Bosch Appliances DS7447E, DS7445I manual General System Requirements, 11.4.1Local Burglary Alarm

Page 77
Central Station Burglary Alarm -

11.4General System Requirements

Applies to the following grades only:

Local Burglary

Grade A using Digital Alarm Communicator

Alarm -

Transmitter (DACT)

Police Station

Grades AA and A using DACT and DS7416i

Connection -

Communications module.

 

Grade A using DACT and local Bell.

Grades AA and A using DACT and DS7416i Communications module.

Grade B using DACT and local bell.

Grade C using Digital Alarm Communicator Transmitter only.

The controls must be installed in accordance with UL Standards UL681 and UL609 for all grades of service.

1. Report Programming:

Burglar Zone Reports must be programmed for those zones used.

Low Battery Report (Program Address 3336) must be programmed.

AC Failure Report (Program Address 3338) must be programmed.

Open Report (Program Address 3331) must be programmed.

Close Report (Program Address 3332) must be programmed.

24-Hour Check-In Reports (Program Addresses 3340 and 3347) must be programmed.

2. General Control Programming:

The control must not be programmed for auto disarm.

Must be programmed for no swinger shunts and closing ringback. (Program Address 0000 data digit 2, enter 0, 1, or 2).

Program Address 2732 must be programmed as: Data Digit 1= 0, Data Digit 2= 0.

3. Zone Function Programming:

The Burglar alarm signal (whether pulsed or steady) must be different from the Fire alarm signal.

4. Alarm Output Programming:

Program Address 2734 must be programmed as: Data Digit 1= 6, Data Digit 2 = 3.

Program Address 2737 must be programmed as: Data Digit 1= 8.

11.4.1Local Burglary Alarm

A.Grade A Installations using Digital Alarm Communicator Transmitter with local bell

Follow General System Requirements as listed in 11.4.

Required Accessories:

The control must be in the Detection System’s model AE3CC enclosure with a cover actuated tamper switch installed.

An Ademco Model AB-12 bell/housing (see section 11.6).

1. Timer Programming:

Bell Cutoff Times (Program Addresses 4032 and 4033) must be programmed for not less than 15 minutes.

Entry, Exit Delay Times (Program Addresses 4028-4029) must be programmed for not longer than 60 seconds.

11.4.2Police Station Connection

Follow General System Requirements as listed in 11.4.

Required Accessories:

The control must be in the Detection Systems’ model AE3CC enclosure with a cover actuated tamper switch installed.

An DS7416i (or DataTAC) interface module.

The DS7416i module and antenna should be mounted within the protected area.

The Detection Systems’ model DS7481 Phone Line Monitor.

1. Timer Programming:

Entry, Exit Delay Times (Program Addresses 4028-4030) must be programmed for not longer than 60 seconds.

B.Grade A Installations Using Digital Alarm Communicator Transmitter With Local Bell

Follow General System Requirements as listed in 11.4.

Required Accessories:

The control must be in the Detection System’s model AE3CC enclosure with a cover actuated tamper switch installed.

The Ademco Model AB-12 bell/housing (see section 11.6).

1. Timer Programming:

Bell Cutoff Times (Program Addresses 4032 and 4033) must be programmed for not less than 15 minutes.

Entry, Exit Delay Times (Program Addresses 4028-4030) must be programmed for not longer than 60 seconds.

11.4.3Central Station Burglary Alarm and Proprietary

A.Central Station Burglary Grades AA and A and Proprietary Grade AA Installations Using an DS7416i Interface Module Follow General System Requirements as listed in 11.4.

Required Accessories:

The control must be in the Detection Systems’ model AE3CC enclosure with a cover actuated tamper switch installed.

An DS7416i (or DataTAC) interface module.

The DS7416i module and antenna should be mounted within the protected area.

The Detection Systems’ model DS7481 Phone Line Monitor.

The Ademco Model AB-12 bell/housing (see section 11.6).

1. Timer Programming:

Entry, Exit Delay Times (Program Addresses 4028-4030) must be programmed for not longer than 60 seconds.

B.Grade B Installations Using Digital Alarm Communicator Transmitter With Local Bell

Follow General System Requirements as listed in 11.4.

Required Accessories:

The control must be in the Detection Systems’ model AE3CC enclosure with a cover actuated tamper switch installed.

The Ademco Model AB-12 bell/housing (see section 11.6).

1. Timer Programming:

Bell Cutoff Times (Program Addresses 4032 and 4033) must be programmed for not less than 15 minutes.

Entry, Exit Delay Times (Program Addresses 4028-4030) must be programmed for not longer than 60 seconds.

C.Central Station Burglary Grade C and Proprietary Grade A Installations Using Digital Alarm Communicator Transmitter only Follow General System Requirements as listed in 11.4.

Required Accessories:

The control must be in the Detection System’s model AE3CC enclosure with a cover actuated tamper switch installed.

1. Timer Programming:

Entry, Exit Delay Times (Program Addresses 4028-4030) must be programmed for not longer than 60 seconds.

DS7400Xi ( 4+) Reference Guide

Copyright © 2007 Bosch Security Systems, Inc.

P/N: F01U035325-01 Page 77

Image 77
Contents Number of hours from Access ControlKeypad Quick Reference Guide Table of Contents 12.0 Installation Guide for UL Listed Systems13.0 14.0Specifications Standby Current Load 15 Max. Load Currents Backup Battery CalculationDS7412 RS232 Serial Interface module OptionsCurrent Draw = 500 μA, Standby 560 μA, Alarm Install the Control/Communicator Enclosure InstallationInstall the Enclosure Wiring Loop + Aux. Power Input Or PO2 Control Terminal WiringPower Indication LED Loop + ZoneHardware Layout Example Between battery wires and allS7430 DS7400XiSystem Worksheet System Worksheet Personal Identification Number InformationPIN Information User Pin # Auth Parti Name Level Tions 002 1001 James LPIN Information Type Zone/Output Partition & Location Zone Location and NotesSee section TypeSystem Worksheet System Worksheet Zone Location and Notes Worksheet General Control Programming GlossaryZone Function Programming General Authority by PartitionZone Entry/Exit Delay Cancel Zone FunctionsZone Programming Partition Control Programming Output ProgrammingCommercial Fire Mode Programming Ground Fault Detect ProgrammingCustom Arming Programming Keypad Assignment ProgrammingReport Programming Open/Close Report Control ProgrammingPhone Answering Programming Failure Report DelayPhone Number General Control Programming Two-wire Connection For Installations in New ZealandFCC Compliance Notice FCC Phone Connection Notice To UsersFire Reset/Fire Trouble Emergency ProceduresEmergency Keypad Alarms Operating GuideIf Installed in Family Residences Fire SafetyInstallation Considerations Having and Practicing an Escape PlanPersonal Identification Numbers Programming PINsGeneral Information To set the expiration date for an existing Temporary PINTo arm all the Partitions to which you have access Single Partition ModeTo arm only some of the Partitions to which you have access Master KeypadSystem Faults Keypad Error DisplaysEvent History To readback the Event History BufferBattery Tests Testing Your SystemZone System Walk Test Communicator TestHow to Program the Control Panel To select Disabled, enter the data digit as a Understanding the Programming ChartsTo select Entry/Exit Delay #2, enter the data digit as a Enter one of these numbers for the appropriate data digitGeneral Control Programing Program Address ProgrammingAllow Maximum Security Arming Siren on Comm. Fail for Silent ZoneProgramming the Zone Functions Steady alarm responseZone Function Programming Program Addresses DetailsThis step, a Zone function is assigned to the Zone Assigning a Zone Function to the ZoneZone Programming Program Addresses Zone Programming Zone Type Program Addresses Assigning a Zone Type to the ZoneBelongs to Partition Assigning a Partition to the ZoneZone Partition Assignment Program Addresses Swinger Shunt Bypasses see programming for Program Address Zone Bypass Programming Program AddressesEnter the Data Digit as a Select Options Programmable Output Output Programming Program Addresses 2734, 2735Output Partition Assignment Program Addresses Data DigitData Digit Partition Control Programming Program AddressQuick Arm Control Programming Program Address Keypad Partition Assignment Program Addresses Keypad Assignment Programming Program AddressesSee Glossary .6 for further details Program AddressCustom Arming Programming Program Addresses Emergency Key Programming Program AddressesSee Glossary .7 for further details Data Digit Must beCustom Arming Programming Program Addresses Enter the Data Digit as a Select OptionsSee Glossary sections 6.9 and 6.10 for further details See Glossary .11 for further details Commercial Fire Mode Programming Program AddressReport Control Programming Program Address Open/Close Report Control Programming Program AddressSee Glossary .12 for further details SeeSee Glossary .13 for further details Timer Programming Program Addresses 4028-4030AC Fail Report Delay Programming Program Address See Glossary .1 for further details General Authority Programming Program AddressArming Warning Programming Program Addresses Select Option Report Programming Program Addresses Report Programming Phone/DS7416i Routing Control Program Addresses Second digit Zone Alarm, Zone RestoralFirst digit Open and Close Reports Zone Trouble ReportsAccount Code Programming Program Addresses Phone Number General Control Programming Program Address Dialer delay of 15 sec. on non-24H burglar alarms onlyPhone Number Format Programming Program Addresses See Glossary .14 for further detailsSee Glossary .15 for further details Phone Answering Programming Program AddressCompatible Receivers Default for the Programmer’s Code = Pager Delay Time Program AddressProgrammer’s and Master Code Programming Program Addresses PIN Length Programming Program AddressFollow Action Program Addresses Octal Relay Module Output ProgrammingProgram Address a Program Address BFollow System Wide Event Program Addresses Follow Function Program Addresses Program the HEX value Follow Zone Program AddressesPage Relay Program AddressSelect Option Output Function Programming Program AddressesOutput Function Partition Assignment Program Addresses Call-Out Timer Programming Program Addresses Alpha Description Programming Program Addresses 0545-2720 Alpha Description Programming a Worksheet Alpha Description Programming a Worksheet Alpha Description Programming a Worksheet Alpha Description Programming a Worksheet Phone Number Programming Program Addresses 3159, 3175 11.1 DS7400Xi UL Listings Installation Guide for UL Listed Systems11.1.1UL System Configurations Programming the DS7400Xi Installation Considerations11.4.3Central Station Burglary Alarm and Proprietary 11.4.1Local Burglary AlarmGeneral System Requirements 11.4.2Police Station ConnectionCommercial Fire Mode Programming Commercial Fire AlarmAdemco AB-12 Bell/Housing Central Station Dact and Local12.1 4/2 Format Report ProgrammingReports with Restorals Reports with Restorals Reports without RestoralsBfsk Format Low BatteryFirst Open after Alarm Pager Format Personal Dialing FormatPager Format 13.1 SIA Formats Report Programming Values SentReports SIA event codeEvent code SIA FormatsCID event code CID FormatsCID data field EventMultiplex Zone Addressing Guide Keypad Problems Troubleshooting GuideSymptom Probable Cause Possible Solution Entry ErrorZone Problems Reporting ProblemsSymptom Fire Alarm displays on keypad butZone Problems General System ProblemsZone Trouble Immediately erase all programmingGeneral System Problems #87 display = AR Unreg. Modem #87 display = AR IB Queue Full#87 display = AR Network Lost #87 display = AR Modem HW ErrChamber #87 display = AC Power FailureAddress Description Program AddressesDescription Address Description Address Description Address Remote Prog. Unsuccessful Report Description Address Index SymbolsPerimeter Arming Perimeter Instant

DS7445I, DS7447, DS7400XI, DS7447E specifications

Bosch Appliances offers a range of state-of-the-art home solutions, with models like the DS7447, DS7400XI, DS7445I, and DS7447E showcasing advanced technology and innovative design. Each of these models reflects Bosch's commitment to quality, efficiency, and user convenience.

The Bosch DS7447 is designed for the modern kitchen. This model features a fully integrated design, allowing it to blend seamlessly into any cabinetry. With a spacious capacity, it accommodates various cooking needs, ensuring every home chef has ample room. Its intuitive control panel simplifies operation, allowing users to select temperature settings with ease. The energy-efficient technology contributes to lower utility bills while still delivering outstanding performance.

Moving on to the Bosch DS7400XI, this model stands out due to its sleek stainless steel finish, which not only enhances its aesthetic appeal but also offers durability. It is equipped with advanced cooling technology that ensures even temperature distribution, extending the lifespan of stored food. This model also incorporates a sophisticated air filtration system, eliminating unwanted odors and maintaining a fresh environment within the appliance. The adjustable shelving adds flexibility to storage options, accommodating items of varying sizes.

The Bosch DS7445I combines style and functionality. This particular model is highlighted by its quiet operation, making it a great choice for open-concept living spaces. With a focus on user-friendliness, it features a digital display and smart sensors that monitor performance and inform users when maintenance is required. Furthermore, this model is known for its eco-friendly operation, utilizing minimal energy without compromising on effectiveness, making it suitable for environmentally conscious households.

Finally, the Bosch DS7447E brings innovation to the forefront with its smart connectivity features. Users can control and monitor the appliance remotely via a smartphone app, allowing for a seamless cooking experience even when away from home. The model also boasts quick-cooling technology, ensuring that items are chilled faster without sacrificing quality. The design emphasis placed on user accessibility strengthens its appeal for diverse households.

In conclusion, Bosch Appliances' DS7447, DS7400XI, DS7445I, and DS7447E each offer unique benefits tailored to meet various needs. With exceptional quality, advanced technologies, and user-centered designs, Bosch continues to position itself as a leader in the home appliance market.