Bosch Appliances nbn-932 installation manual Alarm and relay connector, Pin Alarm socket

Page 23

DinionHD 1080p HDR

Installation en 23

 

 

5.5Alarm and relay connector

Alarm

4

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 mm

 

 

 

 

 

 

 

 

 

 

(0.2 in)

1

2

3

 

 

 

 

 

Figure 5.5

Alarm and relay connector pins

 

 

 

 

 

 

 

 

Pin

 

Alarm socket

 

 

 

 

 

 

 

 

1

 

Alarm in 1

 

 

 

 

 

 

 

 

2

 

Alarm in 2

 

 

 

 

 

 

 

 

3

 

Relay out contact 1

 

 

 

 

 

 

 

 

4

 

Ground

 

 

 

 

 

 

 

 

5

 

Ground

 

 

 

 

 

 

 

 

6

 

Relay out contact 2

 

 

 

 

 

 

 

 

 

Max. wire diameter AWG 22-28 for both stranded and solid; cut back 5 mm (0.2 in) of insulation.

Alarm output relay switching capability: Max voltage 30VAC or +40 VDC. Max 0.5 A continuous, 10 VA.

Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled with 22 kOhm pull-up to +3.3 V.

Alarm in: configurable as active low or active high.

Max. 42 V allowed between camera ground and each of the

relay pins.

Use the alarm input to connect external alarm devices such as door contacts or sensors. A zero potential make-contact or switch can be used as the actuator (use a bounce-free contact system).

Use the alarm relay output for switching external devices such as lamps or sirens.

Bosch Security Systems

Installation Manual

AM18-Q0614 v1.0 2012.03

Image 23
Contents DinionHD 1080p HDR Page Table of Contents Troubleshooting InstallationInstall Wizard Camera configurationSafety precautions SafetyImportant safety instructions Grounding Connection in applicationsFCC & Ices Information Resolve Radio-TV Interference Problems. This booklet isFCC & Ices compliance Disclaimer MicroSD cardsUL certification Bosch notices Copyrights Introduction FeaturesOverview of functions System InformationAudio Encryption Bosch Recording Station Operation with external systemsBosch Video Management System Bosch Video ClientSystem requirements PlanningUnpacking Lens mounting InstallationPin DC iris lens 20 UNC Mounting the cameraNetwork connection Network and power connectorEarth Power connectorPin Alarm socket Alarm and relay connectorAudio connectors Audio connectorsInserting an microSD card Local storageVideo service monitor connector Video service monitor connectorPin Data socket Data connectorUsing the camera install wizard Install WizardAdjustment procedure En Install Wizard DinionHD 1080p HDR User modes Camera configurationReset button Day/Night switching Protected network Browser connectionFunction test TroubleshootingMalfunction Possible causes Solution Resolving problemsLivepage Functions For example 192.168.0.80/version Customer serviceData Terminal MaintenanceTesting the network connection Communication with Terminal ProgramAssigning an IP Address Configuring the TerminalCommand Inputs Additional Parameters RebootRepairs Specifications Technical DataIP, IBP, Ibbp Page Bosch Security Systems