Whirlpool ACSIOZ ACS520 warranty Unplug the power cord

Page 22
Manual background

1.Unplug the power cord.

2.Remove the air intake panel. (See “Cleaning the air intake paner on page 20.)

3.Remove 2 Phillips-head screws holding front panel frame in place. Then remove front panel frame the same way you removed the air intake panel.

4.Remove the air conditioner from the window.

5.Remove the 6 slotted hex-head screws along the base of the cabinet (3 per side- as shown).

6.Remove the 1 slotted hex-head screw from the left side of the cabinet (as shown).

7.Holding the cabinet on both sides, carefully

lift cabinet off base.

6crm

6.Wrap the motor, electrical control box and compressor terminal box in plastic film to make sure no water or other liquids get inside. Water or other liquids could damage the insulation and cause serious mechanical problems.

9.Clean and hose out the base, coils and condensate pans. Clean air conditioner at least once a year or more often if the condenser coils and pans collect dirt, sand, leaves, insects or algae. Also, clean the air conditioner if you detect an odor coming from it.

10.Remove plastic film from the motor and electrical parts.

11.Replace cabinet over base and tighten all screws.

12.Reinstall air conditioner in the window.

13.Replace the air intake panel and front panel frame.

14.Plug in the power cord.

NOTE: It is a good idea to wait 24 hours before starting the air conditioner again. Doing so allows time for all areas to dry thoroughly.

The water from rainfall or from normal operation does not harm the motor or electrical parts.

22

Image 22
Contents UseAndCare ANoteToYw IFZZ? Parts And Featuresc&i&F&~ If You Need $$$=F~ Warranty lnstakrtionThank you for buying a WhirlpooP appliance Your safety is important to usA Note To You is toll-free,24 hours a dayImportant safety instructions Help us help youROIlbOVdO air lilb PartsAnd FeaturesCOIIBOICOlltTOl Meeting electrical requirements Installing Your Air CondiiionerReceptacle wiring In ThisElectrical Preparing for installationInstallation tips connectionIn~tdatkm kit contenta APlatform 20’KI illcha Installing in a sliding windowl 40 inches maximum height heightProper Dammge Hazard Alternate screw bc8Uon PI&form IMina on atool bbOutside odgo l.Preudown Alternate window jamb applications Installing in a casement windowFeeten eiding NOTE Do not push or pull on the air direction louvers 13.Drill two %-inchdiameter pilot holee in the top window jamb in line with the partially plugged holes in the panel frame. Secure the panel frame to the window jamb wfth two #8-32x %-inch self-threadingscrews. lf additional holding is necessary, two screws may be used on the sides of the panel frame as well Starting your air conditioner Operating Your Air ConditionerIn This Section PmPW Using the exhaust vent control Cooling at low outside temperaturesAdjusting the air direction louvers Conditioner Cleaning the air intake panelCaring For Your In ThisCleaning the air filter Performing annual maintenance1.Unplug the power cord Understanding normal operating sounds Saving energy1. Before calling for assistance If You Need Assistance Orservice 2. lf you need assistance 3.If you need service4.If you need FSP replace- ment parts vvHlF?LPooc Room Air Conditioner Warranty