1.8HOMEOWNER CHECKLIST

(a)Keep area around TW2000 boiler clean and clear of combustibles.

(b)Use only dry wood. DO NOT burn garbage, gasoline, naphtha engine oil or any other combustible liquid.

(c)Remove ashes as directed.

(d)Watch for soot in smoke pipe – clean regularly.

(e)Clean Boiler heat exchanger regularly.

(f)Be aware of danger due to overfiring unit.

(g)Do not load above maximum loading level (middle of loading door) or overheating may result.

(h)This unit is NOT suitable for automatic stoking.

(i)Load carefully. Do not slam fuel against rear or sides of firebox. This may damage the brick lining. See fig. TW-7 to order and install replacement firebrick.

(j)Always observe the following minimum clearances to combustible materials – Front 48” (1220 mm); one side 6” (152 mm); opposite side and rear 24” (610 mm); and flue pipe 18” (465 mm) and the floor must be non-combustible.

(k)Do not store solid fuel within the above clearances or within the space required for charging and ash removal.

(l)Keep firing door closed and maintain seals in good condition.

(m)Establish a routine for storage of fuel, care of the appliance, and firing techniques.

TW2000

8

10/6/05

Image 9
Contents ABOUT YOUR LOCAL FIRE SAFETY REGULATIONS INSTALLING BOILER OR LIGHTING FIREALL INSTALLATIONS MUST BE MADE IN IMPROPER INSTALLATION WILL RESULT INCONTENTS SAVE THESE INSTRUCTIONS Specifications1.1Introduction SECTION 1 - OPERATING INSTRUCTIONS1.2Wood-Burning TW20001.3Storage of Wood IN CASE A SERIOUS CREOSOTE FIRE BEGINSCREOSOTE 1.5.1Cleaning 1.5MaintenanceCLEANING PROCEDURE 1.4Maximum Solid-FuelChargeDISPOSAL OF ASHES 1.6Safety1.7Electrical Power Failure TW200010/6/05 1.8HOMEOWNER CHECKLIST SECTION INSTALLATION INSTRUCTIONS TW200010/6/05 2.1Introduction to Installers SECTION 2 - INSTALLATION INSTRUCTIONS2.2Uncrating Applicable Standards2.3Locating the Boiler 2.4.1Combustion Air Supply TW200010/6/05 2.4.2Flue Pipe and Chimney TW200010/6/05 a.The appliances are located on the same story 2.6Plumbing Connections 2.5Clearances2.6.2Parallel 2.6.1Free StandingTW2000 10/6/052.7Control System 2.8WiringTW2000 10/6/052.9DEALER INSTRUCTIONS TO THE HOMEOWNER WIRING INSPECTION 2.10Installers Final ChecklistPIPING INSPECTION BOILER INSPECTIONParts List For TW TW-2000Parallel Plumbing Wiring Explanation TW-2 Page Page Page Page Page Page Page Page Page Page Page