Honeywell VISTA128BPT, VISTA250BPT Fire Alarm System, Case Of Fire Alarm, Silencing a Fire Alarm

Page 61

Fire Alarm System

Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency, the smoke and heat detectors automatically send signals to your Control, triggering a loud interrupting sound from the keypad and the optional exterior sounders. FIRE appears at your keypad and remains on until you silence the alarm.

NOTES:

All smoke detectors must be tested monthly by pressing the TEST button located on the detector. Be aware that your keypad(s) and local siren(s) will activate (enter your 4-digit code + [Off] to silence). If your system is monitored by a central station you must first call the central station to advise them that a test is in progress. If the TEST button does not cause the detector to activate it must be replaced immediately.

Ask your installer if your system is programmed for fire alarm verification, which can help reduce false alarms from smoke detectors.

In Case Of Fire Alarm

1.Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest keypad and manually initiate an alarm by pressing the panic key assigned as FIRE emergency (if programmed by the installer) and hold down for at least 2 seconds.

2.Evacuate all occupants from the premises.

3.If flames and/or smoke are present, leave the premises and notify your local Fire Department immediately.

4.If no flames or smoke are apparent, investigate the cause of the alarm. The descriptor of the zone(s) in alarm appears at the keypad.

Silencing a Fire Alarm

1.Silence the alarm by entering your code and pressing the OFF key. To clear the display, enter your code and press the OFF key again

2.If the keypad does not indicate a READY condition after the second OFF sequence, press the READY key to display the faulted zone(s). Be sure to check that smoke detectors are not responding to smoke or heat producing objects in their vicinity. Should this be the case, eliminate the source of heat or smoke.

3.If this does not remedy the problem, there may still be smoke in the detector. Clear it by fanning the detector for about 30 seconds.

4.You can clear the display by entering your code + the OFF key.

61 –

Image 61
Contents VISTA-128BPT VISTA-250BPT VISTA-128BPTSIA Page Table of Contents For Manually Activating Silent AND/OR Audible Alarms Viewing Alarm CompanyAccess Door Control Using #70 Relay Menu ModeGeneral System OverviewSystem Overview cont’d Burglary Protection Memory of AlarmDevice Timers Using SchedulesTo Access another Partition Goto Command Speed Key MacrosPhone Access & Voice Response Capability Self-Help FeatureAlpha Keypad About The KeypadsFunction Keys LCD Display Functions of the KeypadRemoves Individual Functions of the Keypad cont’dFunctions of the Keypad cont’d General Information Entry/Exit DelaysSecurity Codes and Authority Levels Installer Code LockoutDuress Code Quick ArmingAuthority Levels Security Codes and Authority Levels cont’dTo view your authority level and system capabilities General Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User To Access another Partition Accessing Other PartitionsGlobal Arming To Goto another partitionSystem Accessing Other Partitions cont’dStatus Fault 002 Loading Dock Window Whse Disarmed HIT ∗ for FaultsCommon Lobby Operation Codes with Global Arming How User Codes Affect the Common LobbyCodes with Non-Global Arming Other Methods of Arming/DisarmingTo show faulted zones Using Ready KeyTypical fault display Checking For Open ZonesDisplaying All Zone Descriptors Bypassing Protection Zones Using Bypass KeyTo bypass zones, the system must be disarmed first Bypass 007 Front Upstairs BedroomBypassing Protection Zones cont’d To use the Quick Bypass featureQuick Bypass Viewing Bypassed ZonesGroup Bypass To use the Group Bypass featureZones Remaining Bypassed After Disarming Arming Perimeter Only Using Stay keyArmed ***STAY Zone Bypassed Auto-STAY Arming With Entry Delay on cont’dArmed *INSTANT1 Zone Bypassed Using Instant KeyArming All Protection Using the 2 Away KeyArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using Maximum KeyQuick Exit Using the # + 9 KeysTo Quick Exit the premises Using the 1 OFF Key Disarming and Silencing AlarmsTo disarm the system and silence burglary or fire alarms Arming Using the KeyswitchDisarming To arm in the Stay mode, turnUsing Key Chime ModeChime Mode on Chime Mode OFFMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysDefining Speed Key MacrosEnter Speed KEY # Executing Speed Key Macros cont’dEnter User Code Access Door Control Enter Device no Using #70 Relay Menu ModeDelaying the Closing Time Using SchedulesClosing DELAY? KEY 0-2 Hours Temporary Open/Close SchedulesProgramming Temporary Schedules Using Schedules cont’dTo program temporary schedules Days ? Mtwtfss HIT 0-7 X To enter the device timer menu mode Programming Device TimersPorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dRandomize Output Device Times Action Code Action Specifier Using #77 Instant Activation ModeBypass Commands Using #77 Instant Activation Mode cont’dAction ? Are YOU Sure ? To enter the Instant Activation ModeQuit Menu MODE? Zone List ?Enter Code + # + 6 + Select the display mode Event Log ProceduresEnter 0 = Recent = Complete Select the partitionTo Exit the Event Log Press ∗ at any time Alarm Event LOGType CCC UUU TIME/DATE THU Setting the Time and DateTesting Your System Using Test KeyCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Typical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureRecommendations for Smoke and Heat Detectors Recommendations for Proper ProtectionRecommendations for Proper Intrusion Protection Recommendations for Proper Protection cont’dAddition, we recommend the following Emergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Quick Guide to System Functions Function Procedure CommentsAM/PM Quick Guide to System Functions cont’dAlpha Display Keypads Summary of Audible NotificationIndustry Canada Class B Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Away IndexMaximum TWO Year Limited Warranty Page Ê800-06905EŠ

VISTA250BPT, 128BPTSIA, VISTA128BPT specifications

Honeywell's VISTA series of alarm control panels, including the VISTA250BPT, VISTA128BPT, and VISTA128BPTSIA, represents a robust solution for residential and commercial security needs. These panels combine advanced features, versatility, and cutting-edge technology to deliver reliable intrusion detection and alarm management capabilities.

The VISTA250BPT is designed for larger installations, supporting up to 250 zones. It features built-in Ethernet connectivity for remote access and control, enabling users to monitor their security systems from anywhere via a web browser or mobile app. This model is particularly suited for businesses requiring advanced integration with other systems, as it can handle multiple communication paths, including internet and phone lines.

On the other hand, the VISTA128BPT and VISTA128BPTSIA are ideal for medium-sized applications, supporting up to 128 zones. The VISTA128BPT includes an on-board transformer, while the VISTA128BPTSIA is tailored for installations needing SIA (Security Industry Association) compliance, making it suitable for a broader range of commercial environments. These models also offer flexible configuration options, allowing installers to customize the system to fit specific security requirements.

All models in the VISTA series utilize Honeywell's proprietary technology that enhances system reliability and responsiveness. They feature dual-path communication for enhanced system resilience, allowing for simultaneous data transmission over different networks. This ensures that even if one communication path fails, the other remains operational.

With user-friendly programming and management features, these panels can be easily configured through a keypad or remotely via a computer. Advanced event reporting capabilities provide detailed logs and notifications, ensuring users stay informed about their system's status. The integration of unique zone types, such as perimeter, interior, and 24-hour panic zones, allows for tailored security strategies.

Moreover, VISTA panels support various peripherals, including motion detectors, door/window sensors, and glass break detectors, providing comprehensive coverage for properties. The ability to integrate with home automation systems further enhances their functionality, making them a key component in smart home technology setups.

In summary, Honeywell's VISTA250BPT, VISTA128BPT, and VISTA128BPTSIA offer a blend of scalability, reliability, and advanced technological features, making them suitable for a wide range of security applications. Whether for a large business or a medium-sized property, these control panels provide security professionals and homeowners with the tools they need to safeguard their assets effectively.