2.1Introduction to Installers

Before installing this KERR TW2000 Wood-Fired Boiler, please read the following instruction manual carefully. This unit is designed to be a freestanding central heating boiler, or as an add-on to operate in conjunction with an existing oil, gas, or electric unit, to provide complete central heating in medium sized well- insulated homes. Before installing be sure unit is properly sized for the intended application. Warranty does not cover misapplication of unit.

Applicable Standards

The KERR TW2000 Wood-Fired Boiler must be installed in accordance with the requirements of the National Fire Protection Association codes, the Canadian Heating, Ventilation and Air Conditioning Code, The National Board of Fire Underwriters, and the C.S.A. Standards for solid fuel burning equipment as outlined in B365-01. In all cases consult your local authorities and fire insurance company for specific regulations.

2.2Uncrating

When you receive your TW2000 Wood-Fired Boiler, check it carefully to ensure that all components are present and in good condition. If there has been any damage or loss in transportation, please notify the carrier and retailer at once.

NOTE: Some parts may be packed inside boiler firebox. Inspect for the following:

1.Firebox/Heat exchanger

2.Poker/Coals rake

3.Cabinet

4.Barometric damper

5.Firebrick (Factory installed in base) See fig. TW-7 for detail.

6.Front insert

7.Overhead baffle

8.Cast door handle assembly

9.Controls package

10.Optional domestic hot water coil

Control Package includes:

1.Dual aquastat, ½” well

2.Single aqustat wt well ½”

3.Damper Motor

4.N/O Zone valve, and fittings

5.Pressure relief valve

6.Tridicator

7.Transformer 120/24V

8.Wiring Harness and Parts

9.Black iron and copper fittings

TW2000

10

10/6/05

Image 11
Contents IMPROPER INSTALLATION WILL RESULT IN INSTALLING BOILER OR LIGHTING FIREABOUT YOUR LOCAL FIRE SAFETY REGULATIONS ALL INSTALLATIONS MUST BE MADE INCONTENTS SAVE THESE INSTRUCTIONS SpecificationsTW2000 SECTION 1 - OPERATING INSTRUCTIONS1.1Introduction 1.2Wood-BurningCREOSOTE 1.3Storage of WoodIN CASE A SERIOUS CREOSOTE FIRE BEGINS 1.4Maximum Solid-FuelCharge 1.5Maintenance1.5.1Cleaning CLEANING PROCEDUREDISPOSAL OF ASHES 1.6Safety10/6/05 1.7Electrical Power FailureTW2000 1.8HOMEOWNER CHECKLIST 10/6/05 SECTION INSTALLATION INSTRUCTIONSTW2000 Applicable Standards SECTION 2 - INSTALLATION INSTRUCTIONS2.1Introduction to Installers 2.2Uncrating2.3Locating the Boiler 10/6/05 2.4.1Combustion Air SupplyTW2000 10/6/05 2.4.2Flue Pipe and ChimneyTW2000 a.The appliances are located on the same story 2.6Plumbing Connections 2.5Clearances10/6/05 2.6.1Free Standing2.6.2Parallel TW200010/6/05 2.8Wiring2.7Control System TW20002.9DEALER INSTRUCTIONS TO THE HOMEOWNER BOILER INSPECTION 2.10Installers Final ChecklistWIRING INSPECTION PIPING INSPECTIONParts List For TW TW-2000Parallel Plumbing Wiring Explanation TW-2 Page Page Page Page Page Page Page Page Page Page Page