Troubleshooting the Electronic Ignition System

Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position.

Important: Valve system troubleshooting should only be accomplished by a qualified service technician.

 

Symptom

Possible causes

Corrective action

 

 

 

 

 

1.

Nothing happens when

A. Low voltage/or bad lead

Check voltage on AC terminals of module an/or batteries. The value should be

 

ON/OFF switch is turned

wires.

around 2.7 to 3.2 VAC. Confirm that wire connections are secure.

 

on (pilot does not spark).

 

 

 

 

 

B. Damaged igniter wire.

Check for visible cracked casing, cuts, etc.

 

 

 

 

 

 

 

 

 

 

 

C. Damaged pilot assembly.

Check pilot assembly for visibly broken spark electrode, etc.

 

 

 

 

 

 

 

 

D. Batteries Low

Check voltage on D.C. terminal of batteries. The value should be around 3.0V

 

 

 

 

2.

The main burner does

A. No fuel supply.

Ensure that the gas supply is turned on.

 

not light and the igniter

 

 

 

B. Loose sensor wire.

Ensure sensor wire connection is secure.

 

is sparking.

 

 

 

 

 

 

 

 

C. Lose wires to valve.

Ensure black, green and orange wires connection is secure to valve.

 

 

 

 

 

 

 

 

D. Loose wires to ignition

Ensure black sensor wire (S) and black igniter wire (I) is secure to ignition

 

 

 

module.

module.

 

 

 

 

 

 

 

 

E. Air in the gas line.

Purge gas line of air.

 

 

 

 

 

 

 

 

F. Low voltage.

Test voltage at AC terminals of module and/or batteries. It should be around

 

 

 

 

2.7 to 3.2 VAC.

 

 

 

 

3.

The main burner come

A. Gas supply is turned

Turned gas supply to "ON".

 

"ON" but then go "OFF".

"OFF".

 

 

 

 

 

 

 

 

 

B. Loose wire connection on

Check wire connection.

 

 

 

valve or ignition module.

 

 

 

 

 

 

 

 

 

C. Flame does not engulf

Check location of sensor.

 

 

 

flame sensor.

 

 

 

 

 

 

 

 

 

D. Obstructed vent system.

Check vent system for obstructions.

 

 

 

 

4.

The log and glass soot.

A. Flame impingement on

Check for proper log placement.

 

 

 

the log.

 

 

 

 

 

 

 

 

 

B. Improper air shutter

Check for proper air shutter openings.

 

 

 

opening.

 

 

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Image 22
Contents Ment où vous vous trouvez Gaz, appelez le service dos incendiesDo not light any appliance Du fournisseurTable of Contents Burn-in Period Gas Controls/Control Compartment AccessReinstalling Control Compartment Door Operation and care of your applianceInch Pipe Nipple Gas Flex Line Valve Piezo Variable Flame Height AdjustmentElectronic Appliances SIT MillivoltSee Maintenance Schedule, MaintenanceImportant Always verify proper operation after servicing Removing Glass Enclosure Panels Front Glass Enclosure Panel, Removal and InstallationSee Figure Firebox Accessories / Parts Install Volcanic STONE, Glowing Embers and LogsPlacement of Logs Volcanic StoneSLDVT-35 Log Placement Catalog Number for the entire log set H7244Left Rear SLDVT-40 Log PlacementCatalog Number for the entire log set H7245 BracketBurner Air Shutter Adjustment Procedure Burner AdjustmentsAir Shutter Adjustment Guidelines Flame Appearance and sootingReplacement parts Burner Air Shutter AdjustmentWarranty Product reference informationWiring Diagrams Accessory Components Product Reference Information Accessory Components Style View Screen Doors Polished Brass & Brushed Stainless 2-Piece Door Frame KitsAccessory Components Lighting Instructions For Your Safety Read Before LightingLighting Instructions Millivolt GAS Valve To Turn OFF GAS to ApplianceInstructions D’ALLUMAGE Vanne GAZ Millivolt Instructions DallumageWhat to do if YOU Smell GAS Lighting Instructions ElectronicTo shut off Instructions D’ALLUMAGE Instructions D’ALLUMAGE ElectronicPour Éteindre L’APPAREIL Manual. Do not touch or attempt to clean glass Maintenance ScheduleMaintenance Task Accomplishing Person Procedure While hotTroubleshooting Symptom Possible Causes Corrective ActionCheck wire connection Symptom Possible causes Corrective actionNothing happens when Low voltage/or bad lead Batteries LowGas Controls SIT Millivolt Gas Controls Dexen ElectronicDexen Valve Assembly SIT Valve24 P/N 506010-01 REV. N/C 08/2008