Electrical Requirements
Continued
Fire Hazard
Do not use an extension cord.
Doing so can result in death, fire, or electrical shock.
Electrical Shock Hazard
Plug into a grounded three prong outlet. Do not remove ground prong.
Do not use an adapter.
Do not fuse neutral or grounding circuit.
Do not use air conditioner with front panel removed.
Failure to follow these instructions can result in death, electrical shock, or serious injury.
Sprang
groundlng
Plug
115volt modelswith amperes
upthrough7.5 -
Receptacle wiring
Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.
Electrical requirements
A 115 volt (103.5 min., 126.5 max.), 60 Hz, AC only, 15 ampere fused electrical supply is required (time delay fuse or time delay circuit breaker required). It is required that a separate circuit, serving only this air conditioner, be provided.
Electrical connection
Electrical ground is required on this air conditioner.
Recommended grounding method
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a