Honeywell VISTA250BPT, VISTA128BPT Programming Device Timers, To enter the device timer menu mode

Page 51

Programming Device Timers

General Information

Device timers consist of an ON time & an OFF time, and selected days of the week in which they are active. There are up to 20 timers that can be used to control various devices, such as lights or appliances. Your installer will have programmed the appropriate devices into the system (up to 96 devices can be programmed).

Each timer controls a single device (designated as an output number) that you select. For example, timer 1 might be set to turn the porch lights on at 7:00pm and turn them off at 11:00pm. Timer 2 might turn on the air conditioner Monday-Friday at 4:30pm to cool the premises before you arrive at 5:00pm, and turn it off at 10:00pm when you are retiring for the night. If desired, different timers can control the same device. For example, timer 2 could be used Monday-Friday as in the previous example, and timer 3 could be set to turn the air conditioner on and off at different times Saturday and Sunday.

To enter the device timer menu mode:

Enter your security code, then press the

#

key followed by 83.

See your installer for device numbers.

OUTPUT TIMER # ? 01-20,00=QUIT 01

06 07:00P 11:45P

PORCH LITE 04

00 ENTER OUTPUT#

00

Up to 20 timers can be programmed. Each timer is identified by a number 1-20. Enter the desired timer number to be programmed (1-20). Press * to accept entry.

If that timer number has already been programmed, a summary screen will appear. In this example:

06 = Timer #

04 = Output Device # affected by this timer PORCH LITE = Output Descriptor for Device 4 07:00PM = Start Time;

11:45PM = Stop Time Press * to continue.

Enter the desired output device number (1-96). As the number is entered, the device's description will appear.

To delete a previously programmed timer, enter 00 as the output number.

– 51 –

Image 51
Contents VISTA-128BPT VISTA-250BPT VISTA-128BPTSIA Page Table of Contents Using #70 Relay Menu Mode Viewing Alarm CompanyFor Manually Activating Silent AND/OR Audible Alarms Access Door ControlGeneral System OverviewSystem Overview cont’d Burglary Protection Memory of AlarmSpeed Key Macros Using SchedulesDevice Timers To Access another Partition Goto CommandPhone Access & Voice Response Capability Self-Help FeatureAlpha Keypad About The KeypadsFunction Keys LCD Display Functions of the KeypadRemoves Individual Functions of the Keypad cont’dFunctions of the Keypad cont’d General Information Entry/Exit DelaysQuick Arming Installer Code LockoutSecurity Codes and Authority Levels Duress CodeSecurity Codes and Authority Levels cont’d Authority LevelsTo view your authority level and system capabilities General Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User To Goto another partition Accessing Other PartitionsTo Access another Partition Global ArmingAccessing Other Partitions cont’d SystemStatus Fault 002 Loading Dock Window Whse Disarmed HIT ∗ for FaultsCommon Lobby Operation Other Methods of Arming/Disarming How User Codes Affect the Common LobbyCodes with Global Arming Codes with Non-Global ArmingChecking For Open Zones Using Ready KeyTo show faulted zones Typical fault displayDisplaying All Zone Descriptors Bypass 007 Front Upstairs Bedroom Using Bypass KeyBypassing Protection Zones To bypass zones, the system must be disarmed firstViewing Bypassed Zones To use the Quick Bypass featureBypassing Protection Zones cont’d Quick BypassGroup Bypass To use the Group Bypass featureZones Remaining Bypassed After Disarming Using Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed Auto-STAY Arming With Entry Delay on cont’dArmed *INSTANT1 Zone Bypassed Using Instant KeyUsing the 2 Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using Maximum KeyUsing the # + 9 Keys Quick ExitTo Quick Exit the premises Disarming and Silencing Alarms Using the 1 OFF KeyTo disarm the system and silence burglary or fire alarms To arm in the Stay mode, turn Using the KeyswitchArming DisarmingChime Mode OFF Chime ModeUsing Key Chime Mode onMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysSpeed Key Macros DefiningEnter Speed KEY # Speed Key Macros cont’d ExecutingEnter User Code Access Door Control Enter Device no Using #70 Relay Menu ModeTemporary Open/Close Schedules Using SchedulesDelaying the Closing Time Closing DELAY? KEY 0-2 HoursUsing Schedules cont’d Programming Temporary SchedulesTo program temporary schedules Days ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dRandomize Output Device Times Action Code Action Specifier Using #77 Instant Activation ModeBypass Commands Using #77 Instant Activation Mode cont’dZone List ? To enter the Instant Activation ModeAction ? Are YOU Sure ? Quit Menu MODE?Select the partition Event Log ProceduresEnter Code + # + 6 + Select the display mode Enter 0 = Recent = CompleteAlarm Event LOG To Exit the Event Log Press ∗ at any timeType CCC UUU TIME/DATE THU Setting the Time and DateTesting Your System Using Test KeyFire Alarm System Case Of Fire AlarmSilencing a Fire Alarm Typical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureRecommendations for Smoke and Heat Detectors Recommendations for Proper ProtectionRecommendations for Proper Protection cont’d Recommendations for Proper Intrusion ProtectionAddition, we recommend the following Emergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Quick Guide to System Functions Function Procedure CommentsAM/PM Quick Guide to System Functions cont’dAlpha Display Keypads Summary of Audible NotificationIndustry Canada Class B Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Away IndexMaximum TWO Year Limited Warranty Page Ê800-06905EŠ

VISTA250BPT, 128BPTSIA, VISTA128BPT specifications

Honeywell's VISTA series of alarm control panels, including the VISTA250BPT, VISTA128BPT, and VISTA128BPTSIA, represents a robust solution for residential and commercial security needs. These panels combine advanced features, versatility, and cutting-edge technology to deliver reliable intrusion detection and alarm management capabilities.

The VISTA250BPT is designed for larger installations, supporting up to 250 zones. It features built-in Ethernet connectivity for remote access and control, enabling users to monitor their security systems from anywhere via a web browser or mobile app. This model is particularly suited for businesses requiring advanced integration with other systems, as it can handle multiple communication paths, including internet and phone lines.

On the other hand, the VISTA128BPT and VISTA128BPTSIA are ideal for medium-sized applications, supporting up to 128 zones. The VISTA128BPT includes an on-board transformer, while the VISTA128BPTSIA is tailored for installations needing SIA (Security Industry Association) compliance, making it suitable for a broader range of commercial environments. These models also offer flexible configuration options, allowing installers to customize the system to fit specific security requirements.

All models in the VISTA series utilize Honeywell's proprietary technology that enhances system reliability and responsiveness. They feature dual-path communication for enhanced system resilience, allowing for simultaneous data transmission over different networks. This ensures that even if one communication path fails, the other remains operational.

With user-friendly programming and management features, these panels can be easily configured through a keypad or remotely via a computer. Advanced event reporting capabilities provide detailed logs and notifications, ensuring users stay informed about their system's status. The integration of unique zone types, such as perimeter, interior, and 24-hour panic zones, allows for tailored security strategies.

Moreover, VISTA panels support various peripherals, including motion detectors, door/window sensors, and glass break detectors, providing comprehensive coverage for properties. The ability to integrate with home automation systems further enhances their functionality, making them a key component in smart home technology setups.

In summary, Honeywell's VISTA250BPT, VISTA128BPT, and VISTA128BPTSIA offer a blend of scalability, reliability, and advanced technological features, making them suitable for a wide range of security applications. Whether for a large business or a medium-sized property, these control panels provide security professionals and homeowners with the tools they need to safeguard their assets effectively.