viewing Bypassed ZonesTo use the Group Bypass feature Group BypassZones Remaining Bypassed After Disarming Arming Perimeter Only Using Stay keyArmed ***STAY Zone Bypassed With Entry Delay on cont’d Auto-STAY ArmingUsing Instant Key Armed *INSTANT1 Zone BypassedArming All Protection Using the 2 Away KeyArmed **AWAY YOU MAY Exit NOW Using Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWQuick Exit Using the # + 9 KeysTo Quick Exit the premises Using the 1 OFF Key Disarming and Silencing AlarmsTo disarm the system and silence burglary or fire alarms Disarming Using the KeyswitchArming To arm in the Stay mode, turnChime Mode on Chime ModeUsing Key Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysDefining Speed Key MacrosEnter Speed KEY # Executing Speed Key Macros cont’dEnter User Code Access Door Control Using #70 Relay Menu Mode Enter Device noClosing DELAY? KEY 0-2 Hours Using SchedulesDelaying the Closing Time Temporary Open/Close SchedulesProgramming Temporary Schedules Using Schedules cont’dTo program temporary schedules Days ? Mtwtfss HIT 0-7 X To enter the device timer menu mode Programming Device TimersPorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Randomize Output Device Times Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsQuit Menu MODE? To enter the Instant Activation ModeAction ? Are YOU Sure ? Zone List ?Enter 0 = Recent = Complete Event Log ProceduresEnter Code + # + 6 + Select the display mode Select the partitionTo Exit the Event Log Press ∗ at any time Alarm Event LOGType CCC UUU Setting the Time and Date TIME/DATE THUUsing Test Key Testing Your SystemCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Trouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dRecommendations for Proper Protection Recommendations for Smoke and Heat DetectorsRecommendations for Proper Intrusion Protection Recommendations for Proper Protection cont’dAddition, we recommend the following Emergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Function Procedure Comments Quick Guide to System FunctionsQuick Guide to System Functions cont’d AM/PMSummary of Audible Notification Alpha Display KeypadsIndustry Canada Class B Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index AwayMaximum TWO Year Limited Warranty Page Ê800-06905EŠ

VISTA250BPT, 128BPTSIA, VISTA128BPT specifications

Honeywell's VISTA series of alarm control panels, including the VISTA250BPT, VISTA128BPT, and VISTA128BPTSIA, represents a robust solution for residential and commercial security needs. These panels combine advanced features, versatility, and cutting-edge technology to deliver reliable intrusion detection and alarm management capabilities.

The VISTA250BPT is designed for larger installations, supporting up to 250 zones. It features built-in Ethernet connectivity for remote access and control, enabling users to monitor their security systems from anywhere via a web browser or mobile app. This model is particularly suited for businesses requiring advanced integration with other systems, as it can handle multiple communication paths, including internet and phone lines.

On the other hand, the VISTA128BPT and VISTA128BPTSIA are ideal for medium-sized applications, supporting up to 128 zones. The VISTA128BPT includes an on-board transformer, while the VISTA128BPTSIA is tailored for installations needing SIA (Security Industry Association) compliance, making it suitable for a broader range of commercial environments. These models also offer flexible configuration options, allowing installers to customize the system to fit specific security requirements.

All models in the VISTA series utilize Honeywell's proprietary technology that enhances system reliability and responsiveness. They feature dual-path communication for enhanced system resilience, allowing for simultaneous data transmission over different networks. This ensures that even if one communication path fails, the other remains operational.

With user-friendly programming and management features, these panels can be easily configured through a keypad or remotely via a computer. Advanced event reporting capabilities provide detailed logs and notifications, ensuring users stay informed about their system's status. The integration of unique zone types, such as perimeter, interior, and 24-hour panic zones, allows for tailored security strategies.

Moreover, VISTA panels support various peripherals, including motion detectors, door/window sensors, and glass break detectors, providing comprehensive coverage for properties. The ability to integrate with home automation systems further enhances their functionality, making them a key component in smart home technology setups.

In summary, Honeywell's VISTA250BPT, VISTA128BPT, and VISTA128BPTSIA offer a blend of scalability, reliability, and advanced technological features, making them suitable for a wide range of security applications. Whether for a large business or a medium-sized property, these control panels provide security professionals and homeowners with the tools they need to safeguard their assets effectively.