CC408 Operators Guide 22. Partitioning

EN 17

22. Partitioning

You can partition or split the Solution 880 Control Panel into two individual areas. You can operate both areas from one Master Partitioned codepad or from separate area addressable codepads.

22.1Master Partitioned Codepad Indicators

Figure 6: Master Partitioned Codepad

The indicators on a Master Partitioned codepad are configured into four groups. The following paragraphs describe the indicators.

22.1.1Zone Indicators

The zone indicators (1 to 8) display the status of each zone. These zones belong to the area whose AREA DISPLAY indicator is lit. If a ZONE indicator is lit, that zone is unsealed. If a ZONE indicator is not lit, that zone is sealed.

22.1.2Area On/Off Indicators

The group of four AREA ON/OFF DISPLAY indicators show the status of each area. If an indicator is lit, that area is armed. If the indicator is not lit, that area is disarmed.

22.1.3Area Display Indicators

A group of four AREA DISPLAY indicators determine the area to which the displayed zones belong.

22.1.4Status Indicators

This group of four indicators shows the following:

AUX Indicator

The AUX indicator displays when the system is using the telephone line to communicate to the receiving party.

The AUX indicator flashes in conjunction with the PARTIAL indicator to show successful entry into any programming mode. For example, this occurs when you are using Master Code functions.

Mains Indicator

This indicator displays the status of the AC mains supply. The indicator lights steadily when the AC is normal and flashes when there is an AC supply failure.

Fault Indicator

This indicator displays the status of the system’s fault register. If the FAULT indicator flashes when the system detects a fault that has not yet been acknowledged. If the indicator lights steadily, the fault has been acknowledged.

Partial Indicator

This indicator shows whether an area is armed in STAY Mode 1. If the PARTIAL indicator is lit, the area is armed in STAY Mode 1. If the indicator is not lit, no areas are armed in STAY Mode 1. When isolating zones, the PARTIAL indicator flashes to indicate that you are in the isolate mode. The PARTIAL indicator also flashes in conjunction with the AUX indicator to indicate successful entry into any programming mode (for example, when using Master Code functions).

22.2Operating From A Master Partitioned Codepad

If you have a partitioned system with a Master Partitioned codepad installed, operating procedures described throughout this guide are the same with one exception. All operations are relative to the area whose AREA DISPLAY indicator is illuminated at the time.

Example

When the AREA DISPLAY indicator number 2 is lit, all operations performed affect only Area 2. To perform operations in another area, you must move the AREA DISPLAY illuminator to the desired area.

To Move From One Area To The Next

Press the AWAY button.

The area display indicator moves to the next area. Repeat until the desired indicator is lit.

22.3Operating From Area Addressable Codepads

If you have a partitioned system with Area Addressable codepads, the operating procedures described throughout this guide are the same. Refer to 16. Codepad ID/Buzzer Tone Change on page 14 to determine the area to which a particular codepad belongs.

Bosch Security Systems 5/04 920050O.OG.112

Image 17
Contents Operators Guide CC408Bosch Security Systems 5/04 920050O.OG.112 Copyright NoticeNew Zealand Telepermit Notes Contents Tables Features SpecificationsSpecifications IntroductionZone Indicators Codepad IndicatorsAway Indicator Stay IndicatorArming the System Arming in Stay Mode Arming in Away ModeUser Codes Disarming the SystemDuress Alarm AlarmsPanic Alarm Radio Transmitter OperationsIsolating Zones Setting the Date and TimeSystem Faults Fault Analysis ModeFault Descriptions AC FailTelco Disarm Sequence Telco Arm/Disarm Sequence Call Forward On/OffTelco Arm Sequence Testing Reset Latching Outputs Turning Outputs On/Off Codepad ID/Buzzer Tone ChangeRemote Arming By Telephone Day AlarmEvent Memory Recall Domestic Dialling Disable Domestic DiallingAcknowledging Domestic Calls Programming Domestic Telephone NumbersPartitioning Master Partitioned Codepad IndicatorsOperating From a Master Partitioned Codepad Operating From Area Addressable CodepadsSubscriber ID Number Basic Pager ReportingZone Status Zone Status Display Descriptions678 01200000 9000 Arms or disarms Glossary of TermsOn the same telephone line ModeMode. In Australia, this feature is called Call Forward Service Notes Installation NotesZone Description Isolated Day Alarm Stay Mode Enabled ZoneUser Code Names User Code Bosch Security Systems 5/04 920050O.OG.112Arming Options Entry/Exit TimesOutput Descriptions Isolating MethodIndex Unsealed User Codes CC408 Operators Guide Notes Bosch Security Systems S1920050 Issue 112 4998152467B