Honeywell VISTA128BPT, VISTA250BPT, 128BPTSIA manual Using Panic Keys

Page 43

Panic Keys

(For Manually Activating Silent and/Or Audible Alarms)

Using Panic Keys

Your system may have been programmed to use special key combinations to manually activate panic functions. The functions that might be programmed are Silent Emergency, Audible Emergency, Personal Emergency, and Fire. See your installer for the function(s) that may have been programmed for your system.

Active Panic Functions

(Your installer should note which function(s) is active in your system.)

Keys

Zone

Function

 

 

 

1 and *

995

 

 

 

 

3 and #

996

 

 

 

 

* and #

999

 

 

 

 

A

995

 

 

 

 

B

999

 

C

996

 

To use a paired key panic function, simply press both keys of the assigned pair at the same time.

If your keypad(s) have lettered keys for panic functions, press the designated key and hold down for at least 2 seconds to activate the panic function.

SIA Installations: Lettered keys not for use in CP-01 installations.

A silent emergency sends a silent alarm signal to the central station, but there will be no audible alarms or visual displays.

An audible emergency sends an emergency message to the central station (if connected) and will sound a loud, steady alarm at your keypad and at any external sounders that may be connected (ALARM plus a zone number would also be displayed).

A personal emergency alarm sends an emergency message to the central station (if connected) and will sound at Keypads, but not at external bells or sirens. (ALARM plus a zone number would also be displayed.)

A fire alarm sends a fire alarm message to the central station and will uniquely sound external bells and sirens (FIRE plus a zone number would also be displayed).

– 43 –

Image 43
Contents VISTA-128BPT VISTA-250BPT VISTA-128BPTSIA Page Table of Contents Using #70 Relay Menu Mode Viewing Alarm CompanyFor Manually Activating Silent AND/OR Audible Alarms Access Door ControlGeneral System OverviewSystem Overview cont’d Burglary Protection Memory of AlarmSpeed Key Macros Using SchedulesDevice Timers To Access another Partition Goto CommandPhone Access & Voice Response Capability Self-Help FeatureAlpha Keypad About The KeypadsFunction Keys LCD Display Functions of the KeypadRemoves Individual Functions of the Keypad cont’dFunctions of the Keypad cont’d General Information Entry/Exit DelaysQuick Arming Installer Code LockoutSecurity Codes and Authority Levels Duress CodeAuthority Levels Security Codes and Authority Levels cont’dTo view your authority level and system capabilities General Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Change a Users Code To Delete a User To Goto another partition Accessing Other PartitionsTo Access another Partition Global ArmingSystem Accessing Other Partitions cont’dStatus Fault 002 Loading Dock Window Whse Disarmed HIT ∗ for FaultsCommon Lobby Operation Other Methods of Arming/Disarming How User Codes Affect the Common LobbyCodes with Global Arming Codes with Non-Global ArmingChecking For Open Zones Using Ready KeyTo show faulted zones Typical fault displayDisplaying All Zone Descriptors Bypass 007 Front Upstairs Bedroom Using Bypass KeyBypassing Protection Zones To bypass zones, the system must be disarmed firstViewing Bypassed Zones To use the Quick Bypass featureBypassing Protection Zones cont’d Quick BypassGroup Bypass To use the Group Bypass featureZones Remaining Bypassed After Disarming Arming Perimeter Only Using Stay keyArmed ***STAY Zone Bypassed Auto-STAY Arming With Entry Delay on cont’dArmed *INSTANT1 Zone Bypassed Using Instant KeyArming All Protection Using the 2 Away KeyArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using Maximum KeyQuick Exit Using the # + 9 KeysTo Quick Exit the premises Using the 1 OFF Key Disarming and Silencing AlarmsTo disarm the system and silence burglary or fire alarms To arm in the Stay mode, turn Using the KeyswitchArming DisarmingChime Mode OFF Chime ModeUsing Key Chime Mode onMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysDefining Speed Key MacrosEnter Speed KEY # Executing Speed Key Macros cont’dEnter User Code Access Door Control Enter Device no Using #70 Relay Menu ModeTemporary Open/Close Schedules Using SchedulesDelaying the Closing Time Closing DELAY? KEY 0-2 HoursProgramming Temporary Schedules Using Schedules cont’dTo program temporary schedules Days ? Mtwtfss HIT 0-7 X To enter the device timer menu mode Programming Device TimersPorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dRandomize Output Device Times Action Code Action Specifier Using #77 Instant Activation ModeBypass Commands Using #77 Instant Activation Mode cont’dZone List ? To enter the Instant Activation ModeAction ? Are YOU Sure ? Quit Menu MODE?Select the partition Event Log ProceduresEnter Code + # + 6 + Select the display mode Enter 0 = Recent = CompleteTo Exit the Event Log Press ∗ at any time Alarm Event LOGType CCC UUU TIME/DATE THU Setting the Time and DateTesting Your System Using Test KeyCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Typical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureRecommendations for Smoke and Heat Detectors Recommendations for Proper ProtectionRecommendations for Proper Intrusion Protection Recommendations for Proper Protection cont’dAddition, we recommend the following Emergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Quick Guide to System Functions Function Procedure CommentsAM/PM Quick Guide to System Functions cont’dAlpha Display Keypads Summary of Audible NotificationIndustry Canada Class B Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Away IndexMaximum TWO Year Limited Warranty Page Ê800-06905EŠ

VISTA250BPT, 128BPTSIA, VISTA128BPT specifications

Honeywell's VISTA series of alarm control panels, including the VISTA250BPT, VISTA128BPT, and VISTA128BPTSIA, represents a robust solution for residential and commercial security needs. These panels combine advanced features, versatility, and cutting-edge technology to deliver reliable intrusion detection and alarm management capabilities.

The VISTA250BPT is designed for larger installations, supporting up to 250 zones. It features built-in Ethernet connectivity for remote access and control, enabling users to monitor their security systems from anywhere via a web browser or mobile app. This model is particularly suited for businesses requiring advanced integration with other systems, as it can handle multiple communication paths, including internet and phone lines.

On the other hand, the VISTA128BPT and VISTA128BPTSIA are ideal for medium-sized applications, supporting up to 128 zones. The VISTA128BPT includes an on-board transformer, while the VISTA128BPTSIA is tailored for installations needing SIA (Security Industry Association) compliance, making it suitable for a broader range of commercial environments. These models also offer flexible configuration options, allowing installers to customize the system to fit specific security requirements.

All models in the VISTA series utilize Honeywell's proprietary technology that enhances system reliability and responsiveness. They feature dual-path communication for enhanced system resilience, allowing for simultaneous data transmission over different networks. This ensures that even if one communication path fails, the other remains operational.

With user-friendly programming and management features, these panels can be easily configured through a keypad or remotely via a computer. Advanced event reporting capabilities provide detailed logs and notifications, ensuring users stay informed about their system's status. The integration of unique zone types, such as perimeter, interior, and 24-hour panic zones, allows for tailored security strategies.

Moreover, VISTA panels support various peripherals, including motion detectors, door/window sensors, and glass break detectors, providing comprehensive coverage for properties. The ability to integrate with home automation systems further enhances their functionality, making them a key component in smart home technology setups.

In summary, Honeywell's VISTA250BPT, VISTA128BPT, and VISTA128BPTSIA offer a blend of scalability, reliability, and advanced technological features, making them suitable for a wide range of security applications. Whether for a large business or a medium-sized property, these control panels provide security professionals and homeowners with the tools they need to safeguard their assets effectively.