Honeywell 800-04410, NetAXS manual Configure the Time Zones

Page 20

Configuring via the Web Server

Configuring the System

2.1 Overview

This chapter explains the NetAXS™ configuration functions as accessed via the NetAXS™ web server. These functions should be performed only by the NetAXS™ system administrator or service personnel.

Caution: The sequence of NetAXS™ configuration tasks is critical. If the sequence given below is not followed, the NetAXS™ system cannot be successfully configured.

The flow chart in Figure 2-1shows the order in which to perform the administrative functions.

Figure 2-1:NetAXS™ System Configuration Flow Chart

Configure the Panel

Configuration > System > Host/Loop Communications (Host/Loop

Communications Tab, page 11)

Configuration > System > Network (Network Tab, page 20)

Configuration > System > General (General Tab, page 14)

Configuration > System > Site Codes (Site Codes Tab, page 21)

Configure the Time Zones

Configuration > Time Management > Time Zones (Time Zones Tab, page 26)

Configure the Doors

Configuration > Doors > Reader (Reader Tab, page 31)

Configuration > Doors > Output (Outputs Tab, page 38)

Configuration > Doors > Inputs (Inputs Tab, page 42)

Configure the Access Levels

Configuration > Access Levels (Configuring Access Levels, page 45)

Create the Cards

Cards > Add Cards (Adding New Cards, page 47)

Assign Access Levels to Cards

Cards > Add Cards (Adding New Cards, page 47)

10www.honeywell.com

Image 20
Contents NetAXS Copyright 2009 Honeywell. All rights reserved Contents Configuring via WIN-PAK Monitoring NetAXS StatusUpgrading NetAXS Firmware IndexList of Figures Status Outputs Doors/Aux/Other/DnStr Tab List of Tables Page Dynamic Screens and Performance Enhancements Multi-language SupportCSV Reports and Card Upgrade Reverse IPConnecting to the Web Server OverviewConnecting to the Web Server NetAXS Web Server Hub ConnectionNetAXS Web Server Direct Connection Connecting to the Web Server Connecting to the Web Server Connecting to the Web Server Reading the Select Panel 1Reading the Select Panel1Reading the Select Panel Configuring via the Web Server Configure the Time Zones Configuring the System 2Configuration System Host/Loop Communications TabHost/Loop Communications tab enables you to Host/Loop Setting DescriptionHost/Loop Setting Description General Tab enables you to 2Configuration System General Tab Fields2Configuration System General Tab Fields Cards , 4Configuration System File Management Tab File Management tab enables you toSteps to reset the firmware version Steps to delete language files 5Configuration System Network Tab Network tab enables you to6Configuration System Site Codes Tab Site Codes tab enables you toSteps to delete a site code 7Configuration System Downstream Devices Tab Downstream Devices tab enables you toCurrent Time Tab Configuring Time ManagementCurrent Time tab enables you to 3Configuration Time Management Tab Field Descriptions Setting DescriptionTime Zones tab enables you to Time Zones TabLinking Time Zones Configuring via the Web Server Holidays tab enables you to Holidays TabSteps to create a holiday Reader Tab Configuring the DoorsReader tab enables you to Configuring via the Web Server 4Configuration Doors Reader Tab Descriptions Configuration System General screen see General Tab 12Configuration Doors Reader Card Formats Tab 5Configuration Doors Reader Card Format FieldsCID a 5Configuration Doors Reader Card Format Fields 13Discrete Lock Output Configuration Outputs Tab14Configuration Doors Outputs Group Tab Lock Outputs tab enables you to 6Configuration Doors Output Tab Field Descriptions 15Configuration Doors Inputs Tab Inputs TabInputs tab enables you to 7Configuration Doors Inputs Tab Field Descriptions Configuring Access Levels Access Levels screen enables you toSteps to create an access level Adding New Cards Add New Cards screen enables you toMaintaining Cards 8Cards Add Cards Field Descriptions Field DescriptionDisplay or Modify Cards screen enables you to Displaying and Modifying CardsDelete Cards screen enables you to Deleting Cards9Cards Reports Field Descriptions Card Reports screen enables you toDisplaying Reports Configuring Other I/O & Groups Tab 20Configuration Other I/O & Groups Inputs Tab Input tab enables you toSetting Description 21Configuration Other I/O & Groups Outputs Tab Configuration Other I/O & Groups Outputs Tab Fields Groups tab enables you to Groups TabSetting Description Configuring Interlocks Interlocks screen enables you to13Configuration Interlocks Field Descriptions Interlock element DescriptionConfiguring Users 24Configuration Users User Configuration screen enables you toSteps to modify a user Configuring via the Web Server Configuring the System Configuring via WIN-PAK Adding a New NetAXS Panel Creating the Panel with Quick Start WizardConfiguring the Panel Manually 2WIN-PAK Panel Configuration Screen Basic Tab3WIN-PAK Panel Configuration Screen Card Format Tab 4WIN-PAK Panel Configuration Screen Time Zones Tab 5WIN-PAK Panel Configuration Screen Options Tab Configuring via WIN-PAK 1Interlock Reassignments for NetAXS Interlock Function1Interlock Reassignments for NetAXS Configuring via WIN-PAK Monitoring NetAXS Status Monitoring Alarms 1Status Alarms Unacknowledged Tab2Status Alarms Acknowledged Tab 1Status Alarms Field DescriptionsOn the NetAXS board Monitoring Events 3Status Events Panel Tab2Status Events Panel Tab Field Descriptions 4Status Events Web Tab Input Status screen enables you to Monitoring InputsSteps Monitoring NetAXS Status Monitoring Outputs 6Status Outputs Doors/Aux/Other/DnStr TabOutput Status tab enables you to 7Status Outputs Groups TabSystem Status screen enables you to Monitoring System StatusMonitoring NetAXS Status Mixed Revision Loops NetAXS Release 3.1.8 Upgrade ProcedurePlanning the Upgrade Upgrades to Gateway vs. Multi-drop Panels Uploading Data from the PanelSelect the Configuration System File Management tab Upgrade Notes To clear the cache using Internet Explorer 7 IE7 Upgrading NetAXS Firmware Index Index Index-3 Index

NetAXS, 800-04410 specifications

The Honeywell 800-04410 NetAXS is a state-of-the-art access control system designed to enhance security and streamline management in commercial and industrial environments. This system is part of Honeywell's expanding portfolio of integrated security solutions, providing users with advanced technologies, straightforward management capabilities, and robust features suitable for various applications.

One of the main features of the Honeywell 800-04410 is its web-based access control management system. This allows users to control access permissions remotely via any internet-connected device. The intuitive user interface simplifies the process of managing user access levels, scheduling, and monitoring entry points without the need for specialized IT knowledge. The NetAXS enables centralized control for multiple locations, making it ideal for businesses with multiple sites or branches.

The NetAXS is built with advanced security protocols to protect sensitive data. End-to-end encryption ensures that communication between devices and the server is secure, reducing the risk of unauthorized access. In addition, it supports various authentication methods, including card readers, keypads, and biometric systems, providing flexibility in how organizations manage access.

Another noteworthy characteristic of the Honeywell 800-04410 is its scalability. The system can easily expand to accommodate additional doors, users, and locations without the need for significant infrastructure changes. This flexibility allows businesses to grow and adapt their security measures as required. The NetAXS technology is compatible with existing security systems, enhancing the value of previous investments in security infrastructure.

The installation of the Honeywell NetAXS is streamlined through its plug-and-play design, minimizing downtime during setup. Additionally, the system features an onboard memory that can store up to 100,000 access events, ensuring that no data is lost even during network outages.

The Honeywell 800-04410 is also designed with energy efficiency in mind. The system incorporates power management features that reduce energy consumption while maintaining optimal performance, reflecting Honeywell's commitment to sustainability.

In summary, the Honeywell 800-04410 NetAXS access control system offers a comprehensive solution for security management. With its web-based interface, advanced security features, scalability, easy installation, and energy efficiency, it stands out as a reliable choice for organizations seeking to enhance their security protocols and manage access effectively. Its integration capabilities, user-friendly design, and adaptability make the NetAXS an essential tool for modern access control needs.