White Rodgers 11B18 installation instructions Extending Capillary, Installation, Wiring

Page 2

CONVERTIBLE CONTROLS CONT.

NOTE

To convert from Vertical to Horizontal model, remove Knockout Plug and Plate. Remove Hex Nut (inside con- trol) and swing capillary upward into back knockout. Place Knockout Plate beneath Hex Nut on back of control and tighten Hex Nut (inside control). If bottom knockout is not used for wiring, insert Knockout Plug.

HEX NUT

 

MOUNTING STEM

KNOCKOUT PLUG

 

CAPILLARY

KNOCKOUT PLATE

 

BULB

 

Convertible Control converted to Vertical Model.

EXTENDING CAPILLARY

Some controls have excess stored capillary which may be extended for use with an extended shank well. Use reason- able care when straightening and forming the capillary.

With the capillary fully extended, the bulb should slide all the way to the end of the well.

INSTALLATION

If the boiler manufacturer recommends a control location, follow such recommendations. If none is offered, the following information gives suggested locations.

When used for high limit service, the control should be installed in the riser close to the boiler, or in a boiler tapping that is near the top or hottest section of the boiler. If the boiler is also used to heat domestic hot water, make sure that the high limit control is not located in the section of the boiler that contains the heat exchanger or piping for domestic hot water.

When used for low limit or operator service, the control should be located near that section of the boiler that

contains the heat exchanger or piping for domestic hot water.

To remove the well from the control, loosen the set screw in the large nut, then slide the well off to expose the bulb. Screw the well into the proper tapping. Slide the bulb back into the well, making sure that the bulb enters the well as far as it will go and tighten the set screw.

CAUTION

Do not dent or bend the bulb as this will prevent it from fitting into the well properly.

WIRING

All wiring should be done in accordance with local and national electrical codes and ordinances.

If the boiler or burner manufacturer recommends a wiring diagram, then follow such recommendations.

If none is offered, these diagrams show suggested cir- cuits.

HIGH

LIMIT

 

LINE

 

 

THERMOSTAT

 

 

 

INTERMITTENT IGNITION

 

GND

HOT

 

 

 

OIL BURNER CONTROL

 

 

 

 

 

 

FUSED

 

LIMIT

 

 

 

LINE

 

 

STACK

 

 

CONTROL

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

T T 1 2

3 4

Used as high limit

TRANS

 

 

 

 

 

control with

 

MOTOR

 

 

 

 

 

 

oil burner control

 

 

 

 

 

 

DIAPHRAGM

 

 

 

 

 

GAS VALVE

 

 

 

THERM PILOT TRANS

Used as high limit

 

control with

 

 

 

 

 

 

THERMOSTAT

Used as high limit control with Silent Knight gas valve with plug-in pilot

THERMOSTAT

diaphragm gas valve

SILENT KNIGHT

GAS VALVE

2

AUX

TRANSFORMER

 

 

3

TO

 

 

TH

TR

 

 

LINE

 

 

1

4

 

 

 

 

 

 

 

COIL

LIMIT

AUTOMATIC

 

 

 

CONTROL

 

 

PLUG-IN

 

PILOT

 

 

 

 

PILOT

2

 

TRANSFORMER

TO

LINE

IF AUTOMATIC PILOT IS NOT USED, CONNECT A JUMPER BETWEEN THE PILOT TERMINALS

Image 2
Contents Operator Save these instructions for future use PrecautionsHOT Water Control DescriptionExtending Capillary InstallationWiring Controls with Adjustable Stops Setting the ControlControls with Adjustable Differential Controls with a Fixed DifferentialPrécautions Commande D’EAU ChaudeCommandes Convertibles Pièce No 37-2068BCâblage Commandes Convertibles suiteExtension DU Capillaire Commandes À Différentiel Fixe Réglage DE LA CommandeCommandes À Différentiel Réglable Commandes À Butées Réglables

11B18 specifications

The White Rodgers 11B18 is an advanced thermostat designed for residential heating and cooling systems, known for its reliability, user-friendly interface, and energy efficiency. It's a part of the White Rodgers brand, a subsidiary of Emerson Electric, which has a longstanding reputation in the HVAC industry.

One of the main features of the 11B18 is its digital display, which provides clear visibility of the current temperature settings and allows users to easily navigate through different options. The backlit screen is especially useful during low-light conditions, enhancing usability during the night.

The 11B18 is equipped with a programmable function that allows users to set specific temperature schedules throughout the day. This feature promotes energy savings by allowing homeowners to adjust temperatures based on their daily routines, ensuring that heating and cooling are optimized when needed most. The programmable settings can typically accommodate up to four different temperature changes throughout a single day, enabling customized comfort.

In addition to its programmability, the 11B18 features advanced temperature sensing technology. This ensures that the thermostat accurately measures the ambient temperature, improving overall comfort and efficiency. With a built-in anticipatory feature, the thermostat can also predict when to start heating or cooling, ensuring the set temperature is reached by the desired time.

The compatibility of the White Rodgers 11B18 with various heating and cooling systems is another significant advantage. It can be used with single-stage and multi-stage HVAC systems, making it versatile for many households. This adaptability prevents the need for homeowners to invest in a new system when upgrading their thermostat.

Another characteristic of the 11B18 is its simplicity in installation and operation. Most users can install the thermostat themselves, thanks to the straightforward instructions and standard wiring requirements. Moreover, the intuitive user interface is designed so that even those who are not tech-savvy can set their preferences without difficulty.

Energy-saving features are paramount in modern thermostats, and the White Rodgers 11B18 does not disappoint. It includes an energy-saving mode that helps reduce utility bills by implementing energy-efficient systems. Overall, the White Rodgers 11B18 integrates performance, functionality, and convenience, making it a reliable choice for homeowners seeking an effective thermostat solution.